Year |
Citation |
Score |
2023 |
Thamatam N, Ahn J, Chowdhury M, Sharma A, Gupta P, Marr LC, Nazhandali L, Agah M. A MEMS-enabled portable gas chromatography injection system for trace analysis. Analytica Chimica Acta. 1261: 341209. PMID 37147055 DOI: 10.1016/j.aca.2023.341209 |
0.347 |
|
2021 |
Gholizadeh A, Chowdhury M, Agah M. Ionic liquid stationary phase coating optimization for semi-packed microfabricated columns. Journal of Chromatography. A. 1647: 462144. PMID 33957352 DOI: 10.1016/j.chroma.2021.462144 |
0.3 |
|
2020 |
Gholizadeh A, Chowdhury M, Agah M. Parallel Ionic Liquid Semi-Packed Microfabricated Columns for Complex Gas Analysis. Analytical Chemistry. PMID 32640785 DOI: 10.1021/Acs.Analchem.0C01721 |
0.469 |
|
2020 |
Kikkeri K, Kerr BA, Bertke AS, Strobl JS, Agah M. Passivated-Electrode Insulator-based Dielectrophoretic Separation of Heterogeneous Cell Mixtures. Journal of Separation Science. PMID 31991043 DOI: 10.1002/Jssc.201900553 |
0.342 |
|
2019 |
Ghassemi P, Ren X, Foster BM, Kerr BA, Agah M. Post-enrichment circulating tumor cell detection and enumeration via deformability impedance cytometry. Biosensors & Bioelectronics. 111868. PMID 31767345 DOI: 10.1016/J.Bios.2019.111868 |
0.312 |
|
2019 |
Nam W, Ren X, Tali SAS, Ghassemi P, Kim I, Agah M, Zhou W. RI-Insensitive Nanolaminated SERS Substrates for Label-free Raman Profiling and Classification of Living Cancer Cells. Nano Letters. PMID 31525057 DOI: 10.1021/Acs.Nanolett.9B02864 |
0.308 |
|
2019 |
Ren X, Ghassemi P, Strobl JS, Agah M. Biophysical phenotyping of cells via impedance spectroscopy in parallel cyclic deformability channels. Biomicrofluidics. 13: 044103. PMID 31341524 DOI: 10.1063/1.5099269 |
0.301 |
|
2019 |
Chan R, Agah M. Semi-Packed Gas Chromatography Columns With Density Modulated Pillars Journal of Microelectromechanical Systems. 28: 114-124. DOI: 10.1109/Jmems.2018.2881532 |
0.459 |
|
2018 |
Regmi BP, Agah M. Micro Gas Chromatography: An Overview of Critical Components and Their Integration. Analytical Chemistry. PMID 30359512 DOI: 10.1021/Acs.Analchem.8B01461 |
0.44 |
|
2018 |
Regmi BP, Chan R, Atta A, Agah M. Ionic liquid-coated alumina-pretreated micro gas chromatography columns for high-efficient separations. Journal of Chromatography. A. 1566: 124-134. PMID 30017088 DOI: 10.1016/J.Chroma.2018.06.058 |
0.451 |
|
2018 |
Ren X, Foster B, Ghassemi P, Strobl JS, Kerr BA, Agah M. Entrapment of Prostate Cancer Circulating Tumor Cells with a Sequential Size-Based Microfluidic Chip. Analytical Chemistry. PMID 29790741 DOI: 10.1021/Acs.Analchem.8B01134 |
0.329 |
|
2018 |
Kikkeri K, Riquelme Breazeal MV, Ren X, Pruden A, Agah M. A Monolithic Dielectrophoresis Chip With Impedimetric Sensing for Assessment of Pathogen Viability Journal of Microelectromechanical Systems. 27: 810-817. DOI: 10.1109/Jmems.2018.2860926 |
0.339 |
|
2017 |
Ren X, Ghassemi P, Babahosseini H, Strobl JS, Agah M. Single-Cell Mechanical Characteristics Analyzed by Multiconstriction Microfluidic Channels. Acs Sensors. 2: 290-299. PMID 28723132 DOI: 10.1021/Acssensors.6B00823 |
0.312 |
|
2017 |
Regmi BP, Chan R, Agah M. Ionic liquid functionalization of semi-packed columns for high-performance gas chromatographic separations. Journal of Chromatography. A. PMID 28662852 DOI: 10.1016/J.Chroma.2017.06.050 |
0.5 |
|
2017 |
Hosseini Y, Soltanian-Zadeh S, Srinivasaraghavan V, Agah M. A Silicon-Based Porous Thin Membrane as a Cancer Cell Transmigration Assay Journal of Microelectromechanical Systems. 26: 308-316. DOI: 10.1109/Jmems.2016.2618774 |
0.359 |
|
2017 |
Shakeel H, Agah M. High density semipacked separation columns with optimized atomic layer deposited phases Sensors and Actuators B: Chemical. 242: 215-223. DOI: 10.1016/J.Snb.2016.11.046 |
0.42 |
|
2015 |
Srinivasaraghavan V, Strobl J, Agah M. Microelectrode bioimpedance analysis distinguishes basal and claudin-low subtypes of triple negative breast cancer cells. Biomedical Microdevices. 17: 80. PMID 26216474 DOI: 10.1007/S10544-015-9977-2 |
0.303 |
|
2015 |
Nakidde D, Zellner P, Alemi MM, Shake T, Hosseini Y, Riquelme MV, Pruden A, Agah M. Three dimensional passivated-electrode insulator-based dielectrophoresis. Biomicrofluidics. 9: 014125. PMID 25784964 DOI: 10.1063/1.4913497 |
0.328 |
|
2015 |
Akbar M, Shakeel H, Agah M. GC-on-chip: integrated column and photoionization detector. Lab On a Chip. 15: 1748-58. PMID 25673367 DOI: 10.1039/C4Lc01461H |
0.484 |
|
2015 |
Zellner P, Shake T, Hosseini Y, Nakidde D, Riquelme MV, Sahari A, Pruden A, Behkam B, Agah M. 3D Insulator-based dielectrophoresis using DC-biased, AC electric fields for selective bacterial trapping. Electrophoresis. 36: 277-83. PMID 25257669 DOI: 10.1002/Elps.201400236 |
0.315 |
|
2015 |
Akbar M, Shakeel H, Agah M. An integrated chromatographychip for rapid gas separation and detection Proceedings of the Ieee International Conference On Micro Electro Mechanical Systems (Mems). 2015: 771-774. DOI: 10.1109/MEMSYS.2015.7051072 |
0.383 |
|
2015 |
Akbar M, Restaino M, Agah M. Chip-scale gas chromatography: From injection through detection Microsystems & Nanoengineering. 1. DOI: 10.1038/Micronano.2015.39 |
0.785 |
|
2015 |
Shakeel H, Wang D, Heflin JR, Agah M. Improved self-assembled thiol stationary phases in microfluidic gas separation columns Sensors and Actuators, B: Chemical. 216: 349-357. DOI: 10.1016/J.Snb.2015.03.107 |
0.406 |
|
2015 |
Garg A, Akbar M, Vejerano E, Narayanan S, Nazhandali L, Marr LC, Agah M. Zebra GC: A mini gas chromatography system for trace-level determination of hazardous air pollutants Sensors and Actuators, B: Chemical. 212: 145-154. DOI: 10.1016/J.Snb.2014.12.136 |
0.452 |
|
2015 |
Narayanan S, Rice G, Agah M. Characterization of a micro-helium discharge detector for gas chromatography Sensors and Actuators, B: Chemical. 206: 190-197. DOI: 10.1016/J.Snb.2014.09.014 |
0.363 |
|
2014 |
Akbar M, Narayanan S, Restaino M, Agah M. A purge and trap integrated microGC platform for chemical identification in aqueous samples. The Analyst. 139: 3384-92. PMID 24837988 DOI: 10.1039/C4An00254G |
0.774 |
|
2014 |
Shakeel H, Wang D, Heflin JR, Agah M. Width-modulated microfluidic columns for gas separations Ieee Sensors Journal. 14: 3352-3357. DOI: 10.1109/Jsen.2014.2326593 |
0.379 |
|
2014 |
Garg A, Akbar M, Narayanan S, Nazhandali L, Agah M. Zebra GC: A fully integrated micro gas chromatography system Proceedings of Ieee Sensors. 2014: 673-676. DOI: 10.1109/ICSENS.2014.6985088 |
0.362 |
|
2014 |
Shakeel H, Rice GW, Agah M. Semipacked columns with atomic layer-deposited alumina as a stationary phase Sensors and Actuators, B: Chemical. 203: 641-646. DOI: 10.1016/J.Snb.2014.06.017 |
0.393 |
|
2014 |
Narayanan S, Rice G, Agah M. A micro-discharge photoionization detector for micro-gas chromatography Microchimica Acta. 181: 493-499. DOI: 10.1007/S00604-013-1146-9 |
0.447 |
|
2013 |
Akbar M, Wang D, Goodman R, Hoover A, Rice G, Heflin JR, Agah M. Improved performance of micro-fabricated preconcentrators using silica nanoparticles as a surface template. Journal of Chromatography. A. 1322: 1-7. PMID 24268363 DOI: 10.1016/J.Chroma.2013.10.083 |
0.368 |
|
2013 |
Shake T, Zellner P, Sahari A, Breazeal MV, Behkam B, Pruden A, Agah M. Embedded passivated-electrode insulator-based dielectrophoresis (EπDEP). Analytical and Bioanalytical Chemistry. 405: 9825-33. PMID 24162823 DOI: 10.1007/S00216-013-7435-7 |
0.329 |
|
2013 |
Wang D, Shakeel H, Lovette J, Rice GW, Heflin JR, Agah M. Highly stable surface functionalization of microgas chromatography columns using layer-by-layer self-assembly of silica nanoparticles. Analytical Chemistry. 85: 8135-41. PMID 23889461 DOI: 10.1021/Ac401080U |
0.371 |
|
2013 |
Zellner P, Shake T, Sahari A, Behkam B, Agah M. Off-chip passivated-electrode, insulator-based dielectrophoresis (OπDEP). Analytical and Bioanalytical Chemistry. 405: 6657-66. PMID 23812879 DOI: 10.1007/S00216-013-7123-7 |
0.309 |
|
2013 |
Alfeeli B, Narayanan S, Moodie D, Zellner P, McMillan M, Hirtenstein D, Rice G, Agah M. Interchannel mixing minimization in semi-packed micro gas chromatography columns Ieee Sensors Journal. 13: 4312-4319. DOI: 10.1109/Jsen.2013.2267795 |
0.77 |
|
2013 |
Nikkhah M, Strobl JS, Srinivasaraghavan V, Agah M. Isotropically etched silicon microarrays for rapid breast cancer cell capture Ieee Sensors Journal. 13: 1125-1132. DOI: 10.1109/Jsen.2012.2227716 |
0.333 |
|
2013 |
Narayanan S, Agah M. Fabrication and characterization of a suspended TCD integrated with a gas separation column Journal of Microelectromechanical Systems. 22: 1166-1173. DOI: 10.1109/Jmems.2013.2255117 |
0.488 |
|
2013 |
Hosseini Y, Zellner P, Agah M. A single-mask process for 3-D microstructure fabrication in PDMS Journal of Microelectromechanical Systems. 22: 356-362. DOI: 10.1109/Jmems.2012.2231402 |
0.346 |
|
2013 |
Akbar M, Agah M. A microfabricated propofol trap for breath-based anesthesia depth monitoring Journal of Microelectromechanical Systems. 22: 443-451. DOI: 10.1109/Jmems.2012.2227949 |
0.438 |
|
2013 |
Shakeel H, Agah M. Self-patterned gold-electroplated multicapillary gas separation columns with MPG stationary phases Journal of Microelectromechanical Systems. 22: 62-70. DOI: 10.1109/Jmems.2012.2213068 |
0.423 |
|
2013 |
Shakeel H, Wang D, Heflin R, Agah M. Width-modulated microgas chromatography separation columns with silica nanoparticles stationary phase Ieee Sensors 2013 - Proceedings. DOI: 10.1109/ICSENS.2013.6688124 |
0.31 |
|
2012 |
Zellner P, Agah M. Silicon insulator-based dielectrophoresis devices for minimized heating effects. Electrophoresis. 33: 2498-507. PMID 22899257 DOI: 10.1002/Elps.201100661 |
0.367 |
|
2012 |
Akbar M, Agah M. A golden micro-trap for anesthetic depth monitoring using human breath samples Proceedings of the Ieee International Conference On Micro Electro Mechanical Systems (Mems). 906-909. DOI: 10.1109/MEMSYS.2012.6170332 |
0.339 |
|
2012 |
Shakeel H, Rice G, Agah M. First reconfigurable MEMS separation columns for micro gas chromatography Proceedings of the Ieee International Conference On Micro Electro Mechanical Systems (Mems). 823-826. DOI: 10.1109/MEMSYS.2012.6170312 |
0.367 |
|
2012 |
Narayanan S, Alfeeli B, Agah M. Two-port static coated micro gas chromatography column with an embedded thermal conductivity detector Ieee Sensors Journal. 12: 1893-1900. DOI: 10.1109/Jsen.2011.2180017 |
0.796 |
|
2012 |
Narayanan S, Agah M. A high-performance TCD monolithically integrated with a gas separation column Proceedings of Ieee Sensors. DOI: 10.1109/ICSENS.2012.6411575 |
0.402 |
|
2012 |
Shakeel H, Agah M. Semipacked separation columns with monolayer protected gold stationary phases for microgas chromatography Proceedings of Ieee Sensors. DOI: 10.1109/ICSENS.2012.6411352 |
0.337 |
|
2012 |
Akbar M, Agah M. A cascaded micro preconcentration approach for extraction of volatile organic compounds in water Proceedings of Ieee Sensors. DOI: 10.1109/ICSENS.2012.6411337 |
0.338 |
|
2012 |
Narayanan S, Agah M. A micro gas chromatography column with an embedded out-of-plane thermal conductivity detector Technical Digest - Solid-State Sensors, Actuators, and Microsystems Workshop. 221-224. |
0.392 |
|
2011 |
Vereb H, Dietrich AM, Alfeeli B, Agah M. The possibilities will take your breath away: breath analysis for assessing environmental exposure. Environmental Science & Technology. 45: 8167-75. PMID 21838235 DOI: 10.1021/Es202041J |
0.725 |
|
2011 |
Nikkhah M, Strobl JS, Schmelz EM, Roberts PC, Zhou H, Agah M. MCF10A and MDA-MB-231 human breast basal epithelial cell co-culture in silicon micro-arrays. Biomaterials. 32: 7625-32. PMID 21764441 DOI: 10.1016/J.Biomaterials.2011.06.041 |
0.304 |
|
2011 |
Alfeeli B, Agah M. Toward handheld diagnostics of cancer biomarkers in breath: Micro preconcentration of trace levels of volatiles in human breath Ieee Sensors Journal. 11: 2756-2762. DOI: 10.1109/Jsen.2011.2160390 |
0.762 |
|
2011 |
Shakeel H, Agah M. High-performance multicapillary gas separation columns with MPG stationary phases Proceedings of Ieee Sensors. 1909-1912. DOI: 10.1109/ICSENS.2011.6127406 |
0.366 |
|
2011 |
Alfeeli B, Narayanan S, McMillan M, Hirtenstein D, Rice G, Agah M. The effect of pillar array in semi-packed micro gas chromatography Proceedings of Ieee Sensors. 1097-1100. DOI: 10.1109/ICSENS.2011.6127373 |
0.351 |
|
2011 |
Alfeeli B, Jain V, Johnson RK, Beyer FL, Heflin JR, Agah M. Characterization of poly(2,6-diphenyl-p-phenylene oxide) films as adsorbent for microfabricated preconcentrators Microchemical Journal. 98: 240-245. DOI: 10.1016/J.Microc.2011.02.006 |
0.731 |
|
2010 |
Strobl JS, Nikkhah M, Agah M. Actions of the anti-cancer drug suberoylanilide hydroxamic acid (SAHA) on human breast cancer cytoarchitecture in silicon microstructures. Biomaterials. 31: 7043-50. PMID 20579727 DOI: 10.1016/J.Biomaterials.2010.05.023 |
0.306 |
|
2010 |
Zareian-Jahromi MA, Agah M. Microfabricated gas chromatography columns with monolayer-protected gold stationary phases Journal of Microelectromechanical Systems. 19: 294-304. DOI: 10.1109/JMEMS.2009.2038936 |
0.334 |
|
2010 |
Narayanan S, Alfeeli B, Agah M. Thermostatted micro gas chromatography column with on-chip thermal conductivity detector for elevated temperature separation Proceedings of Ieee Sensors. 2504-2507. DOI: 10.1109/ICSENS.2010.5690117 |
0.378 |
|
2010 |
Zellner P, Renaghan L, Hasnain Z, Agah M. A fabrication technology for three-dimensional micro total analysis systems Journal of Micromechanics and Microengineering. 20. DOI: 10.1088/0960-1317/20/4/045013 |
0.376 |
|
2010 |
Narayanan S, Nikkhah M, Strob JS, Agah M. Analysis of the passivation layer by testing and modeling a cell impedance micro-sensor Sensors and Actuators, a: Physical. 159: 241-247. DOI: 10.1016/J.Sna.2009.12.036 |
0.314 |
|
2010 |
Alfeeli B, Hogg D, Agah M. Solid-phase microextraction using silica fibers coated with tenax-TA films Procedia Engineering. 5: 1152-1155. DOI: 10.1016/J.Proeng.2010.09.315 |
0.717 |
|
2010 |
Narayanan S, Alfeeli B, Agah M. A micro gas chromatography chip with an embedded non-cascaded thermal conductivity detector Procedia Engineering. 5: 29-32. DOI: 10.1016/J.Proeng.2010.09.040 |
0.782 |
|
2010 |
Alfeeli B, Taylor LT, Agah M. Evaluation of Tenax TA thin films as adsorbent material for micro preconcentration applications Microchemical Journal. 95: 259-267. DOI: 10.1016/J.Microc.2009.12.011 |
0.75 |
|
2009 |
Alfeeli B, Zareian-Jahromi MA, Agah M. Selective micro preconcentration of propofol for anesthetic depth monitoring by using seedless electroplated gold as adsorbent. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2009: 2763-6. PMID 19964594 DOI: 10.1109/IEMBS.2009.5333868 |
0.759 |
|
2009 |
Alfeeli B, Agah M. MEMS-Based selective preconcentration of trace level breath analytes Ieee Sensors Journal. 9: 1068-1075. DOI: 10.1109/Jsen.2009.2025822 |
0.762 |
|
2009 |
Zareian-Jahromi MA, Ashraf-Khorassani M, Taylor LT, Agah M. Design, modeling, and fabrication of MEMS-based multicapillary gas chromatographic columns Journal of Microelectromechanical Systems. 18: 28-37. DOI: 10.1109/Jmems.2008.2007267 |
0.485 |
|
2009 |
Ali S, Ashraf-Khorassani M, Taylor LT, Agah M. MEMS-based semi-packed gas chromatography columns Sensors and Actuators, B: Chemical. 141: 309-315. DOI: 10.1016/J.Snb.2009.06.022 |
0.499 |
|
2008 |
Alfeeli B, Agah M. Micro preconcentrator with embedded 3D pillars for breath analysis applications Proceedings of Ieee Sensors. 736-739. DOI: 10.1109/ICSENS.2008.4716547 |
0.301 |
|
2008 |
Alfeeli B, Ali S, Jain V, Montazami R, Heflin J, Agah M. MEMS-based gas chromatography columns with nano-structured stationary phases Proceedings of Ieee Sensors. 728-731. DOI: 10.1109/ICSENS.2008.4716545 |
0.301 |
|
2008 |
Gantz K, Renaghan L, Agah M. Development of a comprehensive model for RIE-lag-based three-dimensional microchannel fabrication Journal of Micromechanics and Microengineering. 18. DOI: 10.1088/0960-1317/18/2/025003 |
0.344 |
|
2008 |
Alfeeli B, Cho D, Ashraf-Khorassani M, Taylor LT, Agah M. MEMS-based multi-inlet/outlet preconcentrator coated by inkjet printing of polymer adsorbents Sensors and Actuators, B: Chemical. 133: 24-32. DOI: 10.1016/J.Snb.2008.01.063 |
0.796 |
|
2007 |
Reidy S, George D, Agah M, Sacks R. Temperature-programmed GC using silicon microfabricated columns with integrated heaters and temperature sensors. Analytical Chemistry. 79: 2911-7. PMID 17311465 DOI: 10.1021/Ac062148S |
0.402 |
|
2007 |
Agah M, Wise KD. Low-mass PECVD oxynitride gas chromatographic columns Journal of Microelectromechanical Systems. 16: 853-860. DOI: 10.1109/Jmems.2007.893515 |
0.658 |
|
2006 |
Agah M, Lambertus GR, Sacks R, Wise K. High-speed MEMS-based gas chromatography Journal of Microelectromechanical Systems. 15: 1371-1378. DOI: 10.1109/JMEMS.2006.879708 |
0.544 |
|
2005 |
Lu CJ, Steinecker WH, Tian WC, Oborny MC, Nichols JM, Agah M, Potkay JA, Chan HK, Driscoll J, Sacks RD, Wise KD, Pang SW, Zellers ET. First-generation hybrid MEMS gas chromatograph. Lab On a Chip. 5: 1123-31. PMID 16175269 DOI: 10.1039/B508596A |
0.802 |
|
2005 |
Agah M, Wise KD. A fully-dry pecvd-oxynitride process for microgc column fabrication Proceedings of the Ieee International Conference On Micro Electro Mechanical Systems (Mems). 774-777. DOI: 10.1109/MEMSYS.2005.1454044 |
0.513 |
|
2005 |
Agah M, Potkay JA, Lambertus G, Sacks R, Wise KD. High-performance temperature-programmed microfabricated gas chromatography columns Journal of Microelectromechanical Systems. 14: 1039-1050. DOI: 10.1109/Jmems.2005.856648 |
0.763 |
|
2005 |
Agah M, Wise KD. PECVD-oxynitride gas chromatographic columns Technical Digest - International Electron Devices Meeting, Iedm. 2005: 302-305. |
0.56 |
|
2004 |
Lambertus G, Elstro A, Sensenig K, Potkay J, Agah M, Scheuering S, Wise K, Dorman F, Sacks R. Design, fabrication, and evaluation of microfabricated columns for gas chromatography. Analytical Chemistry. 76: 2629-37. PMID 15117208 DOI: 10.1021/Ac030367X |
0.777 |
|
2004 |
Agah M, Lambertus GR, Sacks RD, Wise KD. High-speed MEMS-based gas chromatography Technical Digest - International Electron Devices Meeting, Iedm. 27-30. DOI: 10.1109/Jmems.2006.879708 |
0.644 |
|
2003 |
Agah M, Potkay JA, Driscoll JA, Sacks RD, Kaviany M, Wise KD. Thermal behavior of high-performance temperature programmed microfabricated gas chromatography columns Transducers 2003 - 12th International Conference On Solid-State Sensors, Actuators and Microsystems, Digest of Technical Papers. 2: 1339-1342. DOI: 10.1109/SENSOR.2003.1217021 |
0.743 |
|
2003 |
Potkay JA, Driscoll JA, Agah M, Sacks RD, Wise KD. A high-performance microfabricated gas chromatography column Proceedings of the Ieee Micro Electro Mechanical Systems (Mems). 395-398. |
0.757 |
|
Show low-probability matches. |