105 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2022 Omecinski KS, Federspiel WJ. Improvement of a Mathematical Model to Predict CO Removal in Hollow Fiber Membrane Oxygenators. Bioengineering (Basel, Switzerland). 9. PMID 36290536 DOI: 10.3390/bioengineering9100568  0.306
2020 May AG, Orizondo RA, Frankowski BJ, Ye SH, Kocyildirim E, Wagner WR, D'Cunha J, Federspiel WJ. In vivo testing of the low-flow CO removal application of a compact, platform respiratory device. Intensive Care Medicine Experimental. 8: 45. PMID 32804310 DOI: 10.1186/S40635-020-00329-9  0.339
2020 Cove ME, Vu LH, Ring T, Federspiel WJ, Kellum JA. Respiratory Dialysis-A Novel Low Bicarbonate Dialysate to Provide Extracorporeal CO2 Removal. Critical Care Medicine. PMID 32304418 DOI: 10.1097/Ccm.0000000000004351  0.381
2020 May AG, Omecinski KS, Frankowski BJ, Federspiel WJ. Effect of Hematocrit on the CO2 Removal Rate of Artificial Lungs. Asaio Journal (American Society For Artificial Internal Organs : 1992). PMID 32134794 DOI: 10.1097/Mat.0000000000001140  0.396
2019 Madhani SP, May AG, Frankowski BJ, Burgreen GW, Federspiel WJ. Blood Recirculation Enhances Oxygenation Efficiency of Artificial Lungs. Asaio Journal (American Society For Artificial Internal Organs : 1992). PMID 31335366 DOI: 10.1097/Mat.0000000000001030  0.405
2018 May AG, Orizondo RA, Frankowski BJ, Wearden PD, Federspiel WJ. Acute In Vivo Evaluation of the Pittsburgh Pediatric Ambulatory Lung. Asaio Journal (American Society For Artificial Internal Organs : 1992). PMID 30507846 DOI: 10.1097/Mat.0000000000000918  0.359
2018 Cove ME, Vu LH, Ring T, May AG, Federspiel WJ, Kellum JA. A Proof of Concept Study, Demonstrating Extracorporeal Carbon Dioxide Removal Using Hemodialysis with a Low Bicarbonate Dialysate. Asaio Journal (American Society For Artificial Internal Organs : 1992). PMID 30281542 DOI: 10.1097/Mat.0000000000000879  0.343
2018 May AG, Jeffries RG, Frankowski BJ, Burgreen GW, Federspiel WJ. Bench Validation of a Compact Low-Flow CO Removal Device. Intensive Care Medicine Experimental. 6: 34. PMID 30251223 DOI: 10.1186/S40635-018-0200-7  0.356
2018 Orizondo RA, Gino G, Sultzbach G, Madhani SP, Frankowski BJ, Federspiel WJ. Effects of Hollow Fiber Membrane Oscillation on an Artificial Lung. Annals of Biomedical Engineering. PMID 29464460 DOI: 10.1007/S10439-018-1995-9  0.391
2018 Malkin AD, Ye SH, Lee EJ, Yang X, Zhu Y, Gamble LJ, Federspiel WJ, Wagner WR. Development of zwitterionic sulfobetaine block copolymer conjugation strategies for reduced platelet deposition in respiratory assist devices. Journal of Biomedical Materials Research. Part B, Applied Biomaterials. PMID 29424964 DOI: 10.1002/Jbm.B.34085  0.396
2017 Madhani SP, Frankowski BJ, Ye SH, Burgreen GW, Wagner WR, Kormos R, D'Cunha J, Federspiel WJ. In Vivo 5 Day Animal Studies of a Compact, Wearable Pumping Artificial Lung. Asaio Journal (American Society For Artificial Internal Organs : 1992). PMID 29240631 DOI: 10.1097/Mat.0000000000000740  0.367
2017 Orizondo RA, May AG, Madhani SP, Frankowski BJ, Burgreen GW, Wearden PD, Federspiel WJ. In Vitro Characterization of the Pittsburgh Pediatric Ambulatory Lung. Asaio Journal (American Society For Artificial Internal Organs : 1992). PMID 29240630 DOI: 10.1097/Mat.0000000000000711  0.38
2017 Jeffries RG, Lund L, Frankowski B, Federspiel WJ. An extracorporeal carbon dioxide removal (ECCO2R) device operating at hemodialysis blood flow rates. Intensive Care Medicine Experimental. 5: 41. PMID 28875449 DOI: 10.1186/S40635-017-0154-1  0.75
2017 May AG, Sen A, Cove ME, Kellum JA, Federspiel WJ. Extracorporeal CO2 removal by hemodialysis: in vitro model and feasibility. Intensive Care Medicine Experimental. 5: 20. PMID 28390055 DOI: 10.1186/S40635-017-0132-7  0.364
2017 Madhani SP, Frankowski BJ, Burgreen GW, Antaki JF, Kormos R, D'Cunha J, Federspiel WJ. In vitro and in vivo evaluation of a novel integrated wearable artificial lung. The Journal of Heart and Lung Transplantation : the Official Publication of the International Society For Heart Transplantation. PMID 28359655 DOI: 10.1016/J.Healun.2017.02.025  0.309
2017 Madhani SP, Frankowski BJ, Federspiel WJ. Fiber bundle design for an integrated wearable artificial lung. Asaio Journal (American Society For Artificial Internal Organs : 1992). PMID 28187049 DOI: 10.1097/Mat.0000000000000542  0.438
2016 Parker RS, Hogg JS, Roy A, Kellum JA, Rimmelé T, Daun-Gruhn S, Fedorchak MV, Valenti IE, Federspiel WJ, Rubin J, Vodovotz Y, Lagoa C, Clermont G. Modeling and Hemofiltration Treatment of Acute Inflammation. Processes (Basel, Switzerland). 4: 38. PMID 33134139 DOI: 10.3390/pr4040038  0.713
2016 Madhani SP, D'Aloiso BD, Frankowski B, Federspiel WJ. Darcy Permeability of Hollow Fiber Membrane Bundles Made from Membrana Polymethylpentene Fibers Used in Respiratory Assist Devices. Asaio Journal (American Society For Artificial Internal Organs : 1992). 62: 329-31. PMID 26809086 DOI: 10.1097/Mat.0000000000000348  0.399
2015 Arazawa DT, Kimmel JD, Finn MC, Federspiel WJ. Acidic sweep gas with carbonic anhydrase coated hollow fiber membranes synergistically accelerates CO2 removal from blood. Acta Biomaterialia. 25: 143-9. PMID 26159104 DOI: 10.1016/J.Actbio.2015.07.007  0.807
2015 Arazawa DT, Kimmel JD, Federspiel WJ. Kinetics of CO2 exchange with carbonic anhydrase immobilized on fiber membranes in artificial lungs. Journal of Materials Science. Materials in Medicine. 26: 193. PMID 26032115 DOI: 10.1007/S10856-015-5525-0  0.801
2015 Cove ME, Federspiel WJ. Veno-venous extracorporeal CO2 removal for the treatment of severe respiratory acidosis. Critical Care (London, England). 19: 176. PMID 25927222 DOI: 10.1186/S13054-015-0769-0  0.396
2015 Zhang J, Peng Z, Maberry D, Volpe J, Kimmel JD, Federspiel WJ, Kellum JA. Effects of hemoadsorption with a novel adsorbent on sepsis: in vivo and in vitro study. Blood Purification. 39: 239-45. PMID 25833160 DOI: 10.1159/000381006  0.763
2015 Ye SH, Arazawa DT, Zhu Y, Shankarraman V, Malkin AD, Kimmel JD, Gamble LJ, Ishihara K, Federspiel WJ, Wagner WR. Hollow fiber membrane modification with functional zwitterionic macromolecules for improved thromboresistance in artificial lungs. Langmuir : the Acs Journal of Surfaces and Colloids. 31: 2463-71. PMID 25669307 DOI: 10.1021/La504907M  0.812
2015 Artemyev M, Zabetakis P, Ronco C, Germain MJ, Lam M, Oei EL, Armignacco P, Garzotto F, Neri M, Teitelbaum I, Weitzel WF, Diaz-Buxo JA, Fan SL, Unruh M, Parvez S, ... ... Federspiel WJ, et al. Annual Congress of the Chinese Blood Purification Center Administration Committee. September 25-28, 2014, Guangzhou: Abstracts Blood Purification. 39: 230-237. DOI: 10.1159/000380930  0.764
2015 Madhani S, Federspiel WJ. Letter to the Editor on: “Darcy permeability of hollow fiber bundles used in blood oxygenation devices” [J. Membr. Sci. 382 (2011) 238-242] Journal of Membrane Science. 496: 359-360. DOI: 10.1016/J.Memsci.2015.09.012  0.387
2014 Jeffries RG, Mussin Y, Bulanin DS, Lund LW, Kocyildirim E, Zhumadilov ZZh, Olzhayev FS, Federspiel WJ, Wearden PD. Pre-clinical evaluation of an adult extracorporeal carbon dioxide removal system with active mixing for pediatric respiratory support. The International Journal of Artificial Organs. 37: 888-99. PMID 25588763 DOI: 10.5301/Ijao.5000372  0.753
2014 Peng ZY, Bishop JV, Wen XY, Elder MM, Zhou F, Chuasuwan A, Carter MJ, Devlin JE, Kaynar AM, Singbartl K, Pike F, Parker RS, Clermont G, Federspiel WJ, Kellum JA. Modulation of chemokine gradients by apheresis redirects leukocyte trafficking to different compartments during sepsis, studies in a rat model. Critical Care (London, England). 18: R141. PMID 24992991 DOI: 10.1186/Cc13969  0.316
2014 Jeffries RG, Frankowski BJ, Burgreen GW, Federspiel WJ. Effect of impeller design and spacing on gas exchange in a percutaneous respiratory assist catheter. Artificial Organs. 38: 1007-17. PMID 24749994 DOI: 10.1111/Aor.12308  0.406
2013 Lund LW, Federspiel WJ. Removing extra CO2 in COPD patients. Current Respiratory Care Reports. 2: 131-138. PMID 23926463 DOI: 10.1007/s13665-013-0057-x  0.718
2013 Kimmel JD, Arazawa DT, Ye SH, Shankarraman V, Wagner WR, Federspiel WJ. Carbonic anhydrase immobilized on hollow fiber membranes using glutaraldehyde activated chitosan for artificial lung applications. Journal of Materials Science. Materials in Medicine. 24: 2611-21. PMID 23888352 DOI: 10.1007/S10856-013-5006-2  0.812
2013 Rimmelé T, Kaynar AM, McLaughlin JN, Bishop JV, Fedorchak MV, Chuasuwan A, Peng Z, Singbartl K, Frederick DR, Zhu L, Carter M, Federspiel WJ, Zeevi A, Kellum JA. Leukocyte capture and modulation of cell-mediated immunity during human sepsis: an ex vivo study. Critical Care (London, England). 17: R59. PMID 23531333 DOI: 10.1186/Cc12587  0.733
2013 Sen A, Kellum J, Federspiel W. 209 Critical Care Medicine. 41: A47. DOI: 10.1097/01.Ccm.0000439357.52072.A2  0.307
2012 Cove ME, MacLaren G, Federspiel WJ, Kellum JA. Bench to bedside review: Extracorporeal carbon dioxide removal, past present and future. Critical Care (London, England). 16: 232. PMID 23014710 DOI: 10.1186/Cc11356  0.317
2012 Alikhani A, Federspiel WJ. Selective capture of anti-A antibodies from human blood using a novel integrated bead and hollow fiber module. Journal of Biomedical Materials Research. Part B, Applied Biomaterials. 100: 2114-21. PMID 22987735 DOI: 10.1002/Jbm.B.32776  0.799
2012 Arazawa DT, Oh HI, Ye SH, Johnson CA, Woolley JR, Wagner WR, Federspiel WJ. Immobilized Carbonic Anhydrase on Hollow Fiber Membranes Accelerates CO(2) Removal from Blood. Journal of Membrane Science. 404: 25-31. PMID 22962517 DOI: 10.1016/J.Memsci.2012.02.006  0.413
2012 Wearden PD, Federspiel WJ, Morley SW, Rosenberg M, Bieniek PD, Lund LW, Ochs BD. Respiratory dialysis with an active-mixing extracorporeal carbon dioxide removal system in a chronic sheep study. Intensive Care Medicine. 38: 1705-11. PMID 22926651 DOI: 10.1007/S00134-012-2651-8  0.745
2012 Namas RA, Namas R, Lagoa C, Barclay D, Mi Q, Zamora R, Peng Z, Wen X, Fedorchak MV, Valenti IE, Federspiel WJ, Kellum JA, Vodovotz Y. Hemoadsorption reprograms inflammation in experimental gram-negative septic peritonitis: insights from in vivo and in silico studies. Molecular Medicine (Cambridge, Mass.). 18: 1366-74. PMID 22751621 DOI: 10.2119/Molmed.2012.00106  0.704
2012 Peng ZY, Wang HZ, Carter MJ, Dileo MV, Bishop JV, Zhou FH, Wen XY, Rimmelé T, Singbartl K, Federspiel WJ, Clermont G, Kellum JA. Acute removal of common sepsis mediators does not explain the effects of extracorporeal blood purification in experimental sepsis. Kidney International. 81: 363-9. PMID 21918497 DOI: 10.1038/Ki.2011.320  0.325
2011 Pacella HE, Eash HJ, Federspiel WJ. Darcy Permeability of Hollow Fiber Bundles Used in Blood Oxygenation Devices. Journal of Membrane Science. 382: 238-242. PMID 22927706 DOI: 10.1016/J.Memsci.2011.08.012  0.392
2011 Kimmel JD, Harbert EM, Parker RS, Federspiel WJ. Modeling competitive cytokine adsorption dynamics within hemoadsorption beads used to treat sepsis. Journal of Chromatography. A. 1218: 8013-20. PMID 21962329 DOI: 10.1016/J.Chroma.2011.09.007  0.774
2011 Kimmel JD, Lacko CS, Delude RL, Federspiel WJ. Characterizing accelerated capture of deoligomerized TNF within hemoadsorption beads used to treat sepsis. Journal of Biomedical Materials Research. Part B, Applied Biomaterials. 98: 47-53. PMID 21504054 DOI: 10.1002/Jbm.B.31830  0.777
2011 Batchinsky AI, Jordan BS, Regn D, Necsoiu C, Federspiel WJ, Morris MJ, Cancio LC. Respiratory dialysis: reduction in dependence on mechanical ventilation by venovenous extracorporeal CO2 removal. Critical Care Medicine. 39: 1382-7. PMID 21317644 DOI: 10.1097/Ccm.0B013E31820Eda45  0.333
2011 Alikhani A, Federspiel WJ. Theoretical and experimental analysis of anti-A antibody capture in novel integrated bead and hollow fiber modules. Annals of Biomedical Engineering. 39: 953-63. PMID 21161682 DOI: 10.1007/S10439-010-0233-X  0.805
2011 DiLeo MV, Fisher JD, Burton BM, Federspiel WJ. Selective improvement of tumor necrosis factor capture in a cytokine hemoadsorption device using immobilized anti-tumor necrosis factor. Journal of Biomedical Materials Research. Part B, Applied Biomaterials. 96: 127-33. PMID 21086427 DOI: 10.1002/Jbm.B.31748  0.342
2010 Gautam S, Korchagina EY, Bovin NV, Federspiel WJ. Specific antibody filter (SAF) binding capacity enhancement to remove anti-A antibodies. Journal of Biomedical Materials Research. Part B, Applied Biomaterials. 95: 475-80. PMID 20878917 DOI: 10.1002/Jbm.B.31707  0.411
2010 Oh HI, Ye SH, Johnson CA, Woolley JR, Federspiel WJ, Wagner WR. Hemocompatibility assessment of carbonic anhydrase modified hollow fiber membranes for artificial lungs. Artificial Organs. 34: 439-42. PMID 20633159 DOI: 10.1111/J.1525-1594.2009.00882.X  0.413
2010 Polk AA, Maul TM, McKeel DT, Snyder TA, Lehocky CA, Pitt B, Stolz DB, Federspiel WJ, Wagner WR. A biohybrid artificial lung prototype with active mixing of endothelialized microporous hollow fibers. Biotechnology and Bioengineering. 106: 490-500. PMID 20091735 DOI: 10.1002/Bit.22675  0.421
2010 Kimmel JD, Gibson GA, Watkins SC, Kellum JA, Federspiel WJ. IL-6 adsorption dynamics in hemoadsorption beads studied using confocal laser scanning microscopy. Journal of Biomedical Materials Research. Part B, Applied Biomaterials. 92: 390-6. PMID 19904819 DOI: 10.1002/Jbm.B.31527  0.768
2009 Mihelc KM, Frankowski BJ, Lieber SC, Moore ND, Hattler BG, Federspiel WJ. Evaluation of a respiratory assist catheter that uses an impeller within a hollow fiber membrane bundle. Asaio Journal (American Society For Artificial Internal Organs : 1992). 55: 569-74. PMID 19779302 DOI: 10.1097/Mat.0B013E3181Bc2655  0.416
2009 DiLeo MV, Fisher JD, Federspiel WJ. Experimental validation of a theoretical model of cytokine capture using a hemoadsorption device. Annals of Biomedical Engineering. 37: 2310-6. PMID 19680812 DOI: 10.1007/S10439-009-9780-4  0.328
2009 Alikhani A, Korchagina EY, Chinarev AA, Bovin NV, Federspiel WJ. High molecular weight blood group A trisaccharide-polyacrylamide glycoconjugates as synthetic blood group A antigens for anti-A antibody removal devices. Journal of Biomedical Materials Research. Part B, Applied Biomaterials. 91: 845-54. PMID 19582848 DOI: 10.1002/Jbm.B.31466  0.781
2009 Budilarto SG, Frankowski BJ, Hattler BG, Federspiel WJ. Flow visualization study of a novel respiratory assist catheter. Artificial Organs. 33: 411-8. PMID 19473135 DOI: 10.1111/J.1525-1594.2009.00751.X  0.37
2009 Burgess KA, Hu HH, Wagner WR, Federspiel WJ. Towards microfabricated biohybrid artificial lung modules for chronic respiratory support. Biomedical Microdevices. 11: 117-27. PMID 18696229 DOI: 10.1007/S10544-008-9215-2  0.338
2009 Batchinsky AI, Jordan BS, Regn D, Necsoiu C, Morley S, Rosenberg M, Federspiel W, Hattler B, Morris M, Blackbourne L, Cancio LC. VENO-VENOUS EXTRACORPOREAL CO2 REMOVAL: REDUCTION IN DEPENDENCE ON MECHANICAL VENTILATION VIA THE HEMOLUNG ARTIFICIAL LUNG SYSTEM Chest. 136: 61S. DOI: 10.1378/Chest.136.4_Meetingabstracts.61S-G  0.324
2008 Svitek RG, Federspiel WJ. A mathematical model to predict CO2 removal in hollow fiber membrane oxygenators. Annals of Biomedical Engineering. 36: 992-1003. PMID 18347984 DOI: 10.1007/S10439-008-9482-3  0.788
2008 Gautam S, Korchagina EY, Bovin NV, Federspiel WJ. Monoclonal anti-A antibody removal by synthetic A antigen immobilized on specific antibody filters. Biotechnology and Bioengineering. 99: 876-83. PMID 17705231 DOI: 10.1002/Bit.21621  0.411
2007 Zinovik IN, Federspiel WJ. Modeling of blood flow in a balloon-pulsed intravascular respiratory catheter. Asaio Journal (American Society For Artificial Internal Organs : 1992). 53: 464-8. PMID 17667232 DOI: 10.1097/Mat.0B013E31805Fe96D  0.375
2007 Eash HJ, Mihelc KM, Frankowski BJ, Hattler BG, Federspiel WJ. Evaluation of fiber bundle rotation for enhancing gas exchange in a respiratory assist catheter. Asaio Journal (American Society For Artificial Internal Organs : 1992). 53: 368-73. PMID 17515731 DOI: 10.1097/Mat.0B013E318031Af3B  0.45
2007 Kaar JL, Oh HI, Russell AJ, Federspiel WJ. Towards improved artificial lungs through biocatalysis. Biomaterials. 28: 3131-9. PMID 17433433 DOI: 10.1016/J.Biomaterials.2007.03.021  0.384
2006 Solovan JC, Oh HI, Alikhani A, Gautam S, Vlasova K, Korchagina EY, Bovin NV, Federspiel WJ. Synthetic blood group antigens for anti-A removal device and their interaction with monoclonal anti-A IgM. Transplant Immunology. 16: 245-9. PMID 17138061 DOI: 10.1016/J.Trim.2006.08.003  0.783
2006 Snyder TA, Eash HJ, Litwak KN, Frankowski BJ, Hattler BG, Federspiel WJ, Wagner WR. Blood biocompatibility assessment of an intravenous gas exchange device. Artificial Organs. 30: 657-64. PMID 16934093 DOI: 10.1111/J.1525-1594.2006.00281.X  0.379
2006 Eash HJ, Budilarto SG, Hattler BG, Federspiel WJ. Investigating the effects of random balloon pulsation on gas exchange in a respiratory assist catheter. Asaio Journal (American Society For Artificial Internal Organs : 1992). 52: 192-5. PMID 16557107 DOI: 10.1097/01.Mat.0000199752.89066.83  0.384
2006 Oh H, Kaar JL, Russell AJ, Federspiel WJ. IMMOBILIZATION AND ASSESSMENT OF CARBONIC ANHYDRASE ON HOLLOW FIBER MEMBRANES FOR ENZYME-ENHANCED ARTIFICIAL LUNGS Asaio Journal. 52: 67A. DOI: 10.1097/00002480-200603000-00282  0.366
2006 Polk AA, McKeel DT, Federspiel WJ, Wagner WR. A BIOHYBRID LUNG PROTOTYPE WITH ACTIVE MIXING AND OXYGENATION OF ENDOTHELIALIZED MICROPOROUS HOLLOW FIBERS Asaio Journal. 52: 67A. DOI: 10.1097/00002480-200603000-00281  0.364
2006 Gautam S, Alikhani AH, Bovin NV, Federspiel WJ. ANTIBODY REMOVAL BY IMMOBILIZED SYNTHETIC ANTIGEN IN SPECIFIC ANTIBODY FILTERS Asaio Journal. 52: 13A. DOI: 10.1097/00002480-200603000-00068  0.766
2005 Svitek RG, Frankowski BJ, Federspiel WJ. Evaluation of a pumping assist lung that uses a rotating fiber bundle. Asaio Journal (American Society For Artificial Internal Organs : 1992). 51: 773-80. PMID 16340367 DOI: 10.1097/01.Mat.0000178970.00971.43  0.813
2005 Budilarto SG, Frankowski BJ, Hattler BG, Federspiel WJ. Flow visualization study of a pulsating respiratory assist catheter. Asaio Journal (American Society For Artificial Internal Organs : 1992). 51: 673-80. PMID 16340349 DOI: 10.1097/01.Mat.0000187393.79866.9C  0.408
2005 Eash HJ, Frankowski BJ, Hattler BG, Federspiel WJ. Evaluation of local gas exchange in a pulsating respiratory support catheter. Asaio Journal (American Society For Artificial Internal Organs : 1992). 51: 152-7. PMID 15839440 DOI: 10.1097/01.Mat.0000153648.11692.D0  0.436
2005 Kanick SC, Doyle WJ, Ghadiali SN, Federspiel WJ. On morphometric measurement of oxygen diffusing capacity in middle ear gas exchange. Journal of Applied Physiology (Bethesda, Md. : 1985). 98: 114-9. PMID 15310742 DOI: 10.1152/Japplphysiol.00203.2004  0.32
2005 Polk AA, McKeel DT, Federspiel WJ, Wagner WR. A BIOHYBRID LUNG PROTOTYPE WITH ENDOTHELIALIZED MICROPOROUS HOLLOW FIBERS IN A ROTATING MODULE Asaio Journal. 51: 55A. DOI: 10.1097/00002480-200503000-00217  0.336
2005 Hagglund NJ, Frankowski BJ, Hattler BG, Federspiel WJ. THE POTENTIAL USE OF ROTATIONAL FIBER BUNDLES IN RESPIRATORY ASSIST CATHETERS Asaio Journal. 51: 53A. DOI: 10.1097/00002480-200503000-00209  0.346
2005 Svitek RG, Frankowski BJ, Federspiel WJ. THE EFFECT OF BUNDLE POROSITY ON THE PERFORMANCE OF A PUMPING PARACORPOREAL ASSIST LUNG USING A ROTATING FIBER BUNDLE Asaio Journal. 51: 52A. DOI: 10.1097/00002480-200503000-00207  0.778
2005 Eash HJ, Budilarto SG, Hattler BG, Federspiel WJ. CAN RANDOM BALLON PULSATION ENHANCE GAS EXCHANGE IN A PULSATING RESPIRATORY SUPPORT CATHETER? Asaio Journal. 51: 49A. DOI: 10.1097/00002480-200503000-00194  0.315
2004 Eash HJ, Jones HM, Hattler BG, Federspiel WJ. Evaluation of plasma resistant hollow fiber membranes for artificial lungs. Asaio Journal (American Society For Artificial Internal Organs : 1992). 50: 491-7. PMID 15497391 DOI: 10.1097/01.Mat.0000138078.04558.Fe  0.388
2004 Nolan TD, Hattler BG, Federspiel WJ. Development of a balloon volume sensor for pulsating balloon catheters. Asaio Journal (American Society For Artificial Internal Organs : 1992). 50: 225-33. PMID 15171473 DOI: 10.1097/01.Mat.0000123635.20778.52  0.325
2004 Zinovik IN, Svitek RG, Federspiel WJ. CFD ANALYSIS OF HYDRODYNAMIC CHARACTERISTICS OF A NOVEL PARACORPOREALPUMPING ARTIFICIAL LUNG Asaio Journal. 50: 157. DOI: 10.1097/00002480-200403000-00186  0.751
2004 Eash HJ, Frankowski BJ, Hattler BG, Federspiel WJ. EVALUATION OF LOCAL GAS EXCHANGE IN AN ARTIFICIAL LUNG CATHETER Asaio Journal. 50: 153. DOI: 10.1097/00002480-200403000-00168  0.317
2003 Hout MS, Federspiel WJ. Mathematical and experimental analyses of antibody transport in hollow-fiber-based specific antibody filters. Biotechnology Progress. 19: 1553-61. PMID 14524719 DOI: 10.1021/Bp025796F  0.787
2003 Eash HJ, Frankowski BJ, Litwak K, Wagner WR, Hattler BG, Federspiel WJ. Acute in vivo testing of a respiratory assist catheter: implants in calves versus sheep. Asaio Journal (American Society For Artificial Internal Organs : 1992). 49: 370-7. PMID 12918576 DOI: 10.1097/01.Mat.0000074991.94234.B6  0.326
2003 Polk AA, Federspiel WJ, Wagner WR. MODIFICATION OF MICROPOROUS HOLLOW FIBERS TO SUPPORT ENDOTHELIAL CELL ADHESION Asaio Journal. 49: 217. DOI: 10.1097/00002480-200303000-00303  0.315
2002 Lund LW, Hattler BG, Federspiel WJ. A comparative in vitro hemolysis study of a pulsating intravenous artificial lung. Asaio Journal (American Society For Artificial Internal Organs : 1992). 48: 631-5. PMID 12455773 DOI: 10.1097/00002480-200211000-00009  0.768
2002 Hattler BG, Lund LW, Golob J, Russian H, Lann MF, Merrill TL, Frankowski B, Federspiel WJ. A respiratory gas exchange catheter: in vitro and in vivo tests in large animals. The Journal of Thoracic and Cardiovascular Surgery. 124: 520-30. PMID 12202869 DOI: 10.1067/Mtc.2002.123811  0.751
2002 Garcia MY, Hattler BG, Federspiel WJ. Effect of vessel compliance on the in-vitro performance of a pulsating respiratory support catheter. Journal of Biomechanical Engineering. 124: 56-62. PMID 11871606 DOI: 10.1115/1.1428556  0.388
2002 Golob JF, Federspiel WJ, Merrill TL, Frankowski BJ, Litwak K, Russian H, Hattler BG. Acute in vivo testing of an intravascular respiratory support catheter. Asaio Journal (American Society For Artificial Internal Organs : 1992). 47: 432-7. PMID 11575808 DOI: 10.1097/00002480-200109000-00003  0.445
2002 Hout MS, Federspiel WJ. KINETICS OF EXTRACORPOREAL ANTIBODY REMOVAL BY HOLLOW FIBER-BASED SELECTIVE ANTIBODY FILTERS Asaio Journal. 48: 196. DOI: 10.1097/00002480-200203000-00281  0.789
2002 Russian HJ, Conover SP, Hattler BC, Federspiel WJ. EVALUATION OF PLASMA RESISTANT COATINGS FOR HOLLOW FIBER MEMBRANES Asaio Journal. 48: 155. DOI: 10.1097/00002480-200203000-00121  0.309
2002 Lund LW, Hattler BG, Federspiel WJ. Gas permeance measurement of hollow fiber membranes in gas-liquid environment Aiche Journal. 48: 635-643. DOI: 10.1002/Aic.690480320  0.744
2000 Hout MS, LeJeune KE, Schaack TM, Bristow DK, Federspiel WJ. Specific removal of anti-A and anti-B antibodies by using modified dialysis filters. Asaio Journal (American Society For Artificial Internal Organs : 1992). 46: 702-6. PMID 11110267 DOI: 10.1097/00002480-200011000-00010  0.784
2000 Federspiel WJ, Golob JF, Merrill TL, Lund LW, Bultman JA, Frankowski BJ, Watach M, Litwak K, Hattler BG. Ex vivo testing of the intravenous membrane oxygenator. Asaio Journal (American Society For Artificial Internal Organs : 1992). 46: 261-7. PMID 10826733 DOI: 10.1097/00002480-200005000-00004  0.777
2000 Hout MS, Hattler BG, Federspiel WJ. Validation of a model for flow-dependent carbon dioxide exchange in artificial lungs. Artificial Organs. 24: 114-8. PMID 10718764 DOI: 10.1046/J.1525-1594.2000.06465.X  0.787
2000 Federspiel WJ, Hewitt TJ, Hattler BG. Experimental evaluation of a model for oxygen exchange in a pulsating intravascular artificial lung. Annals of Biomedical Engineering. 28: 160-167. PMID 10710187 DOI: 10.1114/1.240  0.413
2000 Merrill TL, Hattler BG, Federspiel WJ. DETERMINING OXYGEN EXCHANGE FROM GAS-SIDE ANALYSIS IN ARTIFICIAL LUNGS Asaio Journal. 46: 180. DOI: 10.1097/00002480-200003000-00118  0.336
1999 Hout MS, LeJeune KE, Schaack T, Bristow D, Federspiel WJ. SPECIFIC REMOVAL OF ANTI-A AND ANTI-B ANTIBODIES USING MODIFIED DIALYSIS AND PLASMAPHERESIS FILTERS Asaio Journal. 45: 193. DOI: 10.1097/00002480-199903000-00290  0.769
1998 Hewitt TJ, Hattler BG, Federspiel WJ. A mathematical model of gas exchange in an intravenous membrane oxygenator. Annals of Biomedical Engineering. 26: 166-178. PMID 10355561 DOI: 10.1114/1.53  0.427
1998 Lund LW, Hattler BG, Federspiel WJ. Is condensation the cause of plasma leakage in microporous hollow fiber membrane oxygenators Journal of Membrane Science. 147: 87-93. DOI: 10.1016/S0376-7388(98)00121-5  0.772
1997 Federspiel WJ, Hout MS, Hewitt TJ, Lund LW, Heinrich SA, Litwak P, Walters FR, Reeder GD, Borovetz HS, Hattler BG. Development of a low flow resistance intravenous oxygenator. Asaio Journal (American Society For Artificial Internal Organs : 1992). 43: M725-30. PMID 9360141 DOI: 10.1097/00002480-199703000-00047  0.803
1997 Kameneva MV, Borovetz HS, Antaki JF, Litwak P, Federspiel WJ, Kormos RL, Griffith BP. Effect of perfluorochemical emulsion on hemorheology and shear induced blood trauma: Possible mechanisms and future applications Advances in Experimental Medicine and Biology. 411: 383-390. PMID 9269453 DOI: 10.1007/978-1-4615-5865-1_49  0.327
1997 Konishi R, Shimizu R, Firestone L, Walters FR, Wagner WR, Federspiel WJ, Konishi H, Hattler BG. Nitric oxide prevents human platelet adhesion to fiber membranes in whole blood. Asaio Journal (American Society For Artificial Internal Organs : 1992). 42: M850-3. PMID 8945004 DOI: 10.1097/00002480-199609000-00111  0.399
1996 Federspiel WJ, Hewitt T, Hout MS, Walters FR, Lund LW, Sawzik PJ, Reeder G, Borovetz HS, Hattler BG. Recent progress in engineering the Pittsburgh intravenous membrane oxygenator. Asaio Journal (American Society For Artificial Internal Organs : 1992). 42: M435-42. PMID 9063960 DOI: 10.1097/00002480-199609000-00026  0.8
1996 Macha M, Federspiel WJ, Lund LW, Sawzik PJ, Litwak P, Walters FR, Reeder GD, Borovetz HS, Hattler BG. Acute in vivo studies of the Pittsburgh intravenous membrane oxygenator. Asaio Journal (American Society For Artificial Internal Organs : 1992). 42: M609-15. PMID 8944953 DOI: 10.1097/00002480-199609000-00060  0.77
1996 Lund LW, Federspiel WJ, Walters FR, Hattler BG. A novel method for measuring hollow fiber membrane permeability in a gas-liquid system. Asaio Journal (American Society For Artificial Internal Organs : 1992). 42: M446-51. PMID 8944921 DOI: 10.1097/00002480-199609000-00028  0.766
1996 Federspiel WJ, Hattler BG. Sweep gas flowrate and CO2 exchange in artificial lungs. Artificial Organs. 20: 1050-2. PMID 8864027 DOI: 10.1111/J.1525-1594.1996.Tb04593.X  0.382
1996 Lund LW, Federspiel WJ, Hattler BG. Gas permeability of hollow fiber membranes in a gas-liquid system Journal of Membrane Science. 117: 207-219. DOI: 10.1016/0376-7388(96)00064-6  0.765
1996 Federspiel WJ, Williams JL, Hattler BG. Gas flow dynamics in hollow-fiber membranes Aiche Journal. 42: 2094-2099. DOI: 10.1002/Aic.690420732  0.387
1985 Clark A, Federspiel WJ, Clark PAA, Cokelet GR. Oxygen delivery from red cells Biophysical Journal. 47: 171-181. PMID 3978198 DOI: 10.1016/S0006-3495(85)83890-X  0.711