Anja Boisen - Publications

Affiliations: 
Technical University of Denmark, Kongens Lyngby, Denmark 

162 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2020 Rangacharya VP, Wu K, Larsen PE, Thamdrup LHE, Ilchenko O, Hwu ET, Rindzevicius T, Boisen A. Quantifying Optical Absorption of Single Plasmonic Nanoparticles and Nanoparticle Dimers Using Micro String Resonators. Acs Sensors. PMID 32529825 DOI: 10.1021/Acssensors.0C00591  0.332
2020 Kamguyan K, Thamdrup LHE, Vaut L, Nielsen LH, Zor K, Boisen A. Development and characterization of a PDMS-based masking method for microfabricated Oral drug delivery devices. Biomedical Microdevices. 22: 35. PMID 32419094 DOI: 10.1007/S10544-020-00490-8  0.31
2020 Okeyo PO, Larsen PE, Kissi EO, Ajalloueian F, Rades T, Rantanen J, Boisen A. Single particles as resonators for thermomechanical analysis. Nature Communications. 11: 1235. PMID 32144254 DOI: 10.1038/S41467-020-15028-Y  0.318
2020 Juhlin L, Mikaelsson T, Hakonen A, Schmidt MS, Rindzevicius T, Boisen A, Käll M, Andersson PO. Selective surface-enhanced Raman scattering detection of Tabun, VX and Cyclosarin nerve agents using 4-pyridine amide oxime functionalized gold nanopillars. Talanta. 211: 120721. PMID 32070593 DOI: 10.1016/J.Talanta.2020.120721  0.328
2020 Karl M, Thamdrup LHE, Rantanen J, Boisen A, Rades T. Temperature-Modulated Micromechanical Thermal Analysis with Microstring Resonators Detects Multiple Coherent Features of Small Molecule Glass Transition. Sensors (Basel, Switzerland). 20. PMID 32070014 DOI: 10.3390/S20041019  0.352
2020 Viehrig M, Rajendran ST, Sanger K, Schmidt MS, Alstrøm TS, Rindzevicius T, Zór K, Boisen A. Quantitative SERS Assay on a Single Chip Enabled by Electrochemically Assisted Regeneration: A Method for Detection of Melamine in Milk. Analytical Chemistry. PMID 31985206 DOI: 10.1021/Acs.Analchem.9B05060  0.368
2020 Rostami S, Zór K, Zhai DS, Viehrig M, Morelli L, Mehdinia A, Smedsgaard J, Rindzevicius T, Boisen A. High-throughput label-free detection of Ochratoxin A in wine using supported liquid membrane extraction and Ag-capped silicon nanopillar SERS substrates Food Control. 113: 107183. DOI: 10.1016/J.Foodcont.2020.107183  0.309
2019 Nguyen LQ, Larsen PE, Larsen T, Goswami SB, Villanueva LG, Boisen A, Keller SS. Pyrolytic carbon resonators for micromechanical thermal analysis. Microsystems & Nanoengineering. 5: 58. PMID 31646000 DOI: 10.1038/S41378-019-0094-X  0.342
2019 Thoppe Rajendran S, Scarano E, Bergkamp MH, Capria AM, Cheng CH, Sanger K, Ferrari G, Nielsen LH, Hwu ET, Zór K, Boisen A. Modular, lightweight, wireless potentiostat-on-a-disc (PoD) for elec-trochemical detection in centrifugal microfluidics. Analytical Chemistry. PMID 31335122 DOI: 10.1021/Acs.Analchem.9B02026  0.322
2019 Samaeifar F, Casci Ceccacci A, Bose Goswami S, Hagner Nielsen L, Afifi A, Zór K, Boisen A. Evaluation of the solid state form of tadalafil in sub-micron thin films using nanomechanical infrared spectroscopy. International Journal of Pharmaceutics. 565: 227-232. PMID 31077764 DOI: 10.1016/J.Ijpharm.2019.05.010  0.302
2019 Casci Ceccacci A, Cagliani A, Marizza P, Schmid S, Boisen A. Thin Film Analysis by Nanomechanical Infrared Spectroscopy. Acs Omega. 4: 7628-7635. PMID 31058251 DOI: 10.1021/acsomega.9b00276  0.616
2019 Andreasen SZ, Sanger K, Jendresen CB, Nielsen AT, Emnéus J, Boisen A, Zór K. Extraction, Enrichment, and in situ Electrochemical Detection on Lab-on-a-Disc: Monitoring the Production of a Bacterial Secondary Metabolite. Acs Sensors. 4: 398-405. PMID 30525464 DOI: 10.1021/Acssensors.8B01277  0.31
2019 Nguyen LQ, Larsen PE, Bishnoi S, Boisen A, Keller SS. Fabrication of fully suspended pyrolytic carbon string resonators for characterization of drug nano- and microparticles Sensors and Actuators a: Physical. 288: 194-203. DOI: 10.1016/J.Sna.2019.02.002  0.396
2018 Durucan O, Wu K, Viehrig M, Rindzevicius T, Boisen A. Nanopillar-Assisted SERS Chromatography. Acs Sensors. PMID 30525481 DOI: 10.1021/Acssensors.8B00887  0.349
2018 Karl M, Larsen PE, Rangacharya V, Hwu ET, Rantanen J, Boisen A, Rades T. Ultra Sensitive Micro String Resonators for Solid State Thermomechanical Analysis of Small and Large Molecules. Journal of the American Chemical Society. PMID 30468581 DOI: 10.1021/Jacs.8B09034  0.361
2018 Viehrig M, Thilsted AH, Matteucci M, Wu K, Catak D, Schmidt MS, Zór K, Boisen A. Injection molded microfluidic device for SERS sensing using embedded Au-capped polymer nanocones. Acs Applied Materials & Interfaces. PMID 30277378 DOI: 10.1021/Acsami.8B13424  0.38
2018 Hakonen A, Wu K, Stenbæk Schmidt M, Andersson PO, Boisen A, Rindzevicius T. Detecting forensic substances using commercially available SERS substrates and handheld Raman spectrometers. Talanta. 189: 649-652. PMID 30086972 DOI: 10.1016/J.Talanta.2018.07.009  0.334
2018 Morelli L, Serioli L, Centorbi FA, Jendresen CB, Matteucci M, Ilchenko O, Demarchi D, Nielsen AT, Zór K, Boisen A. Injection molded lab-on-a-disc platform for screening of genetically modified E. coli using liquid-liquid extraction and surface enhanced Raman scattering. Lab On a Chip. 18: 869-877. PMID 29450440 DOI: 10.1039/C7Lc01217A  0.301
2018 Uddin R, Donolato M, Hwu E, Hansen MF, Boisen A. Combined detection of C-reactive protein and PBMC quantification from whole blood in an integrated lab-on-a-disc microfluidic platform Sensors and Actuators B: Chemical. 272: 634-642. DOI: 10.1016/J.Snb.2018.07.015  0.304
2018 Alves GMA, Goswami SB, Mansano RD, Boisen A. Using microcantilever sensors to measure poly(lactic-co-glycolic acid) plasticization by moisture uptake Polymer Testing. 65: 407-413. DOI: 10.1016/J.Polymertesting.2017.12.017  0.315
2018 Quang LN, Larsen PE, Boisen A, Keller SS. Tailoring stress in pyrolytic carbon for fabrication of nanomechanical string resonators Carbon. 133: 358-368. DOI: 10.1016/J.Carbon.2018.03.005  0.325
2017 Sanger K, Durucan O, Wu K, Thilsted AH, Heiskanen AR, Rindzevicius T, Schmidt MS, Zór K, Boisen A. Large-scale, Lithography-free Production of Transparent Nanostructured Surface for Dual-functional Electrochemical and SERS Sensing. Acs Sensors. PMID 29164868 DOI: 10.1021/Acssensors.7B00783  0.339
2017 Durucan O, Rindzevicius T, Schmidt MS, Matteucci M, Boisen A. Nanopillar Filters for Surface-Enhanced Raman Spectroscopy. Acs Sensors. 2: 1400-1404. PMID 28956441 DOI: 10.1021/Acssensors.7B00499  0.326
2017 Ashley J, Wu K, Hansen MF, Schmidt MS, Boisen A, Sun Y. Rapid and Quantitative Detection of Trace Level Cloxacillin in Food Samples Using Magnetic MIP Extraction and SERS Nanopillars. Analytical Chemistry. PMID 28952718 DOI: 10.1021/Acs.Analchem.7B02725  0.349
2017 Hakonen A, Wang F, Andersson PO, Wingfors H, Rindzevicius T, Schmidt MS, Soma VR, Xu S, Li Y, Boisen A, Wu H. Hand-Held Femtogram Detection of Hazardous Picric Acid with Hydrophobic Ag Nanopillar SERS Substrates and Mechanism of Elasto-Capillarity. Acs Sensors. 2: 198-202. PMID 28723138 DOI: 10.1021/Acssensors.6B00749  0.309
2017 Kurek M, Carnoy M, Larsen PE, Nielsen LH, Hansen O, Rades T, Schmid S, Boisen A. Nanomechanical Infrared Spectroscopy with Vibrating Filters for Pharmaceutical Analysis. Angewandte Chemie (International Ed. in English). PMID 28266106 DOI: 10.1002/Anie.201700052  0.661
2017 Sadeghi P, Wu K, Rindzevicius T, Boisen A, Schmid S. Fabrication and characterization of Au dimer antennas on glass pillars with enhanced plasmonic response Nanophotonics. 7: 497-505. DOI: 10.1515/Nanoph-2017-0011  0.655
2017 Larsen T, Schmid S, Dohn S, Sader JE, Boisen A, Villanueva LG. Position and mode dependent optical detection back-action in cantilever beam resonators Journal of Micromechanics and Microengineering. 27: 035006. DOI: 10.1088/1361-6439/Aa591E  0.665
2017 Rindzevicius T, Barten J, Vorobiev M, Schmidt MS, Castillo JJ, Boisen A. Detection of surface-linked polychlorinated biphenyls using surface-enhanced Raman scattering spectroscopy Vibrational Spectroscopy. 90: 1-6. DOI: 10.1016/J.Vibspec.2017.02.004  0.332
2017 Sanger K, Zór K, Bille Jendresen C, Heiskanen A, Amato L, Toftgaard Nielsen A, Boisen A. Lab-on-a-disc platform for screening of genetically modified E. coli cells via cell-free electrochemical detection of p-Coumaric acid Sensors and Actuators B: Chemical. 253: 999-1005. DOI: 10.1016/J.Snb.2017.06.184  0.303
2017 Ceccacci AC, Chen C, Hwu E, Morelli L, Bose S, Bosco FG, Schmid S, Boisen A. Blu-Ray-based micromechanical characterization platform for biopolymer degradation assessment Sensors and Actuators B: Chemical. 241: 1303-1309. DOI: 10.1016/J.Snb.2016.09.190  0.692
2017 Morelli L, Jendresen CB, Zor K, Rindzevicius T, Schmidt MS, Nielsen AT, Boisen A. Detection of p-coumaric Acid from Cell Supernatant Using Surface Enhanced Raman Scattering Procedia Technology. 27: 190-192. DOI: 10.1016/J.Protcy.2017.04.081  0.324
2017 Wu K, Rindzevicius T, Schmidt MS, Thilsted AH, Boisen A. Optimizing silver-capped silicon nanopillars to simultaneously realize macroscopic, practical-level SERS signal reproducibility and high enhancement at low costs Journal of Raman Spectroscopy. 48: 1808-1818. DOI: 10.1002/Jrs.5255  0.342
2016 Thilsted AH, Pan JY, Wu K, Zór K, Rindzevicius T, Schmidt MS, Boisen A. Lithography-Free Fabrication of Silica Nanocylinders with Suspended Gold Nanorings for LSPR-Based Sensing. Small (Weinheim An Der Bergstrasse, Germany). PMID 27709773 DOI: 10.1002/Smll.201602299  0.382
2016 Kurek M, Larsen FK, Larsen PE, Schmid S, Boisen A, Keller SS. Nanomechanical Pyrolytic Carbon Resonators: Novel Fabrication Method and Characterization of Mechanical Properties. Sensors (Basel, Switzerland). 16. PMID 27428980 DOI: 10.3390/S16071097  0.668
2016 Li T, Wu K, Rindzevicius T, Wang Z, Schulte L, Schmidt MS, Boisen A, Ndoni S. Wafer-scale Nanopillars Derived from Block Copolymer Lithography for Surface-enhanced Raman Spectroscopy. Acs Applied Materials & Interfaces. PMID 27254397 DOI: 10.1021/Acsami.6B05431  0.355
2016 Uddin R, Burger R, Donolato M, Fock J, Creagh M, Hansen MF, Boisen A. Lab-on-a-disc agglutination assay for protein detection by optomagnetic readout and optical imaging using nano- and micro-sized magnetic beads. Biosensors & Bioelectronics. 85: 351-357. PMID 27183287 DOI: 10.1016/J.Bios.2016.05.023  0.319
2016 Brawley GA, Vanner MR, Larsen PE, Schmid S, Boisen A, Bowen WP. Nonlinear optomechanical measurement of mechanical motion. Nature Communications. 7: 10988. PMID 26996234 DOI: 10.1038/Ncomms10988  0.632
2016 Burger R, Amato L, Boisen A. Detection methods for centrifugal microfluidic platforms. Biosensors & Bioelectronics. 76: 54-67. PMID 26166363 DOI: 10.1016/J.Bios.2015.06.075  0.304
2016 Castillo JJ, Rozo CE, Bertel L, Rindzevicius T, Mendez-Sanchez SC, Ortega FM, Boisen A. Orientation of pterin-6-carboxylic acid on gold capped silicon nanopillars platforms: Surface enhanced Raman spectroscopy and density functional theory studies Journal of the Brazilian Chemical Society. 27: 971-977. DOI: 10.5935/0103-5053.20150352  0.304
2016 Andersen AJ, Yamada S, Pramodkumar EK, Andresen TL, Boisen A, Schmid S. Nanomechanical IR spectroscopy for fast analysis of liquid-dispersed engineered nanomaterials Sensors and Actuators, B: Chemical. 233: 667-673. DOI: 10.1016/J.Snb.2016.04.002  0.667
2016 Thilsted AH, Pan JY, Wu K, Zór K, Rindzevicius T, Schmidt MS, Boisen A. Nanocylinders: Lithography-Free Fabrication of Silica Nanocylinders with Suspended Gold Nanorings for LSPR-Based Sensing (Small 48/2016) Small. 12: 6636-6636. DOI: 10.1002/Smll.201670253  0.346
2015 Palla M, Bosco FG, Yang J, Rindzevicius T, Alstrom TS, Schmidt MS, Lin Q, Ju J, Boisen A. Mathematical Model for Biomolecular Quantification Using Large-Area Surface-Enhanced Raman Spectroscopy Mapping. Rsc Advances. 5: 85845-85853. PMID 27148445 DOI: 10.1039/C5Ra16108H  0.315
2015 Hakonen A, Rindzevicius T, Schmidt MS, Andersson PO, Juhlin L, Svedendahl M, Boisen A, Käll M. Detection of nerve gases using surface-enhanced Raman scattering substrates with high droplet adhesion. Nanoscale. PMID 26676552 DOI: 10.1039/C5Nr06524K  0.318
2015 Antunes P, Watterson D, Parmvi M, Burger R, Boisen A, Young P, Cooper MA, Hansen MF, Ranzoni A, Donolato M. Quantification of NS1 dengue biomarker in serum via optomagnetic nanocluster detection. Scientific Reports. 5: 16145. PMID 26536916 DOI: 10.1038/Srep16145  0.308
2015 Donolato M, Antunes P, de la Torre TZ, Hwu ET, Chen CH, Burger R, Rizzi G, Bosco FG, Strømme M, Boisen A, Hansen MF. Quantification of rolling circle amplified DNA using magnetic nanobeads and a Blu-ray optical pick-up unit. Biosensors & Bioelectronics. 67: 649-55. PMID 25453736 DOI: 10.1016/J.Bios.2014.09.097  0.317
2015 Petersen RS, Keller SS, Hansen O, Boisen A. Fabrication of Ni stamp with high aspect ratio, two-leveled, cylindrical microstructures using dry etching and electroplating Journal of Micromechanics and Microengineering. 25. DOI: 10.1088/0960-1317/25/5/055021  0.318
2015 Wu K, Rindzevicius T, Schmidt MS, Mogensen KB, Hakonen A, Boisen A. Wafer-Scale Leaning Silver Nanopillars for Molecular Detection at Ultra-Low Concentrations The Journal of Physical Chemistry C. 119: 2053-2062. DOI: 10.1021/Jp510073Y  0.305
2015 Bose S, Keller SS, Boisen A, Almdal K. Microcantilever sensors for fast analysis of enzymatic degradation of poly (d, l-lactide) Polymer Degradation and Stability. 119: 1-8. DOI: 10.1016/J.Polymdegradstab.2015.04.021  0.301
2015 Petersen RS, Mahshid R, Andersen NK, Keller SS, Hansen HN, Boisen A. Hot embossing and mechanical punching of biodegradable microcontainers for oral drug delivery Microelectronic Engineering. 133: 104-109. DOI: 10.1016/J.Mee.2014.11.009  0.318
2015 Bose S, Schmid S, Larsen T, Sylvest Keller S, Boisen A, Almdal K. Micromechanical fast quasi-static detection of α and β relaxations with nanograms of polymer Journal of Polymer Science, Part B: Polymer Physics. 53: 1035-1039. DOI: 10.1002/Polb.23745  0.656
2014 Schmid S, Wu K, Larsen PE, Rindzevicius T, Boisen A. Low-power photothermal probing of single plasmonic nanostructures with nanomechanical string resonators. Nano Letters. 14: 2318-21. PMID 24697597 DOI: 10.1021/Nl4046679  0.66
2014 Faheem Khan M, Kim S, Lee D, Schmid S, Boisen A, Thundat T. Nanomechanical identification of liquid reagents in a microfluidic channel. Lab On a Chip. 14: 1302-7. PMID 24496241 DOI: 10.1039/C3Lc51273H  0.667
2014 Schmid S, Wu K, Rindzevicius T, Boisen A. Photothermal probing of plasmonic hotspots with nanomechanical resonator Proceedings of the Ieee International Conference On Micro Electro Mechanical Systems (Mems). 1205-1208. DOI: 10.1109/MEMSYS.2014.6765864  0.632
2014 Schmid S, Bagci T, Zeuthen E, Taylor JM, Herring PK, Cassidy MC, Marcus CM, Guillermo Villanueva L, Amato B, Boisen A, Shin YC, Kong J, Sørensen AS, Usami K, Polzik ES. Single-layer graphene on silicon nitride micromembrane resonators Journal of Applied Physics. 115. DOI: 10.1063/1.4862296  0.643
2014 Bose S, Schmid S, Larsen T, Keller SS, Sommer-Larsen P, Boisen A, Almdal K. Micromechanical string resonators: Analytical tool for thermal characterization of polymers Acs Macro Letters. 3: 55-58. DOI: 10.1021/Mz400470N  0.668
2014 Castillo JJ, Rindzevicius T, Wu K, Schmidt MS, Janik KA, Boisen A, Svendsen W, Rozlosnik N, Castillo-León J. Synthesis and characterization of covalent diphenylalanine nanotube-folic acid conjugates Journal of Nanoparticle Research. 16. DOI: 10.1007/S11051-014-2525-9  0.305
2013 Bose S, Schmid S, Larsen T, Keller SS, Sommer-Larsen P, Boisen A, Almdal K. Micromechanical String Resonators: Analytical Tool for Thermal Characterization of Polymers. Acs Macro Letters. 3: 55-58. PMID 35651109 DOI: 10.1021/mz400470n  0.645
2013 Bosco FG, Bache M, Yang J, Chen CH, Hwu E-, Lin Q, Boisen A. Micromechanical PDGF recognition via lab-on-a-disc aptasensor arrays Sensors and Actuators a-Physical. 195: 154-159. PMID 24672146 DOI: 10.1016/J.Sna.2012.06.030  0.338
2013 Noeth N, Keller SS, Boisen A. Integrated cantilever-based flow sensors with tunable sensitivity for in-line monitoring of flow fluctuations in microfluidic systems. Sensors (Basel, Switzerland). 14: 229-44. PMID 24366179 DOI: 10.3390/S140100229  0.32
2013 Bache M, Bosco FG, Brøgger AL, Frøhling KB, Alstrøm TS, Hwu ET, Chen CH, Eugen-Olsen J, Hwang IS, Boisen A. Nanomechanical recognition of prognostic biomarker suPAR with DVD-ROM optical technology. Nanotechnology. 24: 444011. PMID 24113286 DOI: 10.1088/0957-4484/24/44/444011  0.309
2013 Yamada S, Schmid S, Larsen T, Hansen O, Boisen A. Photothermal infrared spectroscopy of airborne samples with mechanical string resonators. Analytical Chemistry. 85: 10531-5. PMID 24083320 DOI: 10.1021/Ac402585E  0.693
2013 Larsen T, Schmid S, Villanueva LG, Boisen A. Photothermal analysis of individual nanoparticulate samples using micromechanical resonators. Acs Nano. 7: 6188-93. PMID 23799869 DOI: 10.1021/Nn402057F  0.679
2013 Yang J, Palla M, Bosco FG, Rindzevicius T, Alstrøm TS, Schmidt MS, Boisen A, Ju J, Lin Q. Surface-enhanced Raman spectroscopy based quantitative bioassay on aptamer-functionalized nanopillars using large-area Raman mapping. Acs Nano. 7: 5350-9. PMID 23713574 DOI: 10.1021/Nn401199K  0.336
2013 Schmid S, Kurek M, Adolphsen JQ, Boisen A. Real-time single airborne nanoparticle detection with nanomechanical resonant filter-fiber. Scientific Reports. 3: 1288. PMID 23411405 DOI: 10.1038/Srep01288  0.655
2013 Schmid S, Kurek M, Adolphsen J, Boisen A. Detection of airborne nanoparticles with mechanical systems Spie Newsroom. DOI: 10.1117/2.1201305.004875  0.63
2013 Schmid S, Kurek M, Boisen A. Towards airborne nanoparticle mass spectrometry with nanomechanical string resonators Proceedings of Spie. 8725: 872525. DOI: 10.1117/12.2013682  0.664
2013 Hwu E, Chen C, Bosco FG, Wang W, Ko H, Hwang I, Boisen A, Huang K. High-performance spinning device for DVD-based micromechanical signal transduction Journal of Micromechanics and Microengineering. 23: 045016. DOI: 10.1088/0960-1317/23/4/045016  0.336
2013 Khan MF, Schmid S, Larsen PE, Davis ZJ, Yan W, Stenby EH, Boisen A. Online measurement of mass density and viscosity of pL fluid samples with suspended microchannel resonator Sensors and Actuators, B: Chemical. 185: 456-461. DOI: 10.1016/J.Snb.2013.04.095  0.653
2013 Keller SS, Bosco FG, Boisen A. Ferromagnetic shadow mask for spray coating of polymer patterns Microelectronic Engineering. 110: 427-431. DOI: 10.1016/J.Mee.2013.03.029  0.309
2012 Schmidt MS, Hübner J, Boisen A. Large area fabrication of leaning silicon nanopillars for surface enhanced Raman spectroscopy. Advanced Materials (Deerfield Beach, Fla.). 24: OP11-8. PMID 22105972 DOI: 10.1002/Adma.201103496  0.332
2012 Hwu E, Liao H, Bosco FG, Chen C, Keller SS, Boisen A, Huang K. An Astigmatic Detection System for Polymeric Cantilever-Based Sensors Journal of Sensors. 2012: 1-7. DOI: 10.1155/2012/580939  0.371
2012 Ingrosso C, Sardella E, Keller S, Striccoli M, Agostiano A, Boisen A, Curri M. Surface chemical functionalisation of epoxy photoresist-based microcantilevers with organic-coated TiO2 nanocrystals Micro & Nano Letters. 7: 337. DOI: 10.1049/Mnl.2011.0673  0.303
2012 Bosco F, Bache M, Hwu E-, Chen CH, Andersen SS, Nielsen KA, Keller SS, Jeppesen J, Hwang I-, Boisen A. Statistical analysis of DNT detection using chemically functionalized microcantilever arrays Sensors and Actuators B-Chemical. 171: 1054-1059. DOI: 10.1016/J.Snb.2012.06.033  0.38
2012 Schmidt MS, Hübner J, Boisen A. Nanopillars: Large Area Fabrication of Leaning Silicon Nanopillars for Surface Enhanced Raman Spectroscopy (Adv. Mater. 10/2012) Advanced Materials. 24: OP10-OP10. DOI: 10.1002/Adma.201290051  0.318
2011 Bosco FG, Hwu ET, Chen CH, Keller S, Bache M, Jakobsen MH, Hwang IS, Boisen A. High throughput label-free platform for statistical bio-molecular sensing. Lab On a Chip. 11: 2411-6. PMID 21623438 DOI: 10.1039/C1Lc20116F  0.345
2011 Schmidt MS, Kostesha N, Bosco F, Olsen JK, Johnsen C, Nielsen KA, Jeppesen JO, Alstrøm TS, Larsen J, Thundat T, Jakobsen MH, Boisen A. Xsense: a miniaturised multi-sensor platform for explosives detection Proceedings of Spie. 8031: 803123. DOI: 10.1117/12.884050  0.318
2011 Olsen JK, Greve A, Senesac L, Thundat T, Boisen A. Differential thermal analysis microsystem for explosive detection Proceedings of Spie. 8031. DOI: 10.1117/12.883960  0.353
2011 Bergmann R, Davis ZJ, Schmidt MS, Clausen S, Boisen A, Jensen JM, Buchner R, Stolberg-Rohr T, Jakobsen MH. Development of nanostructured protective "sight glasses" for IR gas sensors Proceedings of Spie - the International Society For Optical Engineering. 8016. DOI: 10.1117/12.883921  0.348
2011 Keller SS, Gammelgaard L, Jensen MP, Schmid S, Davis ZJ, Boisen A. Micromechanical sensors for the measurement of biopolymer degradation Proceedings of the Ieee International Conference On Micro Electro Mechanical Systems (Mems). 457-460. DOI: 10.1109/MEMSYS.2011.5734460  0.606
2011 Schmid S, Jensen KD, Nielsen KH, Boisen A. Damping mechanisms in high-Q micro and nanomechanical string resonators Physical Review B - Condensed Matter and Materials Physics. 84. DOI: 10.1103/Physrevb.84.165307  0.65
2011 Noeth N, Keller SS, Boisen A. Cantilever-based micro-particle filter with simultaneous single particle detection Journal of Micromechanics and Microengineering. 21: 054022. DOI: 10.1088/0960-1317/21/5/054022  0.3
2011 Boisen A, Dohn S, Keller SS, Schmid S, Tenje M. Cantilever-like micromechanical sensors Reports On Progress in Physics. 74: 036101. DOI: 10.1088/0034-4885/74/3/036101  0.661
2011 Larsen T, Schmid S, Grönberg L, Niskanen AO, Hassel J, Dohn S, Boisen A. Ultrasensitive string-based temperature sensors Applied Physics Letters. 98: 121901. DOI: 10.1063/1.3567012  0.667
2011 Jiang C, Ouattara L, Ingrosso C, Curri M, Krozer V, Boisen A, Jakobsen M, Johansen T. Microwave absorption properties of gold nanoparticle doped polymers Solid-State Electronics. 57: 19-22. DOI: 10.1016/J.Sse.2010.10.021  0.33
2011 Khan MF, Schmid S, Davis ZJ, Dohn S, Boisen A. Fabrication of resonant micro cantilevers with integrated transparent fluidic channel Microelectronic Engineering. 88: 2300-2303. DOI: 10.1016/J.Mee.2011.02.096  0.659
2011 Keller SS, Feidenhans’l N, Fisker-Bødker N, Soulat D, Greve A, Plackett DV, Boisen A. Fabrication of biopolymer cantilevers using nanoimprint lithography Microelectronic Engineering. 88: 2294-2296. DOI: 10.1016/J.Mee.2011.02.095  0.35
2011 Keller SS, Gammelgaard L, Jensen MP, Schmid S, Davis ZJ, Boisen A. Deposition of biopolymer films on micromechanical sensors Microelectronic Engineering. 88: 2297-2299. DOI: 10.1016/J.Mee.2011.02.093  0.659
2011 Larsen T, Keller S, Schmid S, Dohn S, Boisen A. Fabrication and characterization of SRN/SU-8 bimorph cantilevers for temperature sensing Microelectronic Engineering. 88: 2311-2313. DOI: 10.1016/J.Mee.2010.12.015  0.653
2010 Schmid S, Dohn S, Boisen A. Real-time particle mass spectrometry based on resonant micro strings. Sensors (Basel, Switzerland). 10: 8092-100. PMID 22163642 DOI: 10.3390/S100908092  0.674
2010 Tenje M, Keller S, Dohn S, Davis ZJ, Boisen A. Drift study of SU8 cantilevers in liquid and gaseous environments. Ultramicroscopy. 110: 596-8. PMID 20202757 DOI: 10.1016/J.Ultramic.2010.02.017  0.317
2010 Olsen JK, Greve A, Privorotskaya N, Senesac L, Thundat T, King WP, Boisen A. Micro-calorimetric sensor for trace explosive particle detection Proceedings of Spie - the International Society For Optical Engineering. 7679. DOI: 10.1117/12.850492  0.352
2010 Schmidt MS, Boisen A. Metal-coated silicon nanopillars with large Raman enhancement for explosives detection Proceedings of Spie. 7673: 767303. DOI: 10.1117/12.850198  0.385
2010 Bosco FG, Hwu E-, Boisen A. High throughput readout system for cantilever-based sensing of explosive compounds Proceedings of Spie. 7679: 767925. DOI: 10.1117/12.850008  0.381
2010 Noeth N, Keller SS, Boisen A. Fabrication of a cantilever-based microfluidic flow meter with nL min−1resolution Journal of Micromechanics and Microengineering. 21: 015007. DOI: 10.1088/0960-1317/21/1/015007  0.307
2010 Keller S, Haefliger D, Boisen A. Fabrication of thin SU-8 cantilevers: initial bending, release and time stability Journal of Micromechanics and Microengineering. 20: 045024. DOI: 10.1088/0960-1317/20/4/045024  0.316
2010 Dohn S, Schmid S, Amiot F, Boisen A. Position and mass determination of multiple particles using cantilever based mass sensors Applied Physics Letters. 97: 044103. DOI: 10.1063/1.3473761  0.635
2010 Schmid S, Hierold C, Boisen A. Modeling the Kelvin polarization force actuation of micro- and nanomechanical systems Journal of Applied Physics. 107: 054510. DOI: 10.1063/1.3309027  0.705
2010 Greve A, Olsen J, Privorotskaya N, Senesac L, Thundat T, King WP, Boisen A. Micro-calorimetric sensor for vapor phase explosive detection with optimized heat profile Microelectronic Engineering. 87: 696-698. DOI: 10.1016/J.Mee.2009.12.069  0.312
2010 Bosco F, Hwu E, Keller S, Greve A, Boisen A. Self-aligned cantilever positioning for on-substrate measurements using DVD pickup head Microelectronic Engineering. 87: 708-711. DOI: 10.1016/J.Mee.2009.12.064  0.361
2010 Murillo G, Davis ZJ, Keller S, Abadal G, Agusti J, Cagliani A, Noeth N, Boisen A, Barniol N. Novel SU-8 based vacuum wafer-level packaging for MEMS devices Microelectronic Engineering. 87: 1173-1176. DOI: 10.1016/J.Mee.2009.12.048  0.345
2010 Ingrosso C, Sardella E, Keller S, Dohn S, Striccoli M, Agostiano A, Boisen A, Curri ML. Surface Functionalization of Epoxy-Resist- Based Microcantilevers with Iron Oxide Nanocrystals Advanced Materials. 22: 3288-3292. DOI: 10.1002/Adma.200904013  0.31
2009 Senesac LR, Yi D, Greve A, Hales JH, Davis ZJ, Nicholson DM, Boisen A, Thundat T. Micro-differential thermal analysis detection of adsorbed explosive molecules using microfabricated bridges. The Review of Scientific Instruments. 80: 035102. PMID 19334947 DOI: 10.1063/1.3090881  0.342
2009 Datar R, Kim S, Jeon S, Hesketh P, Manalis S, Boisen A, Thundat T. Cantilever Sensors: Nanomechanical Tools for Diagnostics Mrs Bulletin. 34: 449-454. DOI: 10.1557/Mrs2009.121  0.365
2009 Greve A, Keller S, Vig AL, Kristensen A, Larsson D, Yvind K, Hvam JM, Cerruti M, Majumdar A, Boisen A. Thermoplastic microcantilevers fabricated by nanoimprint lithography Journal of Micromechanics and Microengineering. 20: 015009. DOI: 10.1088/0960-1317/20/1/015009  0.328
2009 Hales JH, Teva J, Boisen A, Davis ZJ. Longitudinal bulk acoustic mass sensor Transducers 2009 - 15th International Conference On Solid-State Sensors, Actuators and Microsystems. 311-314. DOI: 10.1063/1.3168519  0.325
2009 Larsson D, Greve A, Hvam JM, Boisen A, Yvind K. Self-mixing interferometry in vertical-cavity surface-emitting lasers for nanomechanical cantilever sensing Applied Physics Letters. 94: 091103. DOI: 10.1063/1.3086893  0.301
2009 Boisen A, Thundat T. Design & fabrication of cantilever array biosensors Materials Today. 12: 32-38. DOI: 10.1016/S1369-7021(09)70249-4  0.346
2009 Ingrosso C, Striccoli M, Agostiano A, Sardella E, Keller S, Blagoi G, Boisen A, Curri ML. Surface Functionalization of Micro Mechanical Cantilever Sensors by Organic Capped TiO2 and Fe2O3 Nanocrystals Procedia Chemistry. 1: 32-35. DOI: 10.1016/J.Proche.2009.07.008  0.341
2008 Nordström M, Keller S, Lillemose M, Johansson A, Dohn S, Haefliger D, Blagoi G, Havsteen-Jakobsen M, Boisen A. SU-8 Cantilevers for Bio/chemical Sensing; Fabrication, Characterisation and Development of Novel Read-out Methods. Sensors (Basel, Switzerland). 8: 1595-1612. PMID 27879783 DOI: 10.3390/S8031595  0.375
2008 Blagoi G, Keller S, Persson F, Boisen A, Jakobsen MH. Photochemical modification and patterning of SU-8 using anthraquinone photolinkers. Langmuir : the Acs Journal of Surfaces and Colloids. 24: 9929-32. PMID 18710270 DOI: 10.1021/La800948W  0.32
2008 Dohn S, Svendsen W, Boisen A, Hansen O. Mass and position determination of attached particles on cantilever based mass sensors. The Review of Scientific Instruments. 78: 103303. PMID 17979412 DOI: 10.1063/1.2804074  0.335
2008 Dohn S, Hansen O, Boisen A. Measurement of the resonant frequency of nano-scale cantilevers by hard contact readout Microelectronic Engineering. 85: 1390-1394. DOI: 10.1016/J.Mee.2007.12.039  0.35
2008 Lillemose M, Gammelgaard L, Richter J, Thomsen E, Boisen A. Epoxy based photoresist/carbon nanoparticle composites Composites Science and Technology. 68: 1831-1836. DOI: 10.1016/J.Compscitech.2008.01.017  0.328
2007 Pinnaduwage LA, Gehl AC, Allman SL, Johansson A, Boisen A. Miniature sensor suitable for electronic nose applications. The Review of Scientific Instruments. 78: 055101. PMID 17552854 DOI: 10.1063/1.2735841  0.301
2007 Nordstrom M, Zauner DA, Boisen A, Hubner J. Single-Mode Waveguides With SU-8 Polymer Core and Cladding for MOEMS Applications Journal of Lightwave Technology. 25: 1284-1289. DOI: 10.1109/Jlt.2007.893902  0.322
2007 Nordström M, Calleja M, Hübner J, Boisen A. A novel fabrication technique for free-hanging homogeneous polymeric cantilever waveguides Journal of Micromechanics and Microengineering. 18: 015017. DOI: 10.1088/0960-1317/18/1/015017  0.309
2007 Nordström M, Zauner DA, Calleja M, Hübner J, Boisen A. Integrated optical readout for miniaturization of cantilever-based sensor system Applied Physics Letters. 91: 103512. DOI: 10.1063/1.2779851  0.34
2007 Davis ZJ, Svendsen W, Boisen A. Design, fabrication and testing of a novel MEMS resonator for mass sensing applications Microelectronic Engineering. 84: 1601-1605. DOI: 10.1016/J.Mee.2007.01.199  0.369
2006 Marie R, Schmid S, Johansson A, Ejsing L, Nordström M, Häfliger D, Christensen CB, Boisen A, Dufva M. Immobilisation of DNA to polymerised SU-8 photoresist. Biosensors & Bioelectronics. 21: 1327-32. PMID 16368483 DOI: 10.1016/J.Bios.2005.03.004  0.632
2006 Haefliger D, Boisen A. Three-dimensional microfabrication in negative resist using printed masks Journal of Micromechanics and Microengineering. 16: 951-957. DOI: 10.1088/0960-1317/16/5/011  0.334
2006 Johansson A, Janting J, Schultz P, Hoppe K, Hansen IN, Boisen A. SU-8 cantilever chip interconnection Journal of Micromechanics and Microengineering. 16: 314-319. DOI: 10.1088/0960-1317/16/2/016  0.305
2006 Johansson A, Hansen O, Hales J, Boisen A. Temperature effects in Au piezoresistors integrated in SU-8 cantilever chips Journal of Micromechanics and Microengineering. 16: 2564-2569. DOI: 10.1088/0960-1317/16/12/007  0.332
2006 Johansson A, Blagoi G, Boisen A. Polymeric cantilever-based biosensors with integrated readout Applied Physics Letters. 89. DOI: 10.1063/1.2364843  0.327
2006 Sadewasser S, Abadal G, Barniol N, Dohn S, Boisen A, Fonseca L, Estéve J. Integrated tunneling sensor for nanoelectromechanical systems Applied Physics Letters. 89: 173101. DOI: 10.1063/1.2362593  0.317
2006 Dohn S, Hansen O, Boisen A. Cantilever based mass sensor with hard contact readout Applied Physics Letters. 88: 264104. DOI: 10.1063/1.2217161  0.352
2006 Calleja M, Tamayo J, Nordström M, Boisen A. Low-noise polymeric nanomechanical biosensors Applied Physics Letters. 88: 113901. DOI: 10.1063/1.2187437  0.391
2006 Gammelgaard L, Rasmussen PA, Calleja M, Vettiger P, Boisen A. Microfabricated photoplastic cantilever with integrated photoplastic/carbon based piezoresistive strain sensor Applied Physics Letters. 88: 113508. DOI: 10.1063/1.2186396  0.318
2006 Villarroya M, Verd J, Teva J, Abadal G, Forsen E, Murano FP, Uranga A, Figueras E, Montserrat J, Esteve J, Boisen A, Barniol N. System on chip mass sensor based on polysilicon cantilevers arrays for multiple detection Sensors and Actuators a: Physical. 132: 154-164. DOI: 10.1016/J.Sna.2006.04.002  0.364
2005 Calleja M, Nordström M, Alvarez M, Tamayo J, Lechuga LM, Boisen A. Highly sensitive polymer-based cantilever-sensors for DNA detection. Ultramicroscopy. 105: 215-22. PMID 16051438 DOI: 10.1016/J.Ultramic.2005.06.039  0.391
2005 Verd J, Abadal G, Teva J, Gaudó MV, Uranga A, Borrisé X, Campabadal F, Esteve J, Figueras Costa E, Pérez-Murano F, Davis ZJ, Forsén E, Boisen A, Barniol N. Design, fabrication, and characterization of a submicroelectromechanical resonator with monolithically integrated CMOS readout circuit Journal of Microelectromechanical Systems. 14: 508-519. DOI: 10.1109/Jmems.2005.844845  0.369
2005 Sandberg R, Svendsen W, Mølhave K, Boisen A. Temperature and pressure dependence of resonance in multi-layer microcantilevers Journal of Micromechanics and Microengineering. 15: 1454-1458. DOI: 10.1088/0960-1317/15/8/011  0.337
2005 Rasmussen PA, Grigorov AV, Boisen A. Double sided surface stress cantilever sensor Journal of Micromechanics and Microengineering. 15: 1088-1091. DOI: 10.1088/0960-1317/15/5/027  0.314
2005 Sandberg R, Mølhave K, Boisen A, Svendsen W. Effect of gold coating on theQ-factor of a resonant cantilever Journal of Micromechanics and Microengineering. 15: 2249-2253. DOI: 10.1088/0960-1317/15/12/006  0.361
2005 Sandberg R, Boisen A, Svendsen W. Characterization system for resonant micro- and nanocantilevers Review of Scientific Instruments. 76: 125101. DOI: 10.1063/1.2140284  0.382
2005 Forsen E, Abadal G, Ghatnekar-Nilsson S, Teva J, Verd J, Sandberg R, Svendsen W, Perez-Murano F, Esteve J, Figueras E, Campabadal F, Montelius L, Barniol N, Boisen A. Ultrasensitive mass sensor fully integrated with complementary metal-oxide-semiconductor circuitry Applied Physics Letters. 87: 043507. DOI: 10.1063/1.1999838  0.37
2005 Davis ZJ, Boisen A. Aluminum nanocantilevers for high sensitivity mass sensors Applied Physics Letters. 87. DOI: 10.1063/1.1984092  0.35
2005 Dohn S, Sandberg R, Svendsen W, Boisen A. Enhanced functionality of cantilever based mass sensors using higher modes Applied Physics Letters. 86: 233501. DOI: 10.1063/1.1948521  0.32
2005 Rasmussen PA, Hansen O, Boisen A. Cantilever surface stress sensors with single-crystalline silicon piezoresistors Applied Physics Letters. 86: 203502. DOI: 10.1063/1.1900299  0.307
2005 Nordström M, Calleja M, Boisen A. Polymeric micro-channel-based functionalisation system for micro-cantilevers Ultramicroscopy. 105: 281-286. DOI: 10.1016/J.Ultramic.2005.06.053  0.305
2005 Mateiu R, Kühle A, Marie R, Boisen A. Building a multi-walled carbon nanotube-based mass sensor with the atomic force microscope Ultramicroscopy. 105: 233-237. DOI: 10.1016/J.Ultramic.2005.06.042  0.3
2005 Johansson A, Calleja M, Rasmussen PA, Boisen A. SU-8 cantilever sensor system with integrated readout Sensors and Actuators a-Physical. 123: 111-115. DOI: 10.1016/J.Sna.2005.03.025  0.347
2005 Grigorov AV, Boisen A. Novel resonant cantilever mass change detection and resonant frequency tuning Microelectronic Engineering. 78: 190-194. DOI: 10.1016/J.Mee.2004.12.026  0.359
2005 Haefliger D, Nordström M, Rasmussen PA, Boisen A. Dry release of all-polymer structures Microelectronic Engineering. 78: 88-92. DOI: 10.1016/J.Mee.2004.12.013  0.302
2004 Teva J, Abadal G, Davis ZJ, Verd J, Borrisé X, Boisen A, Pérez-Murano F, Barniol N. On the electromechanical modelling of a resonating nano-cantilever-based transducer. Ultramicroscopy. 100: 225-32. PMID 15231314 DOI: 10.1016/J.Ultramic.2003.12.013  0.311
2004 Ghatnekar-Nilsson S, Forsén E, Abadal G, Verd J, Campabadal F, Pérez-Murano F, Esteve J, Barniol N, Boisen A, Montelius L. Resonators with integrated CMOS circuitry for mass sensing applications, fabricated by electron beam lithography Nanotechnology. 16: 98-102. DOI: 10.1088/0957-4484/16/1/020  0.385
2004 Villarroya M, Pérez-Murano F, Martín C, Davis Z, Boisen A, Esteve J, Figueras E, Montserrat J, Barniol N. AFM lithography for the definition of nanometre scale gaps: Application to the fabrication of a cantilever-based sensor with electrochemical current detection Nanotechnology. 15: 771-776. DOI: 10.1088/0957-4484/15/7/009  0.339
2004 Forsén E, Nilsson SG, Carlberg P, Abadal G, Pérez-Murano F, Esteve J, Montserrat J, Figueras E, Campabadal F, Verd J, Montelius L, Barniol N, Boisen A. Fabrication of cantilever based mass sensors integrated with CMOS using direct write laser lithography on resist Nanotechnology. 15: S628-S633. DOI: 10.1088/0957-4484/15/10/021  0.325
2004 Grigorov AV, Davis ZJ, Rasmussen P, Boisen A. A longitudinal thermal actuation principle for mass detection using a resonant micro-cantilever in a fluid medium Microelectronic Engineering. 73: 881-886. DOI: 10.1016/J.Mee.2004.03.069  0.359
2003 Rasmussen PA, Thaysen J, Hansen O, Eriksen SC, Boisen A. Optimised cantilever biosensor with piezoresistive read-out. Ultramicroscopy. 97: 371-6. PMID 12801691 DOI: 10.1016/S0304-3991(03)00063-9  0.344
2003 Abadal G, Davis ZJ, Borrisé X, Hansen O, Boisen A, Barniol N, Pérez-Murano F, Serra F. Atomic force microscope characterization of a resonating nanocantilever. Ultramicroscopy. 97: 127-33. PMID 12801665 DOI: 10.1016/S0304-3991(03)00037-8  0.322
2003 Calleja M, Rasmussen PA, Johansson A, Boisen A. Polymeric mechanical sensors with piezoresistive readout integrated in a microfluidic system Proceedings of Spie. 5116: 314-321. DOI: 10.1117/12.498934  0.371
2003 Davis Z, Abadal G, Helbo B, Hansen O, Campabadal F, Pérez-Murano F, Esteve J, Figueras E, Verd J, Barniol N, Boisen A. Monolithic integration of mass sensing nano-cantilevers with CMOS circuitry Sensors and Actuators a: Physical. 105: 311-319. DOI: 10.1016/S0924-4247(03)00208-5  0.381
2002 Petersen CL, Hansen TM, Boggild P, Boisen A, Hansen O, Hassenkam T, Grey F. Scanning microscopic four-point conductivity probes Sensors and Actuators, a: Physical. 96: 53-58. DOI: 10.1016/S0924-4247(01)00765-8  0.332
2001 Abadal G, Davis ZJ, Helbo B, Borrisé X, Ruiz R, Boisen A, Campabadal F, Esteve J, Figueras E, Pérez-Murano F, Barniol N. Electromechanical model of a resonating nano-cantilever-based sensor for high-resolution and high-sensitivity mass detection Nanotechnology. 12: 100-104. DOI: 10.1088/0957-4484/12/2/305  0.357
2001 Rasmussen P, Thaysen J, Bouwstra S, Boisen A. Modular design of AFM probe with sputtered silicon tip Sensors and Actuators a: Physical. 92: 96-101. DOI: 10.1016/S0924-4247(01)00545-3  0.308
2000 Boisen A, Thaysen J, Jensenius H, Hansen O. Environmental sensors based on micromachined cantilevers with integrated read-out Ultramicroscopy. 82: 11-16. PMID 10741646 DOI: 10.1016/S0304-3991(99)00148-5  0.318
2000 Davis ZJ, Abadal G, Kuhn O, Hansen O, Grey F, Boisen A. Fabrication and characterization of nanoresonating devices for mass detection Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures. 18: 612. DOI: 10.1116/1.591247  0.385
2000 Jensenius H, Thaysen J, Rasmussen AA, Veje LH, Hansen O, Boisen A. A microcantilever-based alcohol vapor sensor-application and response model Applied Physics Letters. 76: 2615-2617. DOI: 10.1063/1.126426  0.305
2000 Thaysen J, Boisen A, Hansen O, Bouwstra S. Atomic force microscopy probe with piezoresistive read-out and a highly symmetrical Wheatstone bridge arrangement Sensors and Actuators a: Physical. 83: 47-53. DOI: 10.1016/S0924-4247(00)00299-5  0.33
1999 Andersen J, Zhang J, Chi Q, Hansen A, Nielsen J, Friis E, Ulstrup J, Boisen A, Jensenius H. In situ scanning probe microscopy and new perspectives in analytical chemistry Trac Trends in Analytical Chemistry. 18: 665-674. DOI: 10.1016/S0165-9936(99)00162-4  0.318
1996 Boisen A, Rasmussen J, Hansen O, Bouwstra S. Indirect tip fabrication for Scanning Probe Microscopy Microelectronic Engineering. 30: 579-582. DOI: 10.1016/0167-9317(95)00314-2  0.311
Show low-probability matches.