Year |
Citation |
Score |
2022 |
Ren L, Woodrum DA, Gorny KR, Felmlee JP, Favazza CP, Thompson SM, Lu A. Dual-applicator MRI-guided microwave ablation with real-time MR thermometry: phantom/porcine tissue model experiments. Journal of Vascular and Interventional Radiology : Jvir. PMID 36202337 DOI: 10.1016/j.jvir.2022.09.024 |
0.332 |
|
2020 |
Lu A, Woodrum DA, Felmlee JP, Favazza CP, Gorny KR. Improved MR-thermometry during hepatic microwave ablation by correcting for intermittent electromagnetic interference artifacts. Physica Medica : Pm : An International Journal Devoted to the Applications of Physics to Medicine and Biology : Official Journal of the Italian Association of Biomedical Physics (Aifb). 71: 100-107. PMID 32114323 DOI: 10.1016/J.Ejmp.2020.02.013 |
0.315 |
|
2019 |
Lu A, Atkinson IC, Thulborn KR. Motion reduction for quantitative brain sodium MR imaging with a navigated flexible twisted projection imaging sequence at 9.4 T. Journal of Magnetic Resonance (San Diego, Calif. : 1997). 307: 106582. PMID 31499470 DOI: 10.1016/j.jmr.2019.106582 |
0.45 |
|
2013 |
Lu A, Atkinson IC, Zhou XJ, Thulborn KR. PCr/ATP ratio mapping of the human head by simultaneously imaging of multiple spectral peaks with interleaved excitations and flexible twisted projection imaging readout trajectories at 9.4 T. Magnetic Resonance in Medicine. 69: 538-44. PMID 22529019 DOI: 10.1002/Mrm.24281 |
0.416 |
|
2012 |
Atkinson IC, Lu A, Thulborn KR. Preserving the accuracy and resolution of the sodium bioscale from quantitative sodium MRI during intrasubject alignment across longitudinal studies. Magnetic Resonance in Medicine. 68: 751-61. PMID 22139900 DOI: 10.1002/mrm.23285 |
0.358 |
|
2011 |
Atkinson IC, Lu A, Thulborn KR. Clinically constrained optimization of flexTPI acquisition parameters for the tissue sodium concentration bioscale. Magnetic Resonance in Medicine. 66: 1089-99. PMID 21446034 DOI: 10.1002/mrm.22908 |
0.42 |
|
2010 |
Lu A, Atkinson IC, Claiborne TC, Damen FC, Thulborn KR. Quantitative sodium imaging with a flexible twisted projection pulse sequence. Magnetic Resonance in Medicine. 63: 1583-93. PMID 20512862 DOI: 10.1002/Mrm.22381 |
0.447 |
|
2009 |
Jung Y, Samsonov AA, Block WF, Lazar M, Lu A, Liu J, Alexander AL. 3D diffusion tensor MRI with isotropic resolution using a steady-state radial acquisition. Journal of Magnetic Resonance Imaging : Jmri. 29: 1175-84. PMID 19388107 DOI: 10.1002/Jmri.21663 |
0.672 |
|
2009 |
Atkinson IC, Lu A, Thulborn KR. Characterization and correction of system delays and eddy currents for MR imaging with ultrashort echo-time and time-varying gradients. Magnetic Resonance in Medicine. 62: 532-7. PMID 19353662 DOI: 10.1002/mrm.22016 |
0.371 |
|
2008 |
Lu A, Daniel BL, Pauly JM, Pauly KB. Improved slice selection for R2* mapping during cryoablation with eddy current compensation. Journal of Magnetic Resonance Imaging : Jmri. 28: 190-8. PMID 18581340 DOI: 10.1002/Jmri.21396 |
0.393 |
|
2006 |
Kijowski R, Lu A, Block W, Grist T. Evaluation of the articular cartilage of the knee joint with vastly undersampled isotropic projection reconstruction steady-state free precession imaging. Journal of Magnetic Resonance Imaging : Jmri. 24: 168-75. PMID 16758476 DOI: 10.1002/Jmri.20596 |
0.598 |
|
2006 |
Liu J, Redmond MJ, Brodsky EK, Alexander AL, Lu A, Thornton FJ, Schulte MJ, Grist TM, Pipe JG, Block WF. Generation and visualization of four-dimensional MR angiography data using an undersampled 3-D projection trajectory. Ieee Transactions On Medical Imaging. 25: 148-57. PMID 16468449 DOI: 10.1109/Tmi.2005.861706 |
0.689 |
|
2005 |
Lu A, Grist TM, Block WF. Fat/water separation in single acquisition steady-state free precession using multiple echo radial trajectories. Magnetic Resonance in Medicine. 54: 1051-7. PMID 16217786 DOI: 10.1002/Mrm.20715 |
0.628 |
|
2005 |
Lu A, Brodsky E, Grist TM, Block WF. Rapid fat-suppressed isotropic steady-state free precession imaging using true 3D multiple-half-echo projection reconstruction. Magnetic Resonance in Medicine. 53: 692-9. PMID 15723411 DOI: 10.1002/Mrm.20389 |
0.714 |
|
2005 |
Du J, Lu A, Block WF, Thornton FJ, Grist TM, Mistretta CA. Time-resolved undersampled projection reconstruction magnetic resonance imaging of the peripheral vessels using multi-echo acquisition. Magnetic Resonance in Medicine. 53: 730-4. PMID 15723388 DOI: 10.1002/Mrm.20404 |
0.695 |
|
2004 |
Du J, Carroll TJ, Brodsky E, Lu A, Grist TM, Mistretta CA, Block WF. Contrast-enhanced peripheral magnetic resonance angiography using time-resolved vastly undersampled isotropic projection reconstruction. Journal of Magnetic Resonance Imaging : Jmri. 20: 894-900. PMID 15503332 DOI: 10.1002/Jmri.20189 |
0.701 |
|
2004 |
Lu A, Barger AV, Grist TM, Block WF. Improved spectral selectivity and reduced susceptibility in SSFP using a near zero TE undersampled three-dimensional PR sequence. Journal of Magnetic Resonance Imaging : Jmri. 19: 117-23. PMID 14696228 DOI: 10.1002/Jmri.10435 |
0.677 |
|
Show low-probability matches. |