2016 |
Becker EM, Farsoni AT. A multi-panel direction-sensitive gamma-ray detector for low-altitude radiological searches Nuclear Instruments and Methods in Physics Research, Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 836: 13-21. DOI: 10.1016/j.nima.2016.08.011 |
0.312 |
|
2015 |
Xiao W, Farsoni AT, Yang H, Hamby DM. Model-based pulse deconvolution method for NaI(Tl) detectors Nuclear Instruments and Methods in Physics Research, Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 769: 5-8. DOI: 10.1016/J.Nima.2014.09.034 |
0.483 |
|
2014 |
Xiao W, Farsoni AT, Yang H, Hamby DH. A new pulse model for NaI(Tl) detection systems Nuclear Instruments and Methods in Physics Research, Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 763: 170-173. DOI: 10.1016/J.Nima.2014.06.022 |
0.438 |
|
2014 |
Becker EM, Farsoni AT. Wireless, low-cost, FPGA-based miniature gamma ray spectrometer Nuclear Instruments and Methods in Physics Research, Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 761: 99-104. DOI: 10.1016/j.nima.2014.05.096 |
0.326 |
|
2014 |
Alemayehu B, Farsoni AT, Ranjbar L, Becker EM. A well-type phoswich detector for nuclear explosion monitoring Journal of Radioanalytical and Nuclear Chemistry. 301: 323-332. DOI: 10.1007/s10967-014-3182-2 |
0.419 |
|
2013 |
Farsoni AT, Alemayehu B, Alhawsawi A, Becker EM. A phoswich detector with compton suppression capability for radioxenon measurements Ieee Transactions On Nuclear Science. 60: 456-464. DOI: 10.1109/TNS.2012.2226606 |
0.494 |
|
2013 |
Farsoni AT, Alemayehu B, Alhawsawi A, Becker EM. Real-time pulse-shape discrimination and beta-gamma coincidence detection in field-programmable gate array Nuclear Instruments and Methods in Physics Research, Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 712: 75-82. DOI: 10.1016/j.nima.2013.02.003 |
0.567 |
|
2013 |
Farsoni AT, Alemayehu B, Alhawsawi A, Becker EM. A compton-suppressed phoswich detector for gamma spectroscopy Journal of Radioanalytical and Nuclear Chemistry. 296: 63-68. DOI: 10.1007/s10967-012-2009-2 |
0.46 |
|
2012 |
Farsoni AT, Alemayehu B, Alhawsawi A. A Compton-suppressed phoswich detector for radioxenon measurements Ieee Nuclear Science Symposium Conference Record. 2208-2213. DOI: 10.1109/NSSMIC.2011.6154451 |
0.386 |
|
2007 |
Farsoni AT, Hamby DM. A system for simultaneous beta and gamma spectroscopy Nuclear Instruments and Methods in Physics Research, Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 578: 528-536. DOI: 10.1016/J.Nima.2007.06.020 |
0.481 |
|
2005 |
Farsoni AT, Hamby DM. MCNP analysis of a multilayer phoswich detector for β-particle dosimetry and spectroscopy Nuclear Instruments and Methods in Physics Research, Section a: Accelerators, Spectrometers, Detectors and Associated Equipment. 555: 225-230. DOI: 10.1016/J.Nima.2005.09.025 |
0.469 |
|