Year |
Citation |
Score |
1999 |
Hettl P, Angloher G, Feilitzsch FV, Höhne J, Jochum J, Kraus H, Mössbauer RL. High-resolution X-ray spectroscopy with superconducting tunnel junctions X-Ray Spectrometry. 28: 309-311. |
0.421 |
|
1994 |
Jochum J, Kraus H, Gutsche M, Kemmather B, Feilitzsch Fv, Mössbauer RL. Electronic noise of superconducting tunnel junction detectors Nuclear Inst. and Methods in Physics Research, A. 338: 458-466. DOI: 10.1016/0168-9002(94)91331-5 |
0.467 |
|
1993 |
Forster G, Ferger P, Feilitzsch Fv, Mössbauer RL. Calorimetric particle detectors with superconducting absorber materials Nuclear Inst. and Methods in Physics Research, A. 324: 491-495. DOI: 10.1016/0168-9002(93)91053-P |
0.349 |
|
1993 |
Kraus H, Jochum J, Kemmather B, Gutsche M, Feilitzsch Fv, Mössbauer RL. High resolution X-ray spectroscopy with superconducting tunnel junctions Nuclear Inst. and Methods in Physics Research, A. 326: 172-179. DOI: 10.1016/0168-9002(93)90348-L |
0.592 |
|
1992 |
Kraus H, Jochum J, Kemmather B, Gutsche M, Feilitzsch Fv, Mössbauer RL. Phonon and quasiparticle mediated detection of X-rays and α-particles with superconducting tunnel junctions Nuclear Inst. and Methods in Physics Research, A. 315: 213-222. DOI: 10.1016/0168-9002(92)90706-A |
0.602 |
|
1991 |
Peterreins T, Jochum J, Pröbst F, Feilitzsch FV, Kraus H, Mössbauer RL. Nonequilibrium phonon detectors Journal of Applied Physics. 69: 1791-1804. DOI: 10.1063/1.347233 |
0.59 |
|
1989 |
Kraus H, von Feilitzsch F, Jochum J, Mössbauer RL, Peterreins T, Pröbst F. Quasiparticle trapping in a superconductive detector system exhibiting high energy and position resolution Physics Letters B. 231: 195-202. DOI: 10.1016/0370-2693(89)90139-1 |
0.561 |
|
1988 |
Peterreins T, Pröbst F, Von Feilitzsch F, Mössbauer RL, Kraus H. A new detector of nuclear radiation based on ballistic phonon propagation in single crystals at low temperatures Physics Letters B. 202: 161-168. DOI: 10.1016/0370-2693(88)90872-6 |
0.557 |
|
1987 |
Nienhaus GU, Drepper F, Parak F, Mössbauer RL, Bade D, Hoppe W. A multiwire proportional counter with spherical drift chamber for protein crystallography with X-rays and gamma-rays Nuclear Inst. and Methods in Physics Research, A. 256: 581-586. DOI: 10.1016/0168-9002(87)90305-6 |
0.403 |
|
1986 |
Kraus H, Peterreins TH, Probst F, Feilitzsch FV, Mössbauer RL, Zacek V, Umlauf E. High-resolution x-ray detection with superconducting tunnel junctions Epl. 1: 161-166. DOI: 10.1209/0295-5075/1/4/002 |
0.561 |
|
1982 |
Bade D, Parak F, Mössbauer RL, Hoppe W, Levai N, Charpak G. Development of a multiwire proportional chamber as an area sensitive detector for X-ray protein crystallography Nuclear Instruments and Methods in Physics Research. 201: 193-196. DOI: 10.1016/0167-5087(82)90026-6 |
0.353 |
|
1981 |
Mayo KH, Parak F, Mössbauer RL. Observations of elastic and quasi-elastic nuclear gamma resonance absorption in hemoglobin crystals Physics Letters A. 82: 468-470. DOI: 10.1016/0375-9601(81)90283-8 |
0.441 |
|
1967 |
Maletta H, Heidrich W, Mössbauer RL. Dependence of concentration of the isomer shift of divalent 151Eu in CaF2 Physics Letters A. 25: 295-296. |
0.302 |
|
1960 |
Mössbauer RL, Wiedemann WH. Kernresonanzabsorption nicht Doppler-verbreiterter Gammastrahlung in Re187 Zeitschrift FüR Physik. 159: 33-48. DOI: 10.1007/BF01338458 |
0.379 |
|
Show low-probability matches. |