Year |
Citation |
Score |
2015 |
Hefny MS, Rudan JF, Ellis RE. Computer-assisted hip resurfacing planning using Lie group shape models. International Journal of Computer Assisted Radiology and Surgery. 10: 707-15. PMID 25930713 DOI: 10.1007/s11548-015-1209-y |
0.706 |
|
2015 |
Hefny MS, Okada T, Hori M, Sato Y, Ellis RE. A liver atlas using the special Euclidean group Lecture Notes in Computer Science (Including Subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics). 9350: 238-245. DOI: 10.1007/978-3-319-24571-3_29 |
0.668 |
|
2014 |
Hefny MS, Rudan JF, Ellis RE. A matrix lie group approach to statistical shape analysis of bones. Studies in Health Technology and Informatics. 196: 163-9. PMID 24732500 DOI: 10.3233/978-1-61499-375-9-163 |
0.7 |
|
2013 |
Hefny MS, Dickinson AW, Giles AE, Wood GC, Ellis RE. The aspherical human hip: implication for early osteoarthritis. Studies in Health Technology and Informatics. 184: 195-201. PMID 23400155 DOI: 10.3233/978-1-61499-209-7-195 |
0.694 |
|
2013 |
Hefny MS, Ellis RE. A statistical shape model of femoral head-neck cross sections using principal tangent components Proceedings - International Symposium On Biomedical Imaging. 89-92. DOI: 10.1109/ISBI.2013.6556419 |
0.707 |
|
2011 |
Fowler S, Hefny MS, Chen EC, Ellis RE, Mercer D, Jalink D, Samis A, Hookey LC. A prospective, randomized assessment of a spatial orientation device in natural orifice transluminal endoscopic surgery. Gastrointestinal Endoscopy. 73: 123-7. PMID 21184877 DOI: 10.1016/J.Gie.2010.09.013 |
0.711 |
|
2010 |
Hefny MS, Ellis RE. Wavelet-based variational deformable registration for ultrasound 2010 7th Ieee International Symposium On Biomedical Imaging: From Nano to Macro, Isbi 2010 - Proceedings. 1017-1020. DOI: 10.1109/ISBI.2010.5490162 |
0.696 |
|
2009 |
Fowler S, Chen E, Hefny M, Ellis R, Mercer D, Jalink D, Samis A, Hookey L. A Prospective Randomized Assessment of a Spatial Orientation Device in Natural Orifice Translumenal Endoscopic Surgery (NOTES) American Journal of Gastroenterology. 104: S534. DOI: 10.14309/00000434-200910003-01420 |
0.704 |
|
2008 |
Hefny M, Abolmaesumi P, Karimaghaloo Z, Gobbi DG, Ellis R, Fichtinger G. Quantification of edematic effects in prostate brachytherapy interventions. Medical Image Computing and Computer-Assisted Intervention : Miccai ... International Conference On Medical Image Computing and Computer-Assisted Intervention. 11: 493-500. PMID 18982641 DOI: 10.1007/978-3-540-85990-1_59 |
0.695 |
|
2007 |
Estépar RS, Stylopoulos N, Ellis R, Samset E, Westin CF, Thompson C, Vosburgh K. Towards scarless surgery: an endoscopic ultrasound navigation system for transgastric access procedures. Computer Aided Surgery : Official Journal of the International Society For Computer Aided Surgery. 12: 311-24. PMID 18066947 DOI: 10.3109/10929080701746892 |
0.349 |
|
2007 |
Hookey LC, Ellis R. Natural orifice translumenal endoscopic surgery (NOTES): what are we getting into? Canadian Journal of Gastroenterology = Journal Canadien De Gastroenterologie. 21: 423-4. PMID 17637942 DOI: 10.1155/2007/109878 |
0.327 |
|
2006 |
Wang LI, Greenspan M, Ellis R. Validation of bone segmentation and improved 3-D registration using contour coherency in CT data. Ieee Transactions On Medical Imaging. 25: 324-34. PMID 16524088 DOI: 10.1109/Tmi.2005.863834 |
0.302 |
|
1996 |
Ellis R, Toksvig-Larsen S, Marcacci M, Caramella D, Fadda M. Use of a biocompatible fiducial marker in evaluating the accuracy of computed tomography image registration. Investigative Radiology. 31: 658-667. PMID 8889655 DOI: 10.1097/00004424-199610000-00008 |
0.313 |
|
Show low-probability matches. |