Year |
Citation |
Score |
2020 |
Shen X, Jiang J, Zhu H, Lu K, Dong P, Gu L. Comparative study of tapered versus conventional cylindrical balloon for stent implantation in stenotic tapered artery. Artificial Organs. PMID 32017159 DOI: 10.1111/Aor.13661 |
0.319 |
|
2019 |
Dong P, Mozafari H, Prabhu D, Bezerra HG, Wilson DL, Gu L. Oct-based Modeling of Stent Deployment in Heavily Calcified Coronary Lesion. Journal of Biomechanical Engineering. PMID 31654052 DOI: 10.1115/1.4045285 |
0.33 |
|
2019 |
Zheng Q, Dong P, Li Z, Han X, Zhou C, An M, Gu L. Mechanical characterizations of braided composite stents made of helical polyethylene terephthalate strips and NiTi wires Nanotechnology Reviews. 8: 168-174. DOI: 10.1515/Ntrev-2019-0016 |
0.322 |
|
2017 |
Hua Y, Wang Y, Gu L. Primary blast waves induced brain dynamics influenced by head orientations. Biomedical Engineering Letters. 7: 253-259. PMID 30603173 DOI: 10.1007/S13534-017-0027-2 |
0.347 |
|
2017 |
Lin S, Han X, Bi Y, Ju S, Gu L. Fluid-Structure Interaction in Abdominal Aortic Aneurysm: Effect of Modeling Techniques. Biomed Research International. 2017: 7023078. PMID 28321413 DOI: 10.1155/2017/7023078 |
0.323 |
|
2015 |
Hua Y, Lin S, Gu L. Relevance of Blood Vessel Networks in Blast-Induced Traumatic Brain Injury. Computational and Mathematical Methods in Medicine. 2015: 928236. PMID 26495036 DOI: 10.1155/2015/928236 |
0.309 |
|
2015 |
Hua Y, Akula P, Kelso M, Gu L. Characterization of Closed Head Impact Injury in Rat. Biomed Research International. 2015: 272976. PMID 26451365 DOI: 10.1155/2015/272976 |
0.332 |
|
2015 |
Akula P, Hua Y, Gu L. Blast-induced mild traumatic brain injury through ear canal: A finite element study Biomedical Engineering Letters. 5: 281-288. DOI: 10.1007/S13534-015-0204-0 |
0.32 |
|
2014 |
Zhao S, Gu L. Implementation and validation of aortic remodeling in hypertensive rats. Journal of Biomechanical Engineering. 136: 091007. PMID 24976411 DOI: 10.1115/1.4027939 |
0.323 |
|
2014 |
Hua Y, Akula PK, Gu L, Berg J, Nelson CA. Experimental and numerical investigation of the mechanism of blast wave transmission through a surrogate head Journal of Computational and Nonlinear Dynamics. 9. DOI: 10.1115/1.4026156 |
0.343 |
|
2014 |
Hua Y, Akula PK, Gu L. Experimental and numerical investigation of carbon fiber sandwich panels subjected to blast loading Composites Part B-Engineering. 56: 456-463. DOI: 10.1016/J.Compositesb.2013.08.070 |
0.331 |
|
2013 |
Zhao S, Gu L, Froemming SR. Experimental investigation of the stent-artery interaction. Journal of Medical Engineering & Technology. 37: 463-9. PMID 24044587 DOI: 10.3109/03091902.2013.831491 |
0.322 |
|
2012 |
Zhao S, Gu L, Froemming SR. Performance of self-expanding nitinol stent in a curved artery: impact of stent length and deployment orientation. Journal of Biomechanical Engineering. 134. PMID 24763629 DOI: 10.1115/1.4007095 |
0.325 |
|
2012 |
Zhao S, Gu L, Froemming SR. On the importance of modeling stent procedure for predicting arterial mechanics. Journal of Biomechanical Engineering. 134: 121005. PMID 23363207 DOI: 10.1115/1.4023094 |
0.335 |
|
2012 |
Steinert BD, Zhao S, Gu L. Monitoring the wall mechanics during stent deployment in a vessel. Journal of Visualized Experiments : Jove. e3945. PMID 22588353 DOI: 10.3791/3945 |
0.312 |
|
2012 |
Ganpule S, Gu L, Alai A, Chandra N. Role of helmet in the mechanics of shock wave propagation under blast loading conditions. Computer Methods in Biomechanics and Biomedical Engineering. 15: 1233-44. PMID 21806412 DOI: 10.1080/10255842.2011.597353 |
0.685 |
|
2012 |
Gu L, Zhao S, Froemming SR. Arterial Wall Mechanics And Clinical Implications After Coronary Stenting: Comparisons Of Three Stent Designs International Journal of Applied Mechanics. 4: 1250013. DOI: 10.1142/S1758825112500135 |
0.327 |
|
2012 |
Zhao S, Liu XC, Gu L. The Impact of Wire Stent Fabrication Technique on the Performance of Stent Placement Journal of Medical Devices-Transactions of the Asme. 6: 11007. DOI: 10.1115/1.4005788 |
0.309 |
|
2012 |
Gu L, Chafi MS, Ganpule S, Chandra N. The influence of heterogeneous meninges on the brain mechanics under primary blast loading Composites Part B-Engineering. 43: 3160-3166. DOI: 10.1016/J.Compositesb.2012.04.014 |
0.719 |
|
2012 |
Zhao S, Gu L, Froemming SR. Effects of arterial strain and stress in the prediction of restenosis risk: Computer modeling of stent trials Biomedical Engineering Letters. 2: 158-163. DOI: 10.1007/S13534-012-0067-6 |
0.325 |
|
2011 |
Chafi MS, Ganpule SG, Gu L, Chandra N. Dynamic Response Of Brain Subjected To Blast Loadings: Influence Of Frequency Ranges International Journal of Applied Mechanics. 3: 803-823. DOI: 10.1142/S175882511100124X |
0.706 |
|
2010 |
Gu L, Zhao S, Muttyam AK, Hammel JM. The Relation Between the Arterial Stress and Restenosis Rate After Coronary Stenting Journal of Medical Devices-Transactions of the Asme. 4: 31005. DOI: 10.1115/1.4002238 |
0.334 |
|
2008 |
Muttyam AK, Gu L. The Effect of Stent Design on the Restenosis Rate Journal of Medical Devices-Transactions of the Asme. 2: 27526. DOI: 10.1115/1.2934540 |
0.331 |
|
2007 |
Gu L, Santra S, Kumar AV. Biomechanics of stent grafts for intracranial aneurysm repair Proceedings of the 2nd Frontiers in Biomedical Devices Conference 2007. 31-32. DOI: 10.1115/Biomed2007-38025 |
0.303 |
|
2005 |
Gu L, Santra S, Mericle RA, Kumar AV. Finite element analysis of covered microstents. Journal of Biomechanics. 38: 1221-7. PMID 15863106 DOI: 10.1016/J.Jbiomech.2004.06.008 |
0.345 |
|
Show low-probability matches. |