Year |
Citation |
Score |
2021 |
Bardo DME, Rubert N. Radial sequences and compressed sensing in pediatric body magnetic resonance imaging. Pediatric Radiology. PMID 34009408 DOI: 10.1007/s00247-021-05097-6 |
0.398 |
|
2021 |
Rubert N, Bardo DME, Vaughn J, Cornejo P, Goncalves LF. Data Quality Assessment for Super-Resolution Fetal Brain MR Imaging: A Retrospective 1.5 T Study. Journal of Magnetic Resonance Imaging : Jmri. PMID 33949725 DOI: 10.1002/jmri.27665 |
0.384 |
|
2019 |
Rubert N, Southard R, Hamman SM, Robison R. Evaluation of low-contrast detectability for iterative reconstruction in pediatric abdominal computed tomography: a phantom study. Pediatric Radiology. PMID 31705156 DOI: 10.1007/S00247-019-04561-8 |
0.4 |
|
2016 |
Rubert N, Szczykutowicz T, Ranallo F. Improvement in CT image resolution due to the use of focal spot deflection and increased sampling. Journal of Applied Clinical Medical Physics. 17: 452-466. PMID 28297344 DOI: 10.1120/jacmp.v17i3.6039 |
0.314 |
|
2016 |
Yang W, Ziemlewicz TJ, Varghese T, Alexander ML, Rubert N, Ingle AN, Lubner MG, Hinshaw JL, Wells SA, Lee FT, Zagzebski JA. Post-procedure Evaluation of Microwave Ablations of Hepatocellular Carcinomas Using Electrode Displacement Elastography. Ultrasound in Medicine & Biology. PMID 27592561 DOI: 10.1016/J.Ultrasmedbio.2016.07.015 |
0.773 |
|
2016 |
Rubert N, Szczykutowicz T, Ranallo F. Improvement in CT image resolution due to the use of focal spot deflection and increased sampling. Journal of Applied Clinical Medical Physics / American College of Medical Physics. 17: 6039. PMID 27167276 DOI: 10.1120/Jacmp.V17I3.6039 |
0.423 |
|
2016 |
Szczykutowicz TP, Rubert N, Belden D, Ciano A, Duplissis A, Hermanns A, Monette S, Saldivar EJ. A Wiki-Based Solution to Managing Your Institution's Imaging Protocols. Journal of the American College of Radiology : Jacr. PMID 26810636 DOI: 10.1016/J.Jacr.2015.10.021 |
0.319 |
|
2015 |
Szczykutowicz TP, Bour RK, Rubert N, Wendt G, Pozniak M, Ranallo FN. CT protocol management: simplifying the process by using a master protocol concept. Journal of Applied Clinical Medical Physics / American College of Medical Physics. 16: 5412. PMID 26219005 DOI: 10.1120/Jacmp.V16I4.5412 |
0.301 |
|
2015 |
Szczykutowicz T, Rubert N, Ranallo F. MO-D-213-06: Quantitative Image Quality Metrics Are for Physicists, Not Radiologists: How to Communicate to Your Radiologists Using Their Language Medical Physics. 42: 3554-3554. DOI: 10.1118/1.4925322 |
0.491 |
|
2015 |
Rubert N, Szczykutowicz T, Ranallo F. SU-E-I-14: Avoiding a Common Pitfall in Performing MTF Measurements with High Resolution Kernels Medical Physics. 42: 3244-3244. DOI: 10.1118/1.4924011 |
0.387 |
|
2015 |
Rubert N, Zagzebski J. SU-D-210-01: Automated Depth of Penetration Measurements for Quality Assurance in Ultrasound Medical Physics. 42: 3221-3221. DOI: 10.1118/1.4923916 |
0.473 |
|
2014 |
Rubert N, Varghese T. Alterations in Ultrasound Scattering Following Thermal Ablation in ex vivo Bovine Liver. Ieee International Ultrasonics Symposium : [Proceedings]. Ieee International Ultrasonics Symposium. 2014: 1904-1907. PMID 26185596 DOI: 10.1109/ULTSYM.2014.0473 |
0.524 |
|
2014 |
Rubert N, Varghese T. Scatterer number density considerations in reference phantom-based attenuation estimation. Ultrasound in Medicine & Biology. 40: 1680-96. PMID 24726800 DOI: 10.1016/J.Ultrasmedbio.2014.01.022 |
0.584 |
|
2014 |
Rubert N, Varghese T. Mean scatterer spacing estimation in normal and thermally coagulated ex vivo bovine liver. Ultrasonic Imaging. 36: 79-97. PMID 24554290 DOI: 10.1177/0161734613511232 |
0.562 |
|
2014 |
Rubert N, Varghese T. The effect of low scatterer number density on ultrasound attenuation estimation Ieee International Ultrasonics Symposium, Ius. 2418-2421. DOI: 10.1109/ULTSYM.2014.0603 |
0.492 |
|
2014 |
Kemmerer JP, Ghoshal G, Oelze ML, Rubert N, Samimi K. Quantitative imaging of temperature elevations in tissues due to thermal therapies Ieee International Ultrasonics Symposium, Ius. 2153-2156. DOI: 10.1109/ULTSYM.2014.0536 |
0.723 |
|
2014 |
Yang W, Alexander M, Rubert N, Ingle A, Lubner M, Ziemlewicz T, Hinshaw JL, Lee FT, Zagzebski JA, Varghese T. Monitoring microwave ablation for liver tumors with electrode displacement strain imaging Ieee International Ultrasonics Symposium, Ius. 1128-1131. DOI: 10.1109/ULTSYM.2014.0277 |
0.794 |
|
2013 |
Rubert N, Varghese T. Coherence of Ultrasound Radiofrequency Echoes from the Liver Estimated Using Multi-Taper Calculation. Proceedings / Ieee International Symposium On Biomedical Imaging: From Nano to Macro. Ieee International Symposium On Biomedical Imaging. 2013: 724-727. PMID 25404995 DOI: 10.1109/ISBI.2013.6556577 |
0.46 |
|
2013 |
Rubert N, Varghese T. Mean scatterer spacing estimation using multi-taper coherence. Ieee Transactions On Ultrasonics, Ferroelectrics, and Frequency Control. 60: 1061-73. PMID 25004470 DOI: 10.1109/Tuffc.2013.2670 |
0.516 |
|
2013 |
Rubert N, Varghese T. SU-E-I-101: Multi Taper Coherence Measurements for Characterizing Scatterer Number Density Medical Physics. 40: 149-149. DOI: 10.1118/1.4814212 |
0.493 |
|
2011 |
McCormick M, Rubert N, Varghese T. Bayesian regularization applied to ultrasound strain imaging. Ieee Transactions On Bio-Medical Engineering. 58: 1612-20. PMID 21245002 DOI: 10.1109/Tbme.2011.2106500 |
0.753 |
|
2011 |
Nam K, Zagzebski J, Rosado-Mendez I, Hall T, Rubert N. TU-G-220-06: Reference Phantom Measurements of Attenuation and Backscatter with Speed of Sound Disparities Medical Physics. 38: 3790-3790. DOI: 10.1118/1.3613265 |
0.334 |
|
2010 |
Rubert N, Bharat S, DeWall RJ, Andreano A, Brace C, Jiang J, Sampson L, Varghese T. Electrode displacement strain imaging of thermally-ablated liver tissue in an in vivo animal model. Medical Physics. 37: 1075-82. PMID 20384243 DOI: 10.1118/1.3301603 |
0.786 |
|
2010 |
Jiang J, Brace C, Andreano A, DeWall RJ, Rubert N, Fisher TG, Varghese T, Lee F, Hall TJ. Ultrasound-based relative elastic modulus imaging for visualizing thermal ablation zones in a porcine model. Physics in Medicine and Biology. 55: 2281-306. PMID 20354279 DOI: 10.1088/0031-9155/55/8/011 |
0.797 |
|
2010 |
Rubert N, Bharat S, DeWall R, Andreano A, Brace C, Jiang J, Sampson L, Zagzebski J, Lee F, Varghese T. TU-E-201C-05: Electrode Displacement Strain Imaging for Monitoring In-Vivo Ablative Therapies Medical Physics. 37: 3405-3405. DOI: 10.1118/1.3469307 |
0.794 |
|
2010 |
Zagzebski J, Rubert N, DeWall R, Varghese T. TU-C-202-02: QA/QC in Diagnostic Ultrasound Imaging Medical Physics. 37: 3388-3389. DOI: 10.1118/1.3469241 |
0.746 |
|
2009 |
Jiang J, Brace C, Andreano A, Dewall R, Rubert N, Fisher T, Varghese T, Lee F, Hall TJ. Elastic Modulus Imaging (EMI) for visualizing thermal ablation zone: Initial experience in a porcine model Proceedings - Ieee Ultrasonics Symposium. DOI: 10.1109/ULTSYM.2009.5441780 |
0.8 |
|
2009 |
Rubert N, Bharat S, Dewall R, Andreano A, Brace C, Jiang J, Sampson L, Zagzebski JA, Lee F, Varghese T. In vivo ultrasound electrode displacement strain imaging Proceedings - Ieee Ultrasonics Symposium. DOI: 10.1109/ULTSYM.2009.5441747 |
0.785 |
|
Show low-probability matches. |