Carsten H. Wolters, Ph.D. - Publications

Affiliations: 
University Hospital Muenster Institute for Biomagnetism 

85 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2023 Delatolas T, Antonakakis M, Wolters CH, Zervakis M. EEG Source Analysis with a Convolutional Neural Network and Finite Element Analysis. Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual International Conference. 2023: 1-4. PMID 38083731 DOI: 10.1109/EMBC40787.2023.10340742  0.323
2023 Erdbrügger T, Westhoff A, Höltershinken M, Radecke JO, Buschermöhle Y, Buyx A, Wallois F, Pursiainen S, Gross J, Lencer R, Engwer C, Wolters C. CutFEM forward modeling for EEG source analysis. Frontiers in Human Neuroscience. 17: 1216758. PMID 37694172 DOI: 10.3389/fnhum.2023.1216758  0.377
2023 Radecke JO, Fiene M, Misselhorn J, Herrmann CS, Engel AK, Wolters CH, Schneider TR. Personalized alpha-tACS targeting left posterior parietal cortex modulates visuo-spatial attention and posterior evoked EEG activity. Brain Stimulation. 16: 1047-1061. PMID 37353071 DOI: 10.1016/j.brs.2023.06.013  0.529
2023 Unnwongse K, Rampp S, Wehner T, Kowoll A, Parpaley Y, von Lehe M, Lanfer B, Rusiniak M, Wolters C, Wellmer J. Validating EEG source imaging using intracranial electrical stimulation. Brain Communications. 5: fcad023. PMID 36824389 DOI: 10.1093/braincomms/fcad023  0.341
2023 Medani T, Garcia-Prieto J, Tadel F, Antonakakis M, Erdbrügger T, Höltershinken M, Mead W, Schrader S, Joshi A, Engwer C, Wolters CH, Mosher JC, Leahy RM. Brainstorm-DUNEuro: An integrated and user-friendly Finite Element Method for modeling electromagnetic brain activity. Neuroimage. 119851. PMID 36599389 DOI: 10.1016/j.neuroimage.2022.119851  0.326
2022 Neugebauer F, Antonakakis M, Unnwongse K, Parpaley Y, Wellmer J, Rampp S, Wolters CH. Validating EEG, MEG and Combined MEG and EEG Beamforming for an Estimation of the Epileptogenic Zone in Focal Cortical Dysplasia. Brain Sciences. 12. PMID 35053857 DOI: 10.3390/brainsci12010114  0.3
2021 Khan A, Antonakakis M, Vogenauer N, Haueisen J, Wolters CH. Individually optimized multi-channel tDCS for targeting somatosensory cortex. Clinical Neurophysiology : Official Journal of the International Federation of Clinical Neurophysiology. 134: 9-26. PMID 34923283 DOI: 10.1016/j.clinph.2021.10.016  0.305
2021 Rezaei A, Lahtinen J, Neugebauer F, Antonakakis M, Piastra MC, Koulouri A, Wolters CH, Pursiainen S. Reconstructing subcortical and cortical somatosensory activity via the RAMUS inverse source analysis technique using median nerve SEP data. Neuroimage. 245: 118726. PMID 34838947 DOI: 10.1016/j.neuroimage.2021.118726  0.315
2020 Khan A, Antonakakis M, Schneider TR, Wolters CH. P120 Combined EEG/MEG targeting and multi-electrode individually optimized tDCS stimulation of the human somatosensory network Clinical Neurophysiology. 131. DOI: 10.1016/J.Clinph.2019.12.231  0.347
2020 Dimakopoulos V, Antonakakis M, Wolters C, Zervakis M. P69 Combined EEG & MEG Source Analysis coupled with a Two - Phase Spike Clustering Approach: A multifocal epilepsy case Clinical Neurophysiology. 131: e212-e213. DOI: 10.1016/J.Clinph.2019.12.070  0.309
2019 Khan A, Haueisen J, Wolters CH, Antonakakis M, Vogenauer N, Wollbrink A, Suntrup-Krueger S, Schneider TR, Herrmann CS, Nitsche M, Paulus W. Constrained maximum intensity optimized multi-electrode tDCS targeting of human somatosensory network. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2019: 5894-5897. PMID 31947191 DOI: 10.1109/EMBC.2019.8857253  0.626
2019 Vorwerk J, Hanrath A, Wolters CH, Grasedyck L. The multipole approach for EEG forward modeling using the finite element method. Neuroimage. 116039. PMID 31369809 DOI: 10.1016/J.Neuroimage.2019.116039  0.415
2019 Vorwerk J, Aydin Ü, Wolters CH, Butson CR. Influence of Head Tissue Conductivity Uncertainties on EEG Dipole Reconstruction. Frontiers in Neuroscience. 13: 531. PMID 31231178 DOI: 10.3389/Fnins.2019.00531  0.425
2019 Pant A, Cho J, Wolters C, Jiang X, Bornfleth H. Comparing different head MRI segmentation techniques for use in EEG source analysis F1000research. 8. DOI: 10.7490/F1000Research.1116378.1  0.333
2019 Zulkifly MFM, Focke NK, Wolters CH, Paulus W. P12-F Blinding of MRI based-individualized electrode montages for modulating excitability of the somatosensory cortex by tACS Clinical Neurophysiology. 130. DOI: 10.1016/J.Clinph.2019.04.465  0.385
2018 Rimpiläinen V, Koulouri A, Lucka F, Kaipio JP, Wolters CH. Improved EEG source localization with Bayesian uncertainty modelling of unknown skull conductivity. Neuroimage. 188: 252-260. PMID 30529398 DOI: 10.1016/J.Neuroimage.2018.11.058  0.396
2018 Iordanov T, Bornfleth H, Wolters CH, Pasheva V, Venkov G, Lanfer B, Scherg M, Scherg T. LORETA With Cortical Constraint: Choosing an Adequate Surface Laplacian Operator. Frontiers in Neuroscience. 12: 746. PMID 30425613 DOI: 10.3389/Fnins.2018.00746  0.325
2018 Miinalainen T, Rezaei A, Us D, Nüßing A, Engwer C, Wolters CH, Pursiainen S. A realistic, accurate and fast source modeling approach for the EEG forward problem. Neuroimage. 184: 56-67. PMID 30165251 DOI: 10.1016/J.Neuroimage.2018.08.054  0.481
2018 Vorwerk J, Oostenveld R, Piastra MC, Magyari L, Wolters CH. The FieldTrip-SimBio pipeline for EEG forward solutions. Biomedical Engineering Online. 17: 37. PMID 29580236 DOI: 10.1186/S12938-018-0463-Y  0.43
2018 Piastra MC, Nüßing A, Vorwerk J, Bornfleth H, Oostenveld R, Engwer C, Wolters CH. The Discontinuous Galerkin Finite Element Method for Solving the MEG and the Combined MEG/EEG Forward Problem. Frontiers in Neuroscience. 12: 30. PMID 29456487 DOI: 10.3389/Fnins.2018.00030  0.476
2017 Neugebauer F, Möddel G, Rampp S, Burger M, Wolters CH. The Effect of Head Model Simplification on Beamformer Source Localization. Frontiers in Neuroscience. 11: 625. PMID 29209157 DOI: 10.3389/Fnins.2017.00625  0.422
2017 Baltus A, Wagner S, Wolters CH, Herrmann CS. Optimized auditory transcranial alternating current stimulation improves individual auditory temporal resolution. Brain Stimulation. PMID 29079460 DOI: 10.1016/J.Brs.2017.10.008  0.574
2017 Pursiainen S, Agsten B, Wagner S, Wolters CH. Advanced boundary electrode modeling for tES and parallel tES/EEG. Ieee Transactions On Neural Systems and Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. PMID 28961118 DOI: 10.1109/Tnsre.2017.2748930  0.433
2017 Aydin Ü, Rampp S, Wollbrink A, Kugel H, Cho J-, Knösche TR, Grova C, Wellmer J, Wolters CH. Zoomed MRI Guided by Combined EEG/MEG Source Analysis: A Multimodal Approach for Optimizing Presurgical Epilepsy Work-up and its Application in a Multi-focal Epilepsy Patient Case Study. Brain Topography. PMID 28510905 DOI: 10.1007/S10548-017-0568-9  0.403
2017 Engwer C, Vorwerk J, Ludewig J, Wolters CH. A Discontinuous Galerkin Method to Solve the EEG Forward Problem Using the Subtraction Approach Siam Journal On Scientific Computing. 39: B138-B164. DOI: 10.1137/15M1048392  0.468
2017 Wolters C. T032 New methods for electrode optimization in high-definition transcranial current stimulation Clinical Neurophysiology. 128: e10-e11. DOI: 10.1016/J.Clinph.2016.10.130  0.457
2016 Pursiainen S, Lew S, Wolters CH. Forward and Inverse Effects of the Complete Electrode Model in Neonatal EEG. Journal of Neurophysiology. jn.00427.2016. PMID 27852731 DOI: 10.1152/Jn.00427.2016  0.411
2016 Pursiainen S, Vorwerk J, Wolters CH. Electroencephalography (EEG) forward modeling via H(div) finite element sources with focal interpolation. Physics in Medicine and Biology. 61: 8502-8520. PMID 27845929 DOI: 10.1088/0031-9155/61/24/8502  0.443
2016 Vorwerk J, Engwer C, Pursiainen S, Wolters CH. A Mixed Finite Element Method to Solve the EEG Forward Problem. Ieee Transactions On Medical Imaging. PMID 27831869 DOI: 10.1109/Tmi.2016.2624634  0.414
2016 Fiederer L, Lahr J, Vorwerk J, Lucka F, Wolters C, Aertsen A, Schulze-Bonhage A, Ball T. Electrical Stimulation of the Human Cerebral Cortex by Extracranial Muscle Activity:Effect Quantification with Intracranial EEG and FEM Simulations. Ieee Transactions On Bio-Medical Engineering. PMID 27448334 DOI: 10.1109/Tbme.2016.2570743  0.326
2016 Nuessing A, Wolters CH, Brinck H, Engwer C. The Unfitted Discontinuous Galerkin Method for Solving the EEG Forward Problem. Ieee Transactions On Bio-Medical Engineering. PMID 27416584 DOI: 10.1109/Tbme.2016.2590740  0.339
2016 Wagner S, Lucka F, Vorwerk J, Herrmann CS, Nolte G, Burger M, Wolters CH. Using reciprocity for relating the simulation of transcranial current stimulation to the EEG forward problem. Neuroimage. PMID 27125841 DOI: 10.1016/J.Neuroimage.2016.04.005  0.664
2016 Lau S, Güllmar D, Flemming L, Grayden DB, Cook MJ, Wolters CH, Haueisen J. Skull Defects in Finite Element Head Models for Source Reconstruction from Magnetoencephalography Signals. Frontiers in Neuroscience. 10: 141. PMID 27092044 DOI: 10.3389/Fnins.2016.00141  0.377
2016 Theiß M, Wollbrink A, Wolters CH, Brinck H. Impact of different registration methods in MEG source analysis Current Directions in Biomedical Engineering. 2: 463-466. DOI: 10.1515/Cdbme-2016-0102  0.312
2016 Wagner S, Burger M, Wolters CH. An Optimization Approach for Well-Targeted Transcranial Direct Current Stimulation Siam Journal On Applied Mathematics. 76: 2154-2174. DOI: 10.1137/15M1026481  0.408
2015 Fiederer LD, Vorwerk J, Lucka F, Dannhauer M, Yang S, Dümpelmann M, Schulze-Bonhage A, Aertsen A, Speck O, Wolters CH, Ball T. The role of blood vessels in high-resolution volume conductor head modeling of EEG. Neuroimage. PMID 26747748 DOI: 10.1016/J.Neuroimage.2015.12.041  0.41
2015 Schmidt C, Wagner S, Burger M, Rienen Uv, Wolters CH. Impact of uncertain head tissue conductivity in the optimization of transcranial direct current stimulation for an auditory target. Journal of Neural Engineering. 12: 046028. PMID 26170066 DOI: 10.1088/1741-2560/12/4/046028  0.397
2015 Bauer M, Pursiainen S, Vorwerk J, Kostler H, Wolters C. Comparison Study for Whitney (Raviart-Thomas) Type Source Models in Finite Element Method Based EEG Forward Modeling. Ieee Transactions On Bio-Medical Engineering. PMID 26054057 DOI: 10.1109/Tbme.2015.2439282  0.475
2015 Aydin Ü, Vorwerk J, Dümpelmann M, Küpper P, Kugel H, Heers M, Wellmer J, Kellinghaus C, Haueisen J, Rampp S, Stefan H, Wolters CH. Combined EEG/MEG can outperform single modality EEG or MEG source reconstruction in presurgical epilepsy diagnosis. Plos One. 10: e0118753. PMID 25761059 DOI: 10.1371/Journal.Pone.0118753  0.339
2015 Cho JH, Vorwerk J, Wolters CH, Knösche TR. Influence of the head model on EEG and MEG source connectivity analyses. Neuroimage. 110: 60-77. PMID 25638756 DOI: 10.1016/J.Neuroimage.2015.01.043  0.46
2015 Hamid L, Aydin Ü, Wolters C, Stephani U, Siniatchkin M, Galka A. MEG-EEG fusion by Kalman filtering within a source analysis framework. Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual International Conference. 2013: 4819-22. PMID 24110813 DOI: 10.1109/EMBC.2013.6610626  0.325
2015 Hamid L, Aydin Ü, Wolters C, Stephani U, Siniatchkin M, Galka A. MEG-EEG fusion by Kalman filtering within a source analysis framework. Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual International Conference. 2013: 4819-22. PMID 24110813 DOI: 10.1109/EMBC.2013.6610626  0.325
2015 Nüßing A, Wolters CH, Brinck H, Engwer C. Patient specific simulation of brain stimulation using the unfitted discontinuous galerkin method Brain Stimulation. 8: 352. DOI: 10.1016/J.Brs.2015.01.137  0.329
2014 Vorwerk J, Cho JH, Rampp S, Hamer H, Knösche TR, Wolters CH. A guideline for head volume conductor modeling in EEG and MEG. Neuroimage. 100: 590-607. PMID 24971512 DOI: 10.1016/J.Neuroimage.2014.06.040  0.447
2014 Rampersad SM, Janssen AM, Lucka F, Aydin Ãœ, Lanfer B, Lew S, Wolters CH, Stegeman DF, Oostendorp TF. Simulating transcranial direct current stimulation with a detailed anisotropic human head model. Ieee Transactions On Neural Systems and Rehabilitation Engineering : a Publication of the Ieee Engineering in Medicine and Biology Society. 22: 441-52. PMID 24760939 DOI: 10.1109/Tnsre.2014.2308997  0.419
2014 Aydin Ü, Vorwerk J, Küpper P, Heers M, Kugel H, Galka A, Hamid L, Wellmer J, Kellinghaus C, Rampp S, Wolters CH. Combining EEG and MEG for the reconstruction of epileptic activity using a calibrated realistic volume conductor model. Plos One. 9: e93154. PMID 24671208 DOI: 10.1371/Journal.Pone.0093154  0.459
2014 Wagner S, Rampersad SM, Aydin Ãœ, Vorwerk J, Oostendorp TF, Neuling T, Herrmann CS, Stegeman DF, Wolters CH. Investigation of tDCS volume conduction effects in a highly realistic head model. Journal of Neural Engineering. 11: 016002. PMID 24310982 DOI: 10.1088/1741-2560/11/1/016002  0.666
2014 Aydin Ü, Vorwerk J, Duempelmann M, Kuepper P, Kugel H, Wellmer J, Kellinghaus C, Haueisen J, Rampp S, Stefan H, Wolters C. P806: Effects of spike averaging on EEG, MEG and combined EEG/MEG source analysis of epileptic activity Clinical Neurophysiology. 125: S258. DOI: 10.1016/S1388-2457(14)50842-5  0.359
2013 He BJ, Nolte G, Nagata K, Takano D, Yamazaki T, Fujimaki Y, Maeda T, Satoh Y, Heckers S, George MS, Lopes da Silva F, de Munck JC, Van Houdt PJ, Verdaasdonk RM, Ossenblok P, ... ... Wolters CH, ... ... Wolters C, ... ... Wolters CH, ... ... Wolters C, ... ... Wolters CH, ... ... Wolters C, ... ... Wolters C, ... ... Wolters CH, ... ... Wolters C, ... ... Wolters CH, ... ... Wolters CH, et al. Abstracts of Presentations at the International Conference on Basic and Clinical Multimodal Imaging (BaCI), a Joint Conference of the International Society for Neuroimaging in Psychiatry (ISNIP), the International Society for Functional Source Imaging (ISFSI), the International Society for Bioelectromagnetism (ISBEM), the International Society for Brain Electromagnetic Topography (ISBET), and the EEG and Clinical Neuroscience Society (ECNS), in Geneva, Switzerland, September 5-8, 2013. Clinical Eeg and Neuroscience. PMID 24368763 DOI: 10.1177/1550059413507209  0.616
2013 Janssen AM, Rampersad SM, Lucka F, Lanfer B, Lew S, Aydin U, Wolters CH, Stegeman DF, Oostendorp TF. The influence of sulcus width on simulated electric fields induced by transcranial magnetic stimulation. Physics in Medicine and Biology. 58: 4881-96. PMID 23787706 DOI: 10.1088/0031-9155/58/14/4881  0.36
2013 Lew S, Sliva DD, Choe MS, Grant PE, Okada Y, Wolters CH, Hämäläinen MS. Effects of sutures and fontanels on MEG and EEG source analysis in a realistic infant head model. Neuroimage. 76: 282-93. PMID 23531680 DOI: 10.1016/J.Neuroimage.2013.03.017  0.438
2013 Dannhauer M, Lämmel E, Wolters CH, Knösche TR. Spatio-temporal regularization in linear distributed source reconstruction from EEG/MEG: a critical evaluation. Brain Topography. 26: 229-46. PMID 23112100 DOI: 10.1007/S10548-012-0263-9  0.381
2013 Lanfer B, Röer C, Scherg M, Rampp S, Kellinghaus C, Wolters C. Influence of a silastic ECoG grid on EEG/ECoG based source analysis. Brain Topography. 26: 212-28. PMID 22941500 DOI: 10.1007/S10548-012-0251-0  0.469
2013 Knoesche TR, Lanfer B, Dannhauer M, Wolters CH. Modelling the human skull using FEM - effects of errors and simplifications Neurophysiologie Clinique-Clinical Neurophysiology. 43: 307-307. DOI: 10.1016/J.Neucli.2012.11.027  0.389
2012 Wagner S, Rampersad S, Aydin U, Vorwerk J, Neuling T, Herrmann CS, Stegeman D, Wolters CH. Volume conduction effects in tDCS using a 1mm geometry-adapted hexahedral finite element head model. Biomedizinische Technik. Biomedical Engineering. 57. PMID 23096321 DOI: 10.1515/Bmt-2012-4072  0.628
2012 Vorwerk J, Clerc M, Burger M, Wolters CH. Comparison of boundary element and finite element approaches to the EEG forward problem. Biomedizinische Technik. Biomedical Engineering. 57. PMID 23096316 DOI: 10.1515/Bmt-2012-4152  0.444
2012 Vorwerk J, Lanfer B, Grüne F, Wolters CH. Validation and Application of Realistic Head Modelling to MEG. Biomedizinische Technik. Biomedical Engineering. 57. PMID 23096300 DOI: 10.1515/Bmt-2012-4151  0.453
2012 Neuling T, Wagner S, Wolters CH, Zaehle T, Herrmann CS. Finite-Element Model Predicts Current Density Distribution for Clinical Applications of tDCS and tACS. Frontiers in Psychiatry. 3: 83. PMID 23015792 DOI: 10.3389/Fpsyt.2012.00083  0.64
2012 Neuling T, Rach S, Wagner S, Wolters CH, Herrmann CS. Good vibrations: oscillatory phase shapes perception. Neuroimage. 63: 771-8. PMID 22836177 DOI: 10.1016/J.Neuroimage.2012.07.024  0.587
2012 Lanfer B, Scherg M, Dannhauer M, Knösche TR, Burger M, Wolters CH. Influences of skull segmentation inaccuracies on EEG source analysis. Neuroimage. 62: 418-31. PMID 22584227 DOI: 10.1016/J.Neuroimage.2012.05.006  0.439
2012 Lucka F, Pursiainen S, Burger M, Wolters CH. Hierarchical Bayesian inference for the EEG inverse problem using realistic FE head models: depth localization and source separation for focal primary currents. Neuroimage. 61: 1364-82. PMID 22537599 DOI: 10.1016/J.Neuroimage.2012.04.017  0.436
2012 Pursiainen S, Lucka F, Wolters CH. Complete electrode model in EEG: relationship and differences to the point electrode model. Physics in Medicine and Biology. 57: 999-1017. PMID 22297396 DOI: 10.1088/0031-9155/57/4/999  0.417
2012 Sonntag H, Haueisen J, Lau S, Eichardt R, Wolters C, Vorwerk J, Grasedyck L, Güllmar D. Influence of finite element discretization on the EEG/MEG forward solution in rabbits Biomedical Engineering / Biomedizinische Technik. 57. DOI: 10.1515/Bmt-2012-4504  0.382
2012 Wagner S, Lucka F, Burger M, Grasedyck L, Haueisen J, Wolters CH. Comparison of direct and reciprocal forward modeling approaches in EEG source analysis Biomedical Engineering / Biomedizinische Technik. 57. DOI: 10.1515/Bmt-2012-4069  0.438
2012 Lanfer B, Paul-Jordanov I, Scherg M, Wolters CH. Influence of interior cerebrospinal fluid compartments on EEG source analysis Biomedizinische Technik. 57: 623-626. DOI: 10.1515/Bmt-2012-4020  0.322
2012 Pursiainen S, Lucka F, Wolters CH. Corrigendum: Complete electrode model in EEG: relationship and differences to the point electrode model Physics in Medicine and Biology. 58: 185-185. DOI: 10.1088/0031-9155/58/1/185  0.357
2011 Dannhauer M, Lanfer B, Wolters CH, Knösche TR. Modeling of the human skull in EEG source analysis. Human Brain Mapping. 32: 1383-99. PMID 20690140 DOI: 10.1002/Hbm.21114  0.418
2011 Janssen A, Oostendorp T, Rampersad S, Wolters C, Stegeman D. PTMS56 Volume conductor modeling of the effects of transcranial magnetic stimulation Clinical Neurophysiology. 122: S196. DOI: 10.1016/S1388-2457(11)60709-8  0.312
2011 Rampersad S, Oostendorp T, Janssen A, Wolters C, Stegeman D. P19.8 Determining the optimal electrode configuration for transcranial direct current stimulation: a model study Clinical Neurophysiology. 122: S142-S143. DOI: 10.1016/S1388-2457(11)60509-9  0.361
2010 Steinsträter O, Sillekens S, Junghoefer M, Burger M, Wolters CH. Sensitivity of beamformer source analysis to deficiencies in forward modeling. Human Brain Mapping. 31: 1907-27. PMID 21086549 DOI: 10.1002/Hbm.20986  0.414
2010 Sander TH, Knösche TR, Schlögl A, Kohl F, Wolters CH, Haueisen J, Trahms L. Recent advances in modeling and analysis of bioelectric and biomagnetic sources. Biomedizinische Technik. Biomedical Engineering. 55: 65-76. PMID 20367324 DOI: 10.1515/Bmt.2010.027  0.418
2009 Lew S, Wolters CH, Dierkes T, Röer C, Macleod RS. Accuracy and run-time comparison for different potential approaches and iterative solvers in finite element method based EEG source analysis. Applied Numerical Mathematics : Transactions of Imacs. 59: 1970-1988. PMID 20161462 DOI: 10.1016/J.Apnum.2009.02.006  0.473
2009 Drechsler F, Wolters CH, Dierkes T, Si H, Grasedyck L. A full subtraction approach for finite element method based source analysis using constrained Delaunay tetrahedralisation. Neuroimage. 46: 1055-65. PMID 19264145 DOI: 10.1016/J.Neuroimage.2009.02.024  0.429
2009 Lew S, Wolters CH, Anwander A, Makeig S, MacLeod RS. Improved EEG source analysis using low-resolution conductivity estimation in a four-compartment finite element head model. Human Brain Mapping. 30: 2862-78. PMID 19117275 DOI: 10.1002/Hbm.20714  0.469
2009 Rullmann M, Anwander A, Dannhauer M, Warfield SK, Duffy FH, Wolters CH. EEG source analysis of epileptiform activity using a 1 mm anisotropic hexahedra finite element head model. Neuroimage. 44: 399-410. PMID 18848896 DOI: 10.1016/J.Neuroimage.2008.09.009  0.495
2009 Dannhauer M, Knösche TR, Lanfer B, Wolters C. Skull tissue conductivity modeling affects forward and inverse solution: an EEG simulation study across subjects Neuroimage. 47. DOI: 10.1016/S1053-8119(09)70472-0  0.331
2008 Oostendorp TF, Hengeveld YA, Wolters CH, Stinstra J, van Elswijk G, Stegeman DF. Modeling transcranial DC stimulation. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 2008: 4226-9. PMID 19163645 DOI: 10.1109/IEMBS.2008.4650142  0.342
2007 Wolters CH, Anwander A, Berti G, Hartmann U. Geometry-adapted hexahedral meshes improve accuracy of finite-element-method-based EEG source analysis. Ieee Transactions On Bio-Medical Engineering. 54: 1446-53. PMID 17694865 DOI: 10.1109/Tbme.2007.890736  0.426
2007 Wolters CH, Köstler H, Möller C, Härdtlein J, Grasedyck L, Hackbusch W. Numerical Mathematics of the subtraction method for the modeling of a current dipole in EEG source reconstruction using finite element head models Siam Journal On Scientific Computing. 30: 24-45. DOI: 10.1137/060659053  0.437
2006 Güllmar D, Haueisen J, Eiselt M, Giessler F, Flemming L, Anwander A, Knösche TR, Wolters CH, Dümpelmann M, Tuch DS, Reichenbach JR. Influence of anisotropic conductivity on EEG source reconstruction: investigations in a rabbit model. Ieee Transactions On Bio-Medical Engineering. 53: 1841-50. PMID 16941840 DOI: 10.1109/Tbme.2006.876641  0.428
2006 Wolters CH, Anwander A, Tricoche X, Weinstein D, Koch MA, MacLeod RS. Influence of tissue conductivity anisotropy on EEG/MEG field and return current computation in a realistic head model: a simulation and visualization study using high-resolution finite element modeling. Neuroimage. 30: 813-26. PMID 16364662 DOI: 10.1016/J.Neuroimage.2005.10.014  0.473
2004 Wolters CH, Anwander A, Maess B, Macleod RS, Friederici AD. The influence of volume conduction effects on the EEG/MEG reconstruction of the sources of the Early Left Anterior Negativity. Conference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference. 5: 3569-72. PMID 17271062 DOI: 10.1109/IEMBS.2004.1404003  0.491
2004 Wolters CH, Grasedyck L, Hackbusch W. Efficient computation of lead field bases and influence matrix for the FEM-based EEG and MEG inverse problem Inverse Problems. 20: 1099-1116. DOI: 10.1088/0266-5611/20/4/007  0.443
2002 Wolters CH, Kuhn M, Anwander A, Reitzinger S. A parallel algebraic multigrid solver for finite element method based source localization in the human brain Computing and Visualization in Science. 5: 165-177. DOI: 10.1007/S00791-002-0098-0  0.39
1999 Wolters CH, Beckmann RF, Rienäcker A, Buchner H. Comparing regularized and non-regularized nonlinear dipole fit methods: a study in a simulated sulcus structure. Brain Topography. 12: 3-18. PMID 10582561 DOI: 10.1023/A:1022281005608  0.343
Show low-probability matches.