Year |
Citation |
Score |
2020 |
Ebert CH, Saetveit NJ, Bajic SJ, Zamzow DS, Baldwin DP, Houk RS. High-speed photographic study of vaporclouds from wet droplets and the subsequent solid particles in an inductively coupled plasma Journal of Analytical Atomic Spectrometry. 35: 1956-1958. DOI: 10.1039/D0Ja00210K |
0.757 |
|
2020 |
Thompson J, Houk R, Olin P, Fryer F, Danyushevsky L. The effects of H2O, He, N2 and H2 on ion kinetic energies in inductively coupled plasma mass spectrometry Spectrochimica Acta Part B: Atomic Spectroscopy. 169: 105870. DOI: 10.1016/J.Sab.2020.105870 |
0.46 |
|
2019 |
McVey PA, Webster GK, Galayda KJ, Houk RS. Rapid diagnosis of drug agglomeration and crystallinity in pharmaceutical preparations by electrospray laser desorption ionization mass spectrometry imaging. Journal of Pharmaceutical and Biomedical Analysis. 112977. PMID 31810822 DOI: 10.1016/J.Jpba.2019.112977 |
0.324 |
|
2018 |
McVey PA, Alexander LE, Fu X, Xie B, Galayda KJ, Nikolau BJ, Houk RS. Light-Dependent Changes in the Spatial Localization of Metabolites in (Coleus Henna) Visualized by Matrix-Free Atmospheric Pressure Electrospray Laser Desorption Ionization Mass Spectrometry Imaging. Frontiers in Plant Science. 9: 1348. PMID 30283472 DOI: 10.3389/Fpls.2018.01348 |
0.33 |
|
2016 |
Hattendorf B, Gusmini B, Dorta L, Houk RS, Günther D. Abundance and Impact of Doubly Charged Polyatomic Argon Interferences in ICPMS Spectra. Analytical Chemistry. PMID 27306032 DOI: 10.1021/Acs.Analchem.6B01614 |
0.433 |
|
2016 |
Hattendorf B, Gusmini B, Dorta L, Houk RS, Günther D. Mass spectrometric observation of doubly charged alkaline earth argon ions. Chemphyschem : a European Journal of Chemical Physics and Physical Chemistry. PMID 27252087 DOI: 10.1002/Cphc.201600441 |
0.439 |
|
2013 |
Lindemann WR, Xiao T, Wang W, Berry JE, Anderson NA, Houk RS, Shinar R, Shinar J, Vaknin D. An X-ray fluorescence study on the segregation of Cs and i in an inverted organic solar cell Organic Electronics: Physics, Materials, Applications. 14: 3190-3194. DOI: 10.1016/J.Orgel.2013.09.019 |
0.301 |
|
2012 |
Ebert CH, Witte TM, Houk RS. Investigation into the behavior of metal-argon polyatomic ions (MAr +) in the extraction region of inductively coupled plasma-mass spectrometry Spectrochimica Acta - Part B Atomic Spectroscopy. 76: 119-125. DOI: 10.1016/J.Sab.2012.06.046 |
0.803 |
|
2012 |
Witte TM, Houk RS. Metal argide (MAr +) ions are lost during ion extraction in laser ablation-inductively coupled plasma-mass spectrometry Spectrochimica Acta - Part B Atomic Spectroscopy. 69: 25-31. DOI: 10.1016/J.Sab.2012.02.008 |
0.829 |
|
2012 |
Witte TM, Houk RS. Origins of polyatomic ions in laser ablation-inductively coupled plasma-mass spectrometry: An examination of metal oxide ions and effects of nitrogen and helium in the aerosol gas flow Spectrochimica Acta - Part B Atomic Spectroscopy. 69: 9-19. DOI: 10.1016/J.Sab.2012.02.005 |
0.829 |
|
2011 |
Martin DP, Anantharam V, Jin H, Witte T, Houk R, Kanthasamy A, Kanthasamy AG. Infectious prion protein alters manganese transport and neurotoxicity in a cell culture model of prion disease. Neurotoxicology. 32: 554-62. PMID 21871919 DOI: 10.1016/J.Neuro.2011.07.008 |
0.768 |
|
2011 |
McIntyre SM, Ferguson JW, Houk RS. Determination of dissociation temperature for ArO+ in inductively coupled plasma-mass spectrometry: Effects of excited electronic states and dissociation pathways Spectrochimica Acta - Part B Atomic Spectroscopy. 66: 581-587. DOI: 10.1016/J.Sab.2011.06.002 |
0.379 |
|
2011 |
McIntyre SM, Ferguson JW, Witte TM, Houk RS. Measurement of gas kinetic temperatures for polyatomic ions in inductively coupled plasma-mass spectrometry: Validation and refinements Spectrochimica Acta - Part B Atomic Spectroscopy. 66: 248-254. DOI: 10.1016/J.Sab.2011.02.003 |
0.795 |
|
2010 |
Rockafellow EM, Haywood JM, Witte T, Houk RS, Jenks WS. Selenium-modified TiO2 and its impact on photocatalysis. Langmuir : the Acs Journal of Surfaces and Colloids. 26: 19052-9. PMID 21073164 DOI: 10.1021/La1026569 |
0.742 |
|
2010 |
Zhao Q, Schieffer GM, Soyk MW, Anderson TJ, Houk RS, Badman ER. Effects of ion/ion proton transfer reactions on conformation of gas-phase cytochrome c ions. Journal of the American Society For Mass Spectrometry. 21: 1208-17. PMID 20430642 DOI: 10.1016/J.Jasms.2010.03.032 |
0.784 |
|
2010 |
Perdian DC, Schieffer GM, Houk RS. Atmospheric pressure laser desorption/ionization of plant metabolites and plant tissue using colloidal graphite. Rapid Communications in Mass Spectrometry : Rcm. 24: 397-402. PMID 20069689 DOI: 10.1002/rcm.4405 |
0.782 |
|
2009 |
Afeseh Ngwa H, Kanthasamy A, Anantharam V, Song C, Witte T, Houk R, Kanthasamy AG. Vanadium induces dopaminergic neurotoxicity via protein kinase Cdelta dependent oxidative signaling mechanisms: relevance to etiopathogenesis of Parkinson's disease. Toxicology and Applied Pharmacology. 240: 273-85. PMID 19646462 DOI: 10.1016/J.Taap.2009.07.025 |
0.762 |
|
2009 |
Gross CT, McIntyre SM, Houk RS. Reduction of matrix effects in inductively coupled plasma mass spectrometry by flow injection with an unshielded torch. Analytical Chemistry. 81: 4898-905. PMID 19518145 DOI: 10.1021/ac900568x |
0.73 |
|
2009 |
Zhao Q, Soyk MW, Schieffer GM, Fuhrer K, Gonin MM, Houk RS, Badman ER. An ion trap-ion mobility-time of flight mass spectrometer with three ion sources for ion/ion reactions. Journal of the American Society For Mass Spectrometry. 20: 1549-61. PMID 19493684 DOI: 10.1016/J.Jasms.2009.04.014 |
0.79 |
|
2008 |
Soyk MW, Zhao Q, Houk RS, Badman ER. A linear ion trap mass spectrometer with versatile control and data acquisition for ion/ion reactions. Journal of the American Society For Mass Spectrometry. 19: 1821-31. PMID 18838277 DOI: 10.1016/J.Jasms.2008.08.020 |
0.788 |
|
2008 |
Sears KC, Ferguson JW, Dudley TJ, Houk RS, Gordon MS. Theoretical investigation of small polyatomic ions observed in inductively coupled plasma mass spectrometry: H(x)CO+ and H(x)N2(+) (x = 1, 2, 3). The Journal of Physical Chemistry. A. 112: 2610-7. PMID 18311946 DOI: 10.1021/Jp077209K |
0.32 |
|
2008 |
Perdian DC, Bajic SJ, Baldwin DP, Houk RS. Time-resolved studies of particle effects in laser ablation inductively coupled plasma-mass spectrometry: Part 2. Investigation of MO+ ions, effect of sample morphology, transport gas, and binding agents Journal of Analytical Atomic Spectrometry. 23: 336-341. DOI: 10.1039/B710075B |
0.819 |
|
2008 |
Perdian DC, Bajic SJ, Baldwin DP, Houk RS. Time-resolved studies of particle effects in laser ablation inductively coupled plasma-mass spectrometry: Part 1. Investigation of nanosecond and femtosecond pulse width lasers and devices for particle size selection Journal of Analytical Atomic Spectrometry. 23: 325-335. DOI: 10.1039/B710074D |
0.787 |
|
2008 |
Saetveit NJ, Bajic SJ, Baldwin DP, Houk RS. Influence of particle size on fractionation with nanosecond and femtosecond laser ablation in brass by online differential mobility analysis and inductively coupled plasma mass spectrometry Journal of Analytical Atomic Spectrometry. 23: 54-61. DOI: 10.1039/B709995A |
0.787 |
|
2007 |
Choi CJ, Anantharam V, Saetveit NJ, Houk RS, Kanthasamy A, Kanthasamy AG. Normal cellular prion protein protects against manganese-induced oxidative stress and apoptotic cell death. Toxicological Sciences : An Official Journal of the Society of Toxicology. 98: 495-509. PMID 17483122 DOI: 10.1093/Toxsci/Kfm099 |
0.753 |
|
2007 |
Ryu W, Kim D, Lim HB, Houk RS. Polymer (Polydimethylsiloxane (pdms)) Microchip Plasma with Electrothermal Vaporization for the Determination of Metal Ions in Aqueous Solution Bulletin of the Korean Chemical Society. 28: 553-556. DOI: 10.5012/Bkcs.2007.28.4.553 |
0.392 |
|
2007 |
Spry PG, Heimann A, Messerly JD, Houk RS. Discrimination of metamorphic and metasomatic processes at the Broken Hill Pb-Zn-Ag deposit, Australia: Earth element signatures of garnet-rich rocks Economic Geology. 102: 471-494. DOI: 10.2113/Gsecongeo.102.3.471 |
0.739 |
|
2007 |
Lentz NB, Houk RS. Negative ion mode electrospray ionization mass spectrometry study of ammonium-counter ion clusters Journal of the American Society For Mass Spectrometry. 18: 285-293. DOI: 10.1016/J.Jasms.2006.09.028 |
0.383 |
|
2006 |
Ferguson JW, Houk RS. High resolution studies of the origins of polyatomic ions in inductively coupled plasma-mass spectrometry, Part I. Identification methods and effects of neutral gas density assumptions, extraction voltage, and cone material Spectrochimica Acta - Part B Atomic Spectroscopy. 61: 905-915. DOI: 10.1016/J.Sab.2006.07.001 |
0.471 |
|
2006 |
Houk R. Erratum to “Dissociation of polyatomic ions in inductively coupled plasma-mass spectrometry” [Spectrochimica Acta Part B 56 (2001) 1069–1096] Spectrochimica Acta Part B: Atomic Spectroscopy. 61: 235-236. DOI: 10.1016/j.sab.2006.01.006 |
0.33 |
|
2005 |
Bajic SJ, Aeschliman DB, Saetveit NJ, Baldwin DP, Houk RS. Analysis of glass fragments by laser ablation-inductively coupled plasma-mass spectrometry and principal component analysis. Journal of Forensic Sciences. 50: 1123-7. PMID 16225219 DOI: 10.1520/Jfs2005088 |
0.776 |
|
2005 |
Mukherjee S, Rodrigues E, Aeschliman DB, Houk RS, Palmer LJ, Woodin MA, Weker R, Christiani DC. Urinary metal and polycyclic aromatic hydrocarbon biomarkers in boilermakers exposed to metal fume and residual oil fly ash. American Journal of Industrial Medicine. 47: 484-93. PMID 15898092 DOI: 10.1002/Ajim.20161 |
0.76 |
|
2005 |
Li F, Armstrong DW, Houk RS. Behavior of bacteria in the inductively coupled plasma: atomization and production of atomic ions for mass spectrometry. Analytical Chemistry. 77: 1407-13. PMID 15732925 DOI: 10.1021/Ac049188L |
0.593 |
|
2005 |
Lim H, Kim D, Jung T, Houk R, Kim Y. A radiofrequency plasma in a polydimethylsiloxane (PDMS) microchip Analytica Chimica Acta. 545: 119-121. DOI: 10.1016/J.Aca.2005.04.067 |
0.328 |
|
2005 |
Hasan T, Gazda D, Porter MD, Houk RS. On-line cleanup of blanks by electrochemically modulated liquid chromatography for inductively coupled plasma-mass spectrometry Analytica Chimica Acta. 537: 63-68. DOI: 10.1016/J.Aca.2004.12.081 |
0.414 |
|
2004 |
Li F, Houk RS. Controlled dissolution for elemental analysis of sample layers by inductively coupled plasma-mass spectrometry: a feasibility study. Applied Spectroscopy. 58: 776-83. PMID 15282041 DOI: 10.1366/0003702041389256 |
0.594 |
|
2004 |
Aeschliman DB, Bajic SJ, Baldwin DP, Houk RS. Multivariate pattern matching of trace elements in solids by laser ablation inductively coupled plasma-mass spectrometry: source attribution and preliminary diagnosis of fractionation. Analytical Chemistry. 76: 3119-25. PMID 15167791 DOI: 10.1021/Ac0345042 |
0.81 |
|
2004 |
Mukherjee S, Palmer LJ, Kim JY, Aeschliman DB, Houk RS, Woodin MA, Christiani DC. Smoking status and occupational exposure affects oxidative DNA injury in boilermakers exposed to metal fume and residual oil fly ash. Cancer Epidemiology, Biomarkers & Prevention : a Publication of the American Association For Cancer Research, Cosponsored by the American Society of Preventive Oncology. 13: 454-60. PMID 15006923 |
0.764 |
|
2003 |
Zhang B, Li F, Houk RS, Armstrong DW. Pore exclusion chromatography-inductively coupled plasma-mass spectrometry for monitoring elements in bacteria: a study on microbial removal of uranium from aqueous solution. Analytical Chemistry. 75: 6901-5. PMID 14670051 DOI: 10.1021/Ac0348017 |
0.588 |
|
2003 |
Kim JY, Hauser R, Wand MP, Herrick RF, Houk RS, Aeschliman DB, Woodin MA, Christiani DC. Association of expired nitric oxide with urinary metal concentrations in boilermakers exposed to residual oil fly ash. American Journal of Industrial Medicine. 44: 458-66. PMID 14571509 DOI: 10.1002/Ajim.10305 |
0.764 |
|
2003 |
Li F, Byers MA, Houk RS. Tandem mass spectrometry of metal nitrate negative ions produced by electrospray ionization. Journal of the American Society For Mass Spectrometry. 14: 671-9. PMID 12781468 DOI: 10.1016/S1044-0305(03)00210-1 |
0.62 |
|
2003 |
Luong ET, Houk RS. Determination of carbon isotope ratios in amino acids, proteins, and oligosaccharides by inductively coupled plasma-mass spectrometry. Journal of the American Society For Mass Spectrometry. 14: 295-301. PMID 12686476 DOI: 10.1016/S1044-0305(03)00003-5 |
0.365 |
|
2003 |
Aeschliman DB, Bajic SJ, Baldwin DP, Houk RS. High-speed digital photographic study of an inductively coupled plasma during laser ablation: Comparison of dried solution aerosols from a microconcentric nebulizer and solid particles from laser ablation Journal of Analytical Atomic Spectrometry. 18: 1008-1014. DOI: 10.1039/B302546M |
0.8 |
|
2003 |
Aeschliman DB, Bajic SJ, Baldwin DP, Houk RS. Spatially-resolved analysis of solids by laser ablation-inductively coupled plasma-mass spectrometry: Trace elemental quantification without matrix-matched solid standards Journal of Analytical Atomic Spectrometry. 18: 872-877. DOI: 10.1039/B205683F |
0.815 |
|
2001 |
Wang J, Dreessen D, Wiederin DR, Houk RS. Measurement of trace elements in proteins extracted from liver by size exclusion chromatography-inductively coupled plasma-mass spectrometry with a magnetic sector mass spectrometer. Analytical Biochemistry. 288: 89-96. PMID 11141310 DOI: 10.1006/Abio.2000.4885 |
0.362 |
|
2001 |
Houk R, Praphairaksit N. Dissociation of polyatomic ions in the inductively coupled plasma Spectrochimica Acta Part B: Atomic Spectroscopy. 56: 1069-1096. DOI: 10.1016/S0584-8547(01)00236-1 |
0.325 |
|
2001 |
Houk RS, Zhai Y. Comparison of mass spectrometric and optical measurements of temperature and electron density in the inductively coupled plasma during mass spectrometric sampling Spectrochimica Acta - Part B Atomic Spectroscopy. 56: 1055-1067. DOI: 10.1016/S0584-8547(01)00202-6 |
0.305 |
|
2001 |
Hasan T, Praphairaksit N, Houk R. Low flow, externally air cooled torch for inductively coupled plasma atomic emission spectrometry with axial viewing Spectrochimica Acta Part B: Atomic Spectroscopy. 56: 409-418. DOI: 10.1016/S0584-8547(01)00168-9 |
0.328 |
|
2000 |
Praphairaksit N, Houk RS. Reduction of mass bias and matrix effects in inductively coupled plasma mass spectrometry with a supplemental electron source in a negative extraction lens Analytical Chemistry. 72: 4435-40. PMID 11008780 |
0.321 |
|
2000 |
Praphairaksit N, Houk RS. Reduction of space charge effects in inductively coupled plasma mass spectrometry using a supplemental electron source inside the skimmer: ion transmission and mass spectral characteristics Analytical Chemistry. 72: 2356-61. PMID 10857605 |
0.327 |
|
2000 |
Amad MH, Houk RS. Mass resolution of 11,000 to 22,000 with a multiple pass quadrupole mass analyzer Journal of the American Society For Mass Spectrometry. 11: 407-15. PMID 10790844 |
0.323 |
|
2000 |
Mollah S, Pris AD, Johnson SK, Gwizdala AB, Houk RS. Identification of metal cations, metal complexes, and anions by electrospray mass spectrometry in the negative ion mode Analytical Chemistry. 72: 985-91. PMID 10739202 DOI: 10.1021/Ac9908647 |
0.392 |
|
2000 |
Du Z, Houk RS. Attenuation of metal oxide ions in inductively coupled plasma mass spectrometry with hydrogen in a hexapole collision cell Journal of Analytical Atomic Spectrometry. 15: 383-388. DOI: 10.1039/A905046I |
0.429 |
|
2000 |
Praphairaksit N, Wiederin DR, Houk R. An externally air-cooled low-flow torch for inductively coupled plasma mass spectrometry Spectrochimica Acta Part B: Atomic Spectroscopy. 55: 1279-1293. DOI: 10.1016/S0584-8547(00)00216-0 |
0.346 |
|
1999 |
Wang J, Houk RS, Dreessen D, Wiederin DR. Speciation of trace elements in proteins in human and bovine serum by size exclusion chromatography and inductively coupled plasma-mass spectrometry with a magnetic sector mass spectrometer. Journal of Biological Inorganic Chemistry : Jbic : a Publication of the Society of Biological Inorganic Chemistry. 4: 546-53. PMID 10550683 DOI: 10.1007/S007750050377 |
0.441 |
|
1999 |
Johnson SK, Houk LL, Feng J, Houk RS, Johnson DC. Electrochemical Incineration of 4-Chlorophenol and the Identification of Products and Intermediates by Mass Spectrometry Environmental Science & Technology. 33: 2638-2644. DOI: 10.1021/Es981045R |
0.362 |
|
1999 |
Leach JJ, Allen LA, Aeschliman DB, Houk RS. Calibration of laser ablation inductively coupled plasma mass spectrometry using standard additions with dried solution aerosols Analytical Chemistry. 71: 440-445. DOI: 10.1021/Ac980855I |
0.804 |
|
1999 |
Johnson SK, Houk LL, Johnson DC, Houk R. Determination of small carboxylic acids by capillary electrophoresis with electrospray-mass spectrometry Analytica Chimica Acta. 389: 1-8. DOI: 10.1016/S0003-2670(99)00122-1 |
0.361 |
|
1998 |
Espenson JH, Tan H, Mollah S, Houk RS, Eager MD. Base Hydrolysis of Methyltrioxorhenium. The Mechanism Revised and Extended: A Novel Application of Electrospray Mass Spectrometry. Inorganic Chemistry. 37: 4621-4624. PMID 11670611 DOI: 10.1021/Ic980447X |
0.313 |
|
1998 |
Minnich MG, Houk RS. Comparison of cryogenic and membrane desolvation for attenuation of oxide, hydride and hydroxide ions and ions containing chlorine in inductively coupled plasma mass spectrometry Journal of Analytical Atomic Spectrometry. 13: 167-174. DOI: 10.1039/A704274D |
0.341 |
|
1998 |
Minnich MG, Houk RS. Comparison of cryogenic and membrane desolvation for attenuation of oxide, hydride and hydroxide ions and ions containing chlorine in inductively coupled plasma mass spectrometry Journal of Analytical Atomic Spectrometry. 13: 167-174. DOI: 10.1039/A704274D |
0.36 |
|
1998 |
Houk LL, Johnson SK, Feng J, Houk RS, Johnson DC. Journal of Applied Electrochemistry. 28: 1167-1177. DOI: 10.1023/A:1003439727317 |
0.324 |
|
1998 |
Wang J, Houk RS, Dreessen D, Wiederin DR. Identification of Inorganic Elements in Proteins in Human Serum and in DNA Fragments by Size Exclusion Chromatography and Inductively Coupled Plasma Mass Spectrometry with a Magnetic Sector Mass Spectrometer Journal of the American Chemical Society. 120: 5793-5799. DOI: 10.1021/Ja9735970 |
0.315 |
|
1998 |
Houk R. Electrospray and ICP-mass spectrometry: enemies or allies? Spectrochimica Acta Part B: Atomic Spectroscopy. 53: 267-271. DOI: 10.1016/S0584-8547(97)00147-X |
0.416 |
|
1997 |
Allen LA, Leach JJ, Houk RS. Spatial location of the space charge effect in individual ion clouds using monodisperse dried microparticulate injection with a twin quadrupole inductively coupled plasma mass spectrometer. Analytical Chemistry. 69: 2384-91. PMID 21639373 DOI: 10.1021/Ac9610624 |
0.467 |
|
1997 |
Minnich MG, Houk RS, Woodin MA, Christiani DC. Method to screen urine samples for vanadium by inductively coupled plasma mass spectrometry with cryogenic desolvation Journal of Analytical Atomic Spectrometry. 12: 1345-1350. DOI: 10.1039/A700172J |
0.424 |
|
1997 |
LUONG ET, HOUK RS, SERFASS RE. Chromatographic Isolation of Molybdenum From Human Blood Plasma and Determination by Inductively Coupled Plasma Mass Spectrometry With Isotope Dilution Journal of Analytical Atomic Spectrometry. 12: 703-708. DOI: 10.1039/A608265C |
0.349 |
|
1997 |
Houk RS, Winge RK, Chen X. High Speed Photographic Study of Wet Droplets and Solid Particles in the Inductively Coupled Plasma Journal of Analytical Atomic Spectrometry. 12: 1139-1148. DOI: 10.1039/A607579G |
0.363 |
|
1997 |
ALLEN LA, LEACH JJ, PANG H, HOUK RS. Precise Measurement of Ion Ratios in Solid Samples Using Laser Ablation With a Twin Quadrupole Inductively Coupled Plasma Mass Spectrometer Journal of Analytical Atomic Spectrometry. 12: 171-176. DOI: 10.1039/A603310E |
0.395 |
|
1997 |
Johnson SK, Houk LL, Feng J, Johnson DC, Houk R. Determination of small carboxylic acids by ion exclusion chromatography with electrospray mass spectrometry Analytica Chimica Acta. 341: 205-216. DOI: 10.1016/S0003-2670(96)00572-7 |
0.435 |
|
1996 |
Hu K, Houk RS. Ion deposition by inductively coupled plasma mass spectrometry Journal of Vacuum Science & Technology a: Vacuum, Surfaces, and Films. 14: 370-373. DOI: 10.1116/1.579903 |
0.362 |
|
1996 |
Luan S, Pang H, Houk RS. Optical emission studies of the Mach disc extracted from an inductively coupled plasma with an échelle spectrometer and segmented-array charge-coupled detectors J. Anal. At. Spectrom.. 11: 247-252. DOI: 10.1039/Ja9961100247 |
0.35 |
|
1996 |
Niu H, Houk RS. Fundamental aspects of ion extraction in inductively coupled plasma mass spectrometry Spectrochimica Acta - Part B Atomic Spectroscopy. 51: 779-815. DOI: 10.1016/0584-8547(96)01506-6 |
0.471 |
|
1996 |
Chen X, Houk R. Spatially resolved measurements of ion density behind the skimmer of an inductively coupled plasma mass spectrometer Spectrochimica Acta Part B: Atomic Spectroscopy. 51: 41-54. DOI: 10.1016/0584-8547(95)01387-3 |
0.443 |
|
1995 |
Chen X, Houk RS. Polyatomic ions as internal standards for matrix corrections in inductively coupled plasma mass spectrometry Journal of Analytical Atomic Spectrometry. 10: 837. DOI: 10.1039/JA9951000837 |
0.353 |
|
1995 |
Allen LA, Pang H, Warren AR, Houk RS. Simultaneous measurement of isotope ratios in solids by laser ablation with a twin quadrupole inductively coupled plasma mass spectrometer Journal of Analytical Atomic Spectrometry. 10: 267. DOI: 10.1039/Ja9951000267 |
0.411 |
|
1995 |
Clemons PS, Minnich MG, Houk RS. Attenuation of Metal Oxide Ions in Inductively Coupled Plasma Mass Spectrometry with a Graphite Torch Injector Analytical Chemistry. 67: 1929-1934. DOI: 10.1021/ac00109a004 |
0.356 |
|
1995 |
Bricker TM, Smith FG, Houk R. Charge transfer reactions between xenon ions and iron atoms in an argon-xenon inductively coupled plasma Spectrochimica Acta Part B: Atomic Spectroscopy. 50: 1325-1335. DOI: 10.1016/0584-8547(95)01357-7 |
0.357 |
|
1995 |
Niu H, Luan S, Pang H, Houk R. Langmuir probe measurements of the ion extraction process in inductively coupled plasma-mass spectrometry. Part 2. Measurements of floating voltage and radiofrequency voltage Spectrochimica Acta Part B: Atomic Spectroscopy. 50: 1247-1261. DOI: 10.1016/0584-8547(95)01331-8 |
0.38 |
|
1995 |
Luan S, Pang H, Houk R. Application of generalized standard additions method to inductively coupled plasma atomic emission spectroscopy with an echelle spectrometer and segmented-array charge-coupled detectors Spectrochimica Acta Part B: Atomic Spectroscopy. 50: 791-801. DOI: 10.1016/0584-8547(94)00159-S |
0.357 |
|
1994 |
Warren AR, Allen LA, Pang H, Houk RS, Janghorbani M. Simultaneous Measurement of Ion Ratios by Inductively Coupled Plasma-Mass Spectrometry with a Twin-Quadrupole Instrument Applied Spectroscopy. 48: 1360-1366. DOI: 10.1366/0003702944027958 |
0.45 |
|
1994 |
Alves LC, Minnich MG, Wiederin DR, Houk RS. Removal of organic solvents by cryogenic desolvation in inductively coupled plasma mass spectrometry. Invited lecture Journal of Analytical Atomic Spectrometry. 9: 399-403. DOI: 10.1039/Ja9940900399 |
0.388 |
|
1994 |
Niu H, Houk RS. Langmuir probe measurements of the ion extraction process in inductively coupled plasma mass spectrometry-I. spatially resolved determination of electron density and electron temperature Spectrochimica Acta Part B: Atomic Spectroscopy. 49: 1283-1303. DOI: 10.1016/0584-8547(94)80109-6 |
0.355 |
|
1993 |
Hu K, Houk RS. Inductively coupled plasma mass spectrometry with an enlarged sampling orifice and offset ion lens. II. Polyatomic Ion interferences and matrix effects. Journal of the American Society For Mass Spectrometry. 4: 28-37. PMID 24234741 DOI: 10.1016/1044-0305(93)85039-Z |
0.376 |
|
1993 |
Hu K, Clemons PS, Houk RS. Inductively coupled plasma mass spectrometry with an enlarged sampling orifice and offset Ion Lens. I. Ion trajectories and detector performance. Journal of the American Society For Mass Spectrometry. 4: 16-27. PMID 24234740 DOI: 10.1016/1044-0305(93)85038-Y |
0.471 |
|
1993 |
Alves LC, Allen LA, Houk RS. Measurement of vanadium, nickel, and arsenic in seawater and urine reference materials by inductively coupled plasma mass spectrometry with cryogenic desolvation. Analytical Chemistry. 65: 2468-71. PMID 8238940 DOI: 10.1021/Ac00066A011 |
0.412 |
|
1993 |
Shum SCK, Johnson SK, Pang H, Houk RS. Spatially Resolved Measurements of Size and Velocity Distributions of Aerosol Droplets from a Direct Injection Nebulizer Applied Spectroscopy. 47: 575-583. DOI: 10.1366/0003702934067108 |
0.328 |
|
1993 |
Shum SCK, Houk RS. Elemental speciation by anion exchange and size exclusion chromatography with detection by inductively coupled plasma mass spectrometry with direct injection nebulization Analytical Chemistry. 65: 2972-2976. DOI: 10.1021/Ac00069A006 |
0.326 |
|
1993 |
Hu K, Houk RS. Inductively coupled plasma mass spectrometry with an enlarged sampling orifice and offset ion lens. II. Polyatomic Ion interferences and matrix effects Journal of the American Society For Mass Spectrometry. 4: 28-37. DOI: 10.1016/1044-0305(93)85039-Z |
0.381 |
|
1993 |
Lim HB, Carney KP, Edelson MC, Houk R, Brenner I. Extraction discharge source for inductively coupled plasma atomic emission spectrometry: spectral linewidths and interference effects Spectrochimica Acta Part B: Atomic Spectroscopy. 48: 1617-1623. DOI: 10.1016/0584-8547(93)80147-M |
0.355 |
|
1992 |
Shum SC, Pang HM, Houk RS. Speciation of mercury and lead compounds by microbore column liquid chromatography-inductively coupled plasma mass spectrometry with direct injection nebulization. Analytical Chemistry. 64: 2444-50. PMID 19827823 DOI: 10.1021/Ac00044A025 |
0.416 |
|
1992 |
Shum SC, Neddersen R, Houk RS. Elemental speciation by liquid chromatography-inductively coupled plasma mass spectrometry with direct injection nebulization. The Analyst. 117: 577-82. PMID 1580404 DOI: 10.1039/An9921700577 |
0.41 |
|
1992 |
Alves LC, Wiederin DR, Houk RS. Reduction of polyatomic ion interferences in inductively coupled plasma mass spectrometry by cryogenic desolvation Analytical Chemistry. 64: 1164-1169. DOI: 10.1021/ac00034a016 |
0.368 |
|
1991 |
Wiederin DR, Houk RS. Measurements of Aerosol Particle Sizes from a Direct Injection Nebulizer Applied Spectroscopy. 45: 1408-1412. DOI: 10.1366/0003702914335481 |
0.314 |
|
1991 |
Winge RK, Crain JS, Houk RS. High speed photographic study of plasma fluctuations and intact aerosol particles or droplets in inductively coupled plasma mass spectrometry Journal of Analytical Atomic Spectrometry. 6: 601. DOI: 10.1039/Ja9910600601 |
0.401 |
|
1991 |
Wiederin DR, Smyczek RE, Houk RS. On-line standard additions with direct injection nebulization for inductively coupled plasma mass spectrometry Analytical Chemistry. 63: 1626-1631. DOI: 10.1021/Ac00015A024 |
0.389 |
|
1991 |
Smith FG, Wiederin DR, Houk RS. Argon-xenon plasma for alleviating polyatomic ion interferences in inductively coupled plasma mass spectrometry Analytical Chemistry. 63: 1458-1462. DOI: 10.1021/ac00014a021 |
0.341 |
|
1991 |
Pang HM, Wiederin DR, Houk RS, Yeung ES. High-repetition-rate laser ablation for elemental analysis in an inductively coupled plasma with acoustic wave normalization Analytical Chemistry. 63: 390-394. DOI: 10.1021/Ac00004A017 |
0.418 |
|
1991 |
Wiederin DR, Smith FG, Houk RS. Direct injection nebulization for inductively coupled plasma mass spectrometry Analytical Chemistry. 63: 219-225. DOI: 10.1021/Ac00003A007 |
0.404 |
|
1991 |
Smith FG, Wiederin DR, Houk R, Egan CB, Serfass RE. Measurement of boron concentration and isotope ratios in biological samples by inductivey coupled plasma mass spectrometry with direct injection nebulization Analytica Chimica Acta. 248: 229-234. DOI: 10.1016/S0003-2670(00)80889-2 |
0.395 |
|
1991 |
Niu H, Hu K, Houk R. Langmuir probe measurements of electron temperature and electron density behind the skimmer of an inductively coupled plasma mass spectrometer Spectrochimica Acta Part B: Atomic Spectroscopy. 46: 805-817. DOI: 10.1016/0584-8547(91)80082-E |
0.397 |
|
1991 |
Houk R, Shum S, Wiederin D. Frontiers in elemental analysis by mass spectrometry Analytica Chimica Acta. 250: 61-70. DOI: 10.1016/0003-2670(91)85062-W |
0.42 |
|
1990 |
Smith FG, Houk RS. Alleviation of polyatomic ion interferences for determination of chlorine isotope ratios by inductively coupled plasma mass spectrometry. Journal of the American Society For Mass Spectrometry. 1: 284-7. PMID 24248820 DOI: 10.1016/1044-0305(90)85002-4 |
0.443 |
|
1990 |
Schoer JK, Houk RS, Conzemius RJ, Schrader GL. Ion association by time-of-flight mass spectrometry: a study of V-P-O catalysts. Journal of the American Society For Mass Spectrometry. 1: 129-37. PMID 24248740 DOI: 10.1016/1044-0305(90)85048-Q |
0.41 |
|
1990 |
Wiederin DR, Houk RS, Winge RK, D'Silva AP. Introduction of organic solvents into inductively coupled plasmas by ultrasonic nebulization with cryogenic desolvation Analytical Chemistry. 62: 1155-1160. DOI: 10.1021/Ac00210A012 |
0.327 |
|
1990 |
Lim H, Houk R. Langmuir probe measurement of electron temperature in a supersonic jet extracted from an inductively coupled plasma Spectrochimica Acta Part B: Atomic Spectroscopy. 45: 453-461. DOI: 10.1016/0584-8547(90)80121-X |
0.328 |
|
1990 |
Crain JS, Smith FG, Houk R. Mass spectrometric measurement of ionization temperature in an inductively coupled plasma Spectrochimica Acta Part B: Atomic Spectroscopy. 45: 249-259. DOI: 10.1016/0584-8547(90)80101-N |
0.416 |
|
1989 |
Rowan JT, Houk RS. Attenuation of Polyatomic Ion Interferences in Inductively Coupled Plasma Mass Spectrometry by Gas-Phase Collisions Applied Spectroscopy. 43: 976-980. DOI: 10.1366/0003702894204065 |
0.421 |
|
1989 |
Lim HB, Houk RS, Edelson MC, Carney KP. Some fundamental characteristics of a reduced-pressure plasma extracted from an inductively coupled plasma Journal of Analytical Atomic Spectrometry. 4: 365. DOI: 10.1039/Ja9890400365 |
0.429 |
|
1989 |
Plantz MR, Fritz JS, Smith FG, Houk RS. Separation of trace metal complexes for analysis of samples of high salt content by inductively coupled plasma mass spectrometry Analytical Chemistry. 61: 149-153. DOI: 10.1021/Ac00177A014 |
0.412 |
|
1989 |
Lim H, Houk R, Crain JS. Langmuir probe measurements of potential inside a supersonic jet extracted from an inductively coupled plasma Spectrochimica Acta Part B: Atomic Spectroscopy. 44: 989-998. DOI: 10.1016/0584-8547(89)80099-0 |
0.465 |
|
1989 |
Huang L, Conzemius R, Junk G, Houk R. Ion association by time-of-flight mass spectrometry International Journal of Mass Spectrometry and Ion Processes. 90: 85-96. DOI: 10.1016/0168-1176(89)83055-1 |
0.437 |
|
1989 |
Conzemius RJ, Junk GA, Houk RS, Adduci D, Huang LQ. An instrument control and data acquisition system for time-of-flight measurements of low ion current pulses International Journal of Mass Spectrometry and Ion Processes. 90: 281-293. DOI: 10.1016/0168-1176(89)80073-4 |
0.419 |
|
1989 |
Chang H, Johnson D, Houk R. In situ coupling between electrochemistry and mass spectrometry — a literature review Trac Trends in Analytical Chemistry. 8: 328-333. DOI: 10.1016/0165-9936(89)87039-6 |
0.304 |
|
1988 |
Huang LQ, Conzemius RJ, Holland GE, Houk RS. Reduction of signal reflections for fast-pulse recording with microchannel plate detectors Analytical Chemistry. 60: 1635-1637. DOI: 10.1021/Ac00166A035 |
0.389 |
|
1988 |
Huang LQ, Conzemius RJ, Junk GA, Houk RS. Laser desorption time-of-flight mass spectrometry using a 300-ps ultraviolet laser Analytical Chemistry. 60: 1490-1494. DOI: 10.1021/Ac00166A003 |
0.338 |
|
1988 |
LaFreniere BR, Houk RS, Wiederin DR, Fassel VA. Direct detection of vacuum ultraviolet radiation through an optical sampling orifice: determination of nonmetals in gaseous samples by inductively coupled plasma atomic emission spectroscopy Analytical Chemistry. 60: 23-26. DOI: 10.1021/Ac00152A007 |
0.626 |
|
1988 |
Grain JS, Houk† R, Smith FG. Matrix interferences in inductively coupled plasma-mass spectrometry: some effects of skimmer orifice diameter and ion lens voltages Spectrochimica Acta Part B: Atomic Spectroscopy. 43: 1355-1364. DOI: 10.1016/0584-8547(88)80175-7 |
0.44 |
|
1988 |
Jiang S, Houk R. Inductively coupled plasma mass spectrometric detection for phosphorus and sulfur compounds separated by liquid chromatography Spectrochimica Acta Part B: Atomic Spectroscopy. 43: 405-411. DOI: 10.1016/0584-8547(88)80068-5 |
0.355 |
|
1988 |
Pei-Qi L, Pei-Zhong G, Tie-Zheng L, Houk R. Langmuir probe measurements of electron temperature in an inductively coupled plasma Spectrochimica Acta Part B: Atomic Spectroscopy. 43: 273-285. DOI: 10.1016/0584-8547(88)80053-3 |
0.302 |
|
1987 |
Chong NS, Houk RS. Inductively Coupled Plasma-Mass Spectrometry for Elemental Analysis and Isotope Ratio Determinations in Individual Organic Compounds Separated by Gas Chromatography Applied Spectroscopy. 41: 66-74. DOI: 10.1366/0003702874867963 |
0.395 |
|
1987 |
Houk RS, Lafreniere BR, Lim HB, Fassel VA. Extraction Discharge Source for Enhancing Analyte Line Intensities in Inductively Coupled Plasma Atomic Emission Spectrometry Applied Spectroscopy. 41: 391-395. DOI: 10.1366/0003702874448823 |
0.396 |
|
1987 |
Huang LQ, Conzemius RJ, Houk RS. Relative Ionization Yields for Impurity Elements in Laser Mass Spectrometry of Steels and Brasses Applied Spectroscopy. 41: 667-670. DOI: 10.1366/0003702874448715 |
0.386 |
|
1987 |
Thompson JJ, Houk RS. A Study of Internal Standardization in Inductively Coupled Plasma-Mass Spectrometry Applied Spectroscopy. 41: 801-806. DOI: 10.1366/0003702874448265 |
0.388 |
|
1987 |
Houk RS, Schoer JK, Crain JS. Plasma potential measurements for inductively coupled plasma mass spectrometry with a centre-tapped load coil Journal of Analytical Atomic Spectrometry. 2: 283. DOI: 10.1039/Ja9870200283 |
0.419 |
|
1987 |
Gray AL, Houk RS, Williams JG. Langmuir probe potential measurements in the plasma and their correlation with mass spectral characteristics in inductively coupled plasma mass spectrometry Journal of Analytical Atomic Spectrometry. 2: 13-20. DOI: 10.1039/Ja9870200013 |
0.459 |
|
1987 |
Huang LQ, Jiang SJ, Houk RS. Scintillation-type ion detection for inductively coupled plasma mass spectrometry Analytical Chemistry. 59: 2316-2320. DOI: 10.1021/ac00145a022 |
0.346 |
|
1987 |
LaFreniere BR, Houk RS, Fassel VA. Direct detection of vacuum ultraviolet radiation through an optical sampling orifice: analytical figures of merit for the nonmetals, metalloids, and selected metals by inductively coupled plasma atomic emission spectrometry Analytical Chemistry. 59: 2276-2282. DOI: 10.1021/Ac00145A015 |
0.61 |
|
1987 |
Jiang S, Palmieri M, Fritz J, Houk R. Chromatographic retention of molybdenum, titanium and uranium complexes for removal of some interference in inductively-coupled plasma mass spectrometry Analytica Chimica Acta. 200: 559-571. DOI: 10.1016/S0003-2670(00)83801-5 |
0.377 |
|
1987 |
Jiang S, Houk R. Elemental and isotopic analysis of powders by inductively coupled plasma mass spectrometry with arc nebulization Spectrochimica Acta Part B: Atomic Spectroscopy. 42: 93-100. DOI: 10.1016/0584-8547(87)80052-6 |
0.464 |
|
1986 |
Houk RS, Fassel VA, Lafreniere BR. Direct Detection of Vacuum Ultraviolet Radiation through an Optical Sampling Orifice: Spatially Resolved Emission Studies of Argon Resonance Lines from an Inductively Coupled Plasma Applied Spectroscopy. 40: 94-100. DOI: 10.1366/0003702864815493 |
0.607 |
|
1986 |
Olivares JA, Houk RS. Suppression of analyte signal by various concomitant salts in inductively coupled plasma mass spectrometry Analytical Chemistry. 58: 20-25. DOI: 10.1021/Ac00292A008 |
0.453 |
|
1986 |
Houk RS. Mass spectrometry of inductively coupled plasmas Analytical Chemistry. 58: 97A-105A. DOI: 10.1021/Ac00292A003 |
0.439 |
|
1986 |
Houk RS, Lim HB. Atomic emission spectrometry with a reduced-pressure afterglow extracted from an inductively coupled plasma Analytical Chemistry. 58: 3244-3248. DOI: 10.1021/Ac00127A072 |
0.34 |
|
1986 |
Jiang SJ, Houk RS. Arc nebulization for elemental analysis of conducting solids by inductively coupled plasma mass spectrometry Analytical Chemistry. 58: 1739-1743. DOI: 10.1021/Ac00121A031 |
0.489 |
|
1986 |
Palmieri MD, Fritz JS, Thompson JJ, Houk RS. Separation of trace rare earths and other metals from uranium by liquid-liquid extraction with quantitation by inductively-coupled plasma/mass spectrometry Analytica Chimica Acta. 184: 187-196. DOI: 10.1016/S0003-2670(00)86481-8 |
0.334 |
|
1986 |
Serfass RE, Thompson JJ, Houk RS. Isotope ratio determinations by inductively coupled plasma/mass spectrometry for zinc bioavailability studies Analytica Chimica Acta. 188: 73-84. DOI: 10.1016/S0003-2670(00)86031-6 |
0.431 |
|
1985 |
Olivares JA, Houk RS. Kinetic Energy Distributions of Positive Ions in an Inductively Coupled Plasma Mass Spectrometer Applied Spectroscopy. 39: 1070-1077. DOI: 10.1366/0003702854249547 |
0.431 |
|
1985 |
Olivares JA, Houk RS. Ion sampling for inductively coupled plasma mass spectrometry Analytical Chemistry. 57: 2674-2679. DOI: 10.1021/Ac00290A054 |
0.48 |
|
1984 |
Houk RS, Olivares JA. General calculations of vertically-resolved emission profiles for analyte elements in inductively coupled plasmas Spectrochimica Acta Part B: Atomic Spectroscopy. 39: 575-587. DOI: 10.1016/0584-8547(84)80065-8 |
0.399 |
|
1984 |
Conzemius RJ, Zhao S, Houk RS, Svec HJ. Effect of laser focus on ion production in the laser ion source for elemental analysis International Journal of Mass Spectrometry and Ion Processes. 61: 277-292. DOI: 10.1016/0168-1176(84)87101-3 |
0.628 |
|
1983 |
Houk RS, Montaser A, Fassel VA. Mass Spectra and Ionization Temperatures in an Argon-Nitrogen Inductively Coupled Plasma Applied Spectroscopy. 37: 425-428. DOI: 10.1366/0003702834634848 |
0.361 |
|
1983 |
Houk RS, Thompson JJ. Trace metal isotopic analysis of microliter solution volumes by inductively coupled plasma mass spectrometry Biological Mass Spectrometry. 10: 107-112. DOI: 10.1002/Bms.1200100212 |
0.456 |
|
1982 |
Houk RS, Fassel VA, Svec HJ. Mass spectra of polar organic compounds in aqueous solutions introduced into an inductively coupled plasma Organic Mass Spectrometry. 17: 240-244. DOI: 10.1002/Oms.1210170509 |
0.744 |
|
1981 |
Houk RS, Svec HJ, Fassel VA. MASS SPECTROMETRIC EVIDENCE FOR SUPRATHERMAL IONIZATION IN AN INDUCTIVELY COUPLED ARGON PLASMA Applied Spectroscopy. 35: 380-384. DOI: 10.1366/0003702814732391 |
0.758 |
|
1980 |
Houk RS, Fassel VA, Flesch GD, Svec HJ, Gray AL, Taylor CE. Inductively coupled argon plasma as an ion source for mass spectrometric determination of trace elements Analytical Chemistry. 52: 2283-2289. DOI: 10.1021/Ac50064A012 |
0.701 |
|
Low-probability matches (unlikely to be authored by this person) |
1988 |
Jiang SJ, Houk RS, Stevens MA. Alleviation of overlap interferences for determination of potassium isotope ratios by inductively coupled plasma mass spectrometry Analytical Chemistry. 60: 1217-1221. DOI: 10.1021/ac00162a023 |
0.295 |
|
1997 |
Gwizdala AB, Johnson SK, Mollah S, Houk RS. Speciation of chromium(VI) and chromium(III) using pneumatically assisted electrospray mass spectrometry Journal of Analytical Atomic Spectrometry. 12: 503-506. DOI: 10.1039/A606413B |
0.295 |
|
2002 |
Sung Y, Lim HB, Houk RS. Diagnostic studies of a low-pressure inductively coupled plasma in argon using a double Langmuir probe Journal of Analytical Atomic Spectrometry. 17: 565-569. DOI: 10.1039/B110219M |
0.293 |
|
1986 |
Thompson JJ, Houk RS. Inductively coupled plasma mass spectrometric detection for multielement flow injection analysis and elemental speciation by reversed-phase liquid chromatography Analytical Chemistry. 58: 2541-2548. DOI: 10.1021/Ac00125A039 |
0.293 |
|
1998 |
Amad MH, Houk RS. High-resolution mass spectrometry with a multiple pass quadrupole mass analyzer. Analytical Chemistry. 70: 4885-9. PMID 21644671 DOI: 10.1021/ac980505w |
0.292 |
|
1987 |
Houk R, Schoer J, Crain J. Deduction of arbitrary excitation temperatures for various analyte species in inductively coupled plasmas from vertically-resolved emission profiles Spectrochimica Acta Part B: Atomic Spectroscopy. 42: 841-852. DOI: 10.1016/0584-8547(87)80145-3 |
0.291 |
|
1996 |
LaFreniere BR, Wiederin DR, Fassel VA, Houk R. Molecular hydrogen emission in the vacuum ultraviolet from an inductively coupled plasma Spectrochimica Acta Part B: Atomic Spectroscopy. 51: 3-12. DOI: 10.1016/0584-8547(95)01347-4 |
0.29 |
|
1994 |
Houk RS. Elemental and isotopic analysis by inductively coupled plasma mass spectrometry Accounts of Chemical Research. 27: 333-339. DOI: 10.1021/ar00047a003 |
0.288 |
|
2014 |
Anderson TJ, Jones RW, Ai Y, Houk RS, Jane JL, Zhao Y, Birt DF, McClelland JF. High-resolution time-of-flight mass spectrometry fingerprinting of metabolites from cecum and distal colon contents of rats fed resistant starch. Analytical and Bioanalytical Chemistry. 406: 745-56. PMID 24306331 DOI: 10.1007/S00216-013-7523-8 |
0.288 |
|
1987 |
Serfass RE, Lindberg GL, Olivares JA, Houk RS. Intrinsic labeling of bovine milk with enriched stable isotopes of zinc. Proceedings of the Society For Experimental Biology and Medicine. Society For Experimental Biology and Medicine (New York, N.Y.). 186: 113-7. PMID 3628249 DOI: 10.3181/00379727-186-1-Rc1 |
0.283 |
|
2000 |
Houk RS. Inductively Coupled Plasma-Mass Spectrometry and the European Discovery of America Journal of Chemical Education. 77: 598. DOI: 10.1021/ed077p598 |
0.278 |
|
1992 |
Luan S, Pang H, Shum SCK, Houk RS. Noise characteristics of aerosols produced by inductively coupled plasma nebulizers Journal of Analytical Atomic Spectrometry. 7: 799. DOI: 10.1039/Ja9920700799 |
0.269 |
|
2015 |
Jesche A, Ke L, Jacobs JL, Harmon B, Houk RS, Canfield PC. Alternating magnetic anisotropy of Li2(Li1-xTx) N (T=Mn, Fe, Co, and Ni) Physical Review B - Condensed Matter and Materials Physics. 91. DOI: 10.1103/Physrevb.91.180403 |
0.266 |
|
1989 |
Ziegler EE, Serfass RE, Nelson SE, Figueroa-Colón R, Edwards BB, Houk RS, Thompson JJ. Effect of low zinc intake on absorption and excretion of zinc by infants studied with 70Zn as extrinsic tag. The Journal of Nutrition. 119: 1647-53. PMID 2600669 DOI: 10.1093/Jn/119.11.1647 |
0.263 |
|
1997 |
Minnich MG, Houk RS, Woodin MA, Christiani DC. Method to Screen Urine Samples for Vanadium by Inductively Coupled Plasma Mass Spectrometry With Cryogenic Desolvation Journal of Analytical Atomic Spectrometry. 12: 1345-1350. DOI: 10.1039/A700172J |
0.262 |
|
2000 |
Praphairaksit N, Houk RS. Attenuation of matrix effects in inductively coupled plasma mass spectrometry with a supplemental electron source inside the skimmer Analytical Chemistry. 72: 2351-5. PMID 10857604 |
0.261 |
|
1989 |
Serfass RE, Ziegler EE, Edwards BB, Houk RS. Intrinsic and extrinsic stable isotopic zinc absorption by infants from formulas. The Journal of Nutrition. 119: 1661-9. PMID 2600671 DOI: 10.1093/Jn/119.11.1661 |
0.26 |
|
1994 |
Alves LC, Minnich MG, Wiederin DR, Houk RS. Removal of organic solvents by cryogenic desolvation in inductively coupled plasma mass spectrometry. Invited lecture Journal of Analytical Atomic Spectrometry. 9: 399. DOI: 10.1039/JA9940900399 |
0.258 |
|
1991 |
Egan CB, Smith FG, Houk RS, Serfass RE. Zinc absorption in women: comparison of intrinsic and extrinsic stable-isotope labels. The American Journal of Clinical Nutrition. 53: 547-53. PMID 1989425 DOI: 10.1093/Ajcn/53.2.547 |
0.249 |
|
2018 |
Wang G, Manni S, Lin Q, McVey P, Houk RS, Wu L, Bud’ko SL, Canfield PC. An inverse Ruddlesden-Popper nitride Ca7(Li1−xFex)Te2N2 grown from Ca flux Philosophical Magazine Letters. 98: 118-125. DOI: 10.1080/09500839.2018.1497309 |
0.247 |
|
1985 |
Houk R. Model for measuring excitation temperatures on a relative basis without transition probabilities Spectrochimica Acta Part B: Atomic Spectroscopy. 40: 1517-1524. DOI: 10.1016/0584-8547(85)80175-0 |
0.245 |
|
2009 |
Ferguson JW, Dudley TJ, Sears KC, McIntyre SM, Gordon MS, Houk RS. Polyatomic ions in inductively coupled plasma-mass spectrometry. Part II: Origins of N2H+ and HxCO+ ions using experimental measurements combined with calculated energies and structures Spectrochimica Acta - Part B Atomic Spectroscopy. 64: 690-696. DOI: 10.1016/J.Sab.2009.06.008 |
0.238 |
|
2009 |
Lorge SE, Houk R. Controlled dissolution of silicon dioxide layers for depth resolved multielement analysis by inductively coupled plasma-mass spectrometry Spectrochimica Acta Part B: Atomic Spectroscopy. 64: 1235-1239. DOI: 10.1016/J.SAB.2009.09.007 |
0.234 |
|
2013 |
Anderson TJ, Ai Y, Jones RW, Houk RS, Jane JL, Zhao Y, Birt DF, McClelland JF. Analysis of resistant starches in rat cecal contents using Fourier transform infrared photoacoustic spectroscopy. Journal of Agricultural and Food Chemistry. 61: 1818-22. PMID 23360415 DOI: 10.1021/Jf3042616 |
0.22 |
|
1989 |
Crain JS, Houk RS, Eckels DE. Noise power spectral characteristics of an inductively coupled plasma-mass spectrometer Analytical Chemistry. 61: 606-612. DOI: 10.1021/ac00181a022 |
0.209 |
|
2014 |
Jesche A, McCallum RW, Thimmaiah S, Jacobs JL, Taufour V, Kreyssig A, Houk RS, Bud'ko SL, Canfield PC. Giant magnetic anisotropy and tunnelling of the magnetization in Li₂(Li(1-x)Fe(x))N. Nature Communications. 5: 3333. PMID 24566374 DOI: 10.1038/Ncomms4333 |
0.208 |
|
1998 |
Houk RS. Plasma Source Mass Spectrometry: Developments and Applications Edited by Grenville Holland (University of Durham) and Scott D. Tanner (PE-Sciex). American Chemical Society: Washington, DC. 1997. x + 329 pp. $136.00. ISBN 0-85404-727-1. Journal of the American Chemical Society. 120: 8291-8291. DOI: 10.1021/ja975652a |
0.185 |
|
2007 |
Houk RS, Grayson MA, Gross ML. Harry J. Svec June 24, 1918–November 28, 2006 Journal of the American Society For Mass Spectrometry. 18: 970-971. DOI: 10.1016/J.Jasms.2007.02.002 |
0.178 |
|
1998 |
Amad MH, Houk RS. A secondary discharge intensifies optical emission from a Mach disk extracted from an inductively coupled plasma Journal of Analytical Atomic Spectrometry. 13: 223-228. DOI: 10.1039/A704272H |
0.177 |
|
1993 |
Houk R. Plasma source mass spectrometry Edited by K.E. Jarvis,A.L. Gray,I. Jarvis and J. Williams Royal society of chemistry, cambridge, CB4 4WF, UK Purchased by CRC Press, INC., 2000 Corporate Boulevard, NW, Boca Raton, FL 33431, (407) 994-0555 ISBN 0-85186-567-4 1990,$95.00 Journal of the American Society For Mass Spectrometry. 4: 428-428. DOI: 10.1016/1044-0305(93)85009-M |
0.177 |
|
1993 |
Houk RS. Atomic spectrometry viewpoint Journal of Analytical Atomic Spectrometry. 8: 2N. DOI: 10.1039/JA993080002N |
0.101 |
|
2001 |
Su H, Hou Y, Houk RS, Schrader GL, Yeung ES. Combinatorial screening of heterogeneous catalysis in selective oxidation of naphthalene by laser-induced fluorescence imaging. Analytical Chemistry. 73: 4434-40. PMID 11575790 DOI: 10.1021/Ac015513I |
0.086 |
|
1989 |
Flescher E, Bowlin TL, Ballester A, Houk R, Talal N. Increased polyamines may downregulate interleukin 2 production in rheumatoid arthritis. The Journal of Clinical Investigation. 83: 1356-62. PMID 2784801 DOI: 10.1172/JCI114023 |
0.034 |
|
2001 |
Houk R. Velmer Arthur Fassel 1919–1998 Spectrochimica Acta Part B: Atomic Spectroscopy. 56: 1035. DOI: 10.1016/S0584-8547(01)00257-9 |
0.021 |
|
2010 |
Houk RS. Thirty years ago this month… Journal of Analytical Atomic Spectrometry. 25: 1801. DOI: 10.1039/C0JA00186D |
0.01 |
|
2001 |
Houk R. Studying with Velmer Fassel — the later years Spectrochimica Acta Part B: Atomic Spectroscopy. 56: 1047-1050. DOI: 10.1016/S0584-8547(01)00259-2 |
0.01 |
|
Hide low-probability matches. |